A methodological approach and the basic tenets for evaluating the reliability of in-reactor monitoring of VVER are presented. The method is based on the statistical analysis of indications in real time and includes methods for evaluating the admissible maximum error of the measurement channels used for monitoring as well as the average value and admissible deviation of indications in groups of parallel monitoring channels, as well as a method of evaluating reliability by comparing the values of a parameter with the regime values. In comparing the indications of a monitoring channel with the indications of other parallel channels, the median value is proposed as the baseline value. The developed method is implemented in the Diagnostika SVRK special software, which has been successfully tested during the commissioning of the No. 1 unit at the Novovoronezh NPP-2.
Similar content being viewed by others
References
A. E. Kalinushkin, V. V. Kozlov, V. I. Mitin, and Yu. M. Semchenkov, “Monitoring, diagnostics, and control system for high-power nuclear power installations with water moderated and cooled reactors,” At. Energ., 106, No. 1, 3–8 (2009).
NP-001-15, General Safety Tenets for Nuclear Power Plants, Moscow (2015).
On-Line Monitoring for Improving Performance of Nuclear Power Plants. Pt 1. Instrument Channel Monitoring, IAEA, Vienna (2008).
On-Line Monitoring for Improving Performance of Nuclear Power Plants. Pt 2. Process and Component Condition Monitoring and Diagnostics, IAEA, Vienna (2008).
Kh. M. Khashemian, Technical Maintenance of Measuring Devices in Nuclear Power Plants, Izd. BINOM, Moscow (2012).
R. V. Alyev, Identification of the State of the Core and Analysis of the Reliability of Information from the In-Reactor Monitoring System during Operation of VVER-1000 Fuel Loads: Auth. Abstr. Dissert. Cand. Techn. Sci., MIPhI, Obninsk (2013).
A. V. Semennikhin, Yu. V. Saunin, and M. N. Zhuk, “Testing of the SVRK information diagnostics system in the No. 1 unit of Novovoronezh NPP-2,” in: Abstr. 10th Int. Sci. Techn. Conf. on Safety Security of NPP with VVER, Podolsk, May 16–19, 2017, p. 98.
Yu. V. Saunin, A. N. Dobrotvorskii, and A. V. Semenikhin, “Development and application of specialized software in performing complex tests of an in-reactor monitoring system for VVER reactors,” Tyazh. Mashinostr., No. 11, 18–22 (2008).
Yu. V. Saunin, Development of Methods for Complex Testing of In-Reactor Monitoring Systems for VVER: Auth. Abstr. Dissert. Cand. Techn. Sci., UPTI, Ekaterinburg (2010).
RMG 62–2003, Guaranteeing Measurement Efficiency in Controlling Technological Processes. Evaluation of Measurement Error with Limited Initial Information, Izd. Standartov, Moscow (2004).
Yu. V. Saunin, A. N. Dobrotvorski, A. V. Semenikhin, et al., “Numerical and experimental investigation of 3D coolant temperature distribution in the hot legs of primary circuit of reactor plant with WWER-1000,” Kerntechnik, 80, No. 4, 366–372 (2015).
Author information
Authors and Affiliations
Additional information
Translated from Atomnaya Énergiya, Vol. 124, No. 1, pp. 8–13, January, 2018.
Rights and permissions
About this article
Cite this article
Semenikhin, A.V., Saunin, Y.V. & Ryasnyi, S.I. Method of Determining the Reliability of Real-Time In-reactor Monitoring of VVER. At Energy 124, 8–13 (2018). https://doi.org/10.1007/s10512-018-0367-8
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10512-018-0367-8