Introduction

Electronic nicotine device systems, commonly known as electronic (e-) cigarettes, or vapes, are battery-powered devices that deliver vapor containing a flavoring component and nicotine. These products officially entered the U.S. marketplace in 2007 and since then, their use has rapidly increased due to their popularity among the younger generations [1]. While e-cigarettes are often marketed as a safer alternative to traditional cigarettes [2], their impact on cardiovascular health is still a topic of active research.

The association between traditional tobacco use and increased cardiovascular risk is well-documented, with tobacco being recognized as one of the major contributors to heart disease. Early observations, primarily from preclinical models, have linked e-cigarette usage with different cardiovascular disease risk markers [3,4,5]. More recent studies have also shown that acute exposure to e-cigarettes may impact cardiovascular health in humans [6, 7] causing reduced vascular function [8,9,10] and an associated increase in oxidative damage [8, 11]. Comparable results have also been identified in the macrovasculature of chronic adult users of e-cigarettes, with a similar dysfunction as that observed in traditional tobacco users [12], although opposite results have been also described [13,14,15].

Microvascular function plays a pivotal role in cardiovascular health and dysfunctions in the microcirculation are considered among the earliest indicators of cardiovascular disease risk that can be identified prior to traditional clinical markers [16]. In fact, microvascular dysfunction is a crucial mechanism in the development and progression of cardiovascular disease and often precedes other macrovascular pathological processes [17, 18]. A recent study has shown reduced microvascular function, particularly endothelium-dependent, in chronic users of e-cigarettes [19]. Despite these early findings, the regular effects of e-cigarette usage on vascular function are still not yet well understood. Thus, this study aims to investigate the relationship between micro and macrovascular function, cardiovascular health, and e-cigarette usage in young adults. We hypothesized that regular users of e-cigarettes, who are otherwise healthy young adults, will exhibit reduced micro- and macrovascular function when compared to demographically matched non-users.

Material and methods

Experimental design

Volunteers presented to the Vascular and Integrative Physiology (VIP) Laboratory on two separate occasions: a preliminary day and an experimental day. The preliminary day consisted of assessing body composition, blood pressure, medical history, and overall health status. For the experimental day, participants reported to the VIP Laboratory following an overnight fast, having abstained from e-cigarette usage and caffeine for 12 h, vigorous physical activity for 24 h, and vitamin supplementation for 72 h. Vascular health through evaluation of macro- and microvascular function was completed.

Participants

A total of forty-two young adult men and women, ages 21–31 years were enrolled in the present study, following the principles of the Declaration of Helsinki and after approval by the Institutional Review Board at Virginia Commonwealth University. Among the participants, 21 young adults were regular users of e-cigarettes (≥ 3 times/week for ≥ 3 months) while 21 young adults were non-users demographically matched considering age, sex, and body mass index. Participants from both groups were excluded if they used (1) cigarettes or other tobacco products (cigars, hookahs, smokeless) in the past 60 days, (2) any illicit or prescription drugs for non-medical used weekly or more frequently in the past 60 days, (3) were diagnosed with any cardiovascular, pulmonary, renal, hepatic, metabolic, and cerebral diseases, or (4) were currently pregnant or nursing.

Participants completed self-reported questionnaires, including the Short Form Vaping Consequences Questionnaire, E-Cigarette Dependent Scale, and the NIDA Quick Screen to report type of e-cigarette products or usage of other tobacco products as well as alcohol and drug use. Out of 21 regular users of e-cigarettes, 20 self-identified as sole users of e-cigarettes, never smokers, primarily using fourth generation e-cigarettes. All participants were informed of the objectives, and possible risks of the investigation before written consent for participation was obtained.

Demographic characteristics

Demographic characteristics were evaluated in all the participants during the preliminary visit. Volunteers completed a standard anthropometric assessment of height, weight, and calculated body mass index (BMI). A self-reported evaluation of e-cigarette usage was obtained from each participant using the E-Cigarette Dependence Scale [20] and the Penn State Electronic Cigarette Dependence Index [21].

Clinical laboratory values

A venous blood sample was collected for the assessment of a complete blood count and a comprehensive metabolic panel by standard core laboratory techniques (Laboratory Corporation of America Holdings, Burlington, NC). Fasting concentrations of lipids (total cholesterol (TC), high-density lipoproteins (HDL), low-density lipoproteins (LDL), and triglycerides) and glucose were obtained using the Cholestech LDX analyzer (Alere, Providence, RI). Hemoglobin and hematocrit values were obtained using the HemoPoint H2 analyzer (Stanbio Laboratory, Boerne, TX).

Microvascular function

Microvascular function was evaluated using a laser speckle contrast imager (MoorFLPI2, Moor Instruments, DE) of the cutaneous circulation of the forearm. Briefly, the right arm of each participant was extended laterally, and the distal forearm was secured in a vacuum-packed pillow (Vacpac, MD). A forearm cuff was placed immediately distal to the medial epicondyle, and three chambers were placed on the ventral surface of the forearm. The placement was carefully selected, avoiding any area with hair, broken skin, areas of skin pigmentation (or tattoos), and visible veins.

After a 20 min acclimation period and in a temperature-controlled room (22 ± 2 °C) to achieve a hemodynamic steady state, baseline (BL) flux was determined by calculating a 30-s average. A biological zero (B0), to control for the Brownian movement of macromolecules in cutaneous interstitial space, was also determined during a reduction of blood flow in the forearm and subtracted from both baseline and peak responses. Then, four different reactivity tests and control were completed:

  1. (1)

    Local thermal hyperemia (LTH) was completed to determine maximal microvascular dilation [22] in all the participants. A chamber (Moor VHP3) was attached to the volar surface of the forearm and filled with 2 ml of deionized water and heated at > 0.1 °C/s to 44 °C for 25 min [22]. This protocol elicits a biphasic response with an initial dilation primarily mediated by axon reflex [23] and a second dilation primarily mediated by nitric oxide [23] and endothelial-derived hyperpolarization factors (EDHF) [24]. Maximal dilation achieved during this protocol was used to compare the relative response to other protocols [23]. All variables related to this protocol are defined with the subscript LTH.

  2. (2)

    Post-occlusive reactive hyperemia (PORH) was completed in all the participants to evaluate microvascular shear-stress response primarily mediated by sensory nerves and EDHF [25, 26]. A forearm cuff was inflated to 250 mmHg for 5 min. After the occlusion period, the release of the pressure elicited a hyperemic response. All variables related to this protocol are defined with the subscript PORH.

  3. (3)

    Iontophoresis of acetylcholine (ACh) to assess microvascular endothelial-dependent vasodilation through nitric oxide, EDHF, and prostaglandins mediators [22, 27]. A chamber with an internal platinum wire electrode (Moor MIC-ION 6) was attached to the skin of the volar aspect of the forearm by a double-sided adhesive disk filled with a solution of 2% ACh in 0.5% NaCl. The drug was delivered in the dermis using an incremental current delivery with three scans of 20 s at 5 µA, 10 µA, 15 µA, 20 µA, and 25 µA, giving a total charge of 4.5 mC. Short scan times and low currents were used to minimize non-specific vasodilation [22, 28]. All variables related to this protocol are defined with the subscript ACH. Due to technical issues, all participants minus two from the ECU group completed this test.

  4. (4)

    Iontophoresis of sodium nitroprusside (SNP) to evaluate microvascular endothelial-independent response through the delivery of nitric oxide to the smooth muscle cells [29]. A second chamber with an internal platinum wire electrode (Moor MIC-ION 6) was also attached to the volar aspect of the forearm. A solution of 2% SNP in 0.5% NaCl was used and delivered to the dermis using the same protocol previously described for Ach. All variables related to this protocol are defined with the subscript SNP. Due to technical issues with the delivery chamber, sixteen participants from the ECU and eighteen from the NU group completed this test.

  5. (5)

    A non-reactive site was monitored as a control site all the participants. An arbitrary area of the skin between the three chambers was used to evaluate non-specific vasodilation and/or movement for 30 min. All variables related to this assessment are defined with subscript C.

For each test, cutaneous blood flow was indexed as red blood cell flux (RBF) in perfusion units (PU) and as cutaneous vascular conductance (CVC) when RBF was controlled by mean arterial blood pressure. Results are presented as (1) the overall hyperemic response (Response), (2) the area under the curve (Area), (3) the relative change in flux expressed as a percentage of maximal dilation (%max) and (4) the time-to-peak (TTP) which represents the time from the start of the stimuli to the maximal hyperemic response. Skin resistance values were calculated from the recorded voltages using Ohm’s Law at each of the iontophoresis scans [30].

Macrovascular function

Brachial artery macrovascular function was evaluated in all the participants using the flow-mediated dilation (FMD) test. A detailed explanation of the technique has been described previously [31]. Briefly, using a 12-MHz linear transducer, simultaneous B-mode and blood velocity profiles of the brachial artery were evaluated through ultrasound imaging (Logiq 9 XD Clear, G.E. Medical Systems, Milwaukee, WI). After an initial baseline, a forearm occlusion cuff (D.E. Hokanson, Bellevue, WA) placed immediately distal to the medial epicondyle, was rapidly inflated to 250 mmHg for 5 min (E-20 rapid cuff inflator, D.E. Hokanson,) to induce arterial occlusion. Then, the pressure of the cuff was released inducing reactive hyperemia of the brachial artery [31]. Automated offline analysis of brachial artery vasodilation was completed (FMD Studio, Quippu, Italy). Peak diameter was determined by the highest five-second average following cuff release. FMD is expressed as the percent increase in peak diameter from baseline diameter. The cumulative shear rate (area under the curve, AUC) was determined every 4 s for the first 20 s, and every 5 s thereafter for the remainder 2-min data collection period using the trapezoidal rule. FMD was normalized by shear rate and presented as FMD/shear [32]. Low flow-mediated constriction (L-FMC) was calculated to evaluate resting arterial tone as the percent decrease in diameter in the last 30 s prior cuff release and compared with baseline diameter [33]. A composite endpoint (c-FMD) was also calculated as the sum of the absolute values of FMD and L-FMC [33].

Statistical analysis

The data were analyzed using SPSS version 29 (SPSS Inc., Chicago, IL) and expressed as mean ± standard error of mean (SEM) unless otherwise noted. An initial power calculation was performed based on the anticipated effect size estimated for the primary outcome (n = 15, power > 0.80). The initial proposed sample size yielded a power > 0.88 in the primary outcome for the present study (microvascular function). A power analysis and sample size calculation were performed before initiating the study, considering that under most circumstances, an α = 0.05 and a statistical power ≥ 0.80 is well accepted.

For all statistical analyses, significance was set at p < 0.05. The Shapiro–Wilk test was used to analyze the normality of the measurement distribution. When normality was met, independent group t tests were performed to identify group differences between users of e-cigarettes and non-users. If normality was not met, Mann–Whitney U tests were completed. Results are illustrated with box-and-whisker plots with minimum and maximum values. Effect size calculations using Cohen’s d were reported for primary outcomes to represent small Cohen’s d = 0.2), medium Cohen’s d = 0.5), and large Cohen’s d = 0.8) effect sizes [34, 35]. Relationships between vascular function and e-cigarette usage including frequency, length of usage, and nicotine content were evaluated using Pearson’s correlation coefficients (r). To further compare the effects of e-cigarette usage on vascular health, we divided e-cigarette users based on the median e-cigarette use duration (3 years) into those that have used e-cigarettes for longer than 3 years (> 3 year: n = 10) and those that have used these products for shorter than 3 years (≤ 3 year: n = 11).

Results

Participant characteristics

Demographic characteristics and clinical laboratory values for users of e-cigarettes and non-users are presented in Table 1. No differences in subject demographics and anthropometrics were observed between participants from both groups. Similarly, no differences were identified in the clinical laboratory values between the groups. As expected, significant (p ≤ 0.009) differences between the groups were identified in both nicotine and cotinine concentrations. Participants biological sex was considered during data analysis and no statistical differences were present between male and female participants.

Table 1 Participant characteristics and laboratory values of young users of e-cigarette and non-users

Microvascular function

Data for users of e-cigarettes (ECU) and non-users (NU) for red blood flux (RBF) and cutaneous vascular conductance (CVC) is presented in Table 2. Baseline flux and conductance were similar (p ≥ 0.098) between groups for all completed reactivity tests. Participants from both groups also showed similar Brownian movement of macromolecules in the cutaneous interstitial space (B0, ECU: 14 ± 2 PU vs. NU: 18 ± 21 PU, p = 0.107). In addition, no differences (p = 0.673) in skin resistance were identified between participants from both groups (ECU: 2.9 ± 0.2 Ω vs. NU: 2.7 ± 0.2 Ω).

Table 2 Microvascular function in young users of e-cigarettes and non-users

Local thermal hyperemia


The overall microvascular response to local thermal hyperemia was different between the users of e-cigarettes and non-users. During the initial peak in response to the thermal provocation, the ECU group exhibited a higher CVC response than the non-users (RBF, ECU: 159 ± 8 PU vs. NU: 148 ± 9 PU, p = 0.373; CVC, ECU: 1.9 ± 0.1 PU/mmHg vs. NU: 1.4 ± 0.1 PU/mmHg, p = 0.013). During the longer phase of the thermal challenge, the ECU group achieved a significantly lower maximal response than the NU for both RBF (ECU: 190 ± 8 PU vs. NU: 222 ± 7 PU, p = 0.004) and CVC (ECU: 2.3 ± 0.1 PU/mmHg vs. NU: 2.6 ± 0.1 PU/mmHg, p = 0.023, Fig. 1A). Similarly, a significantly (p = 0.022) lower response was observed when considering the area under the curve in response to the thermal challenge. In addition, the overall plateau response to the thermal challenge was significantly lower in the ECU group than in the NU (RBF: p = 0.010, Cohen’s d = 0.71; CVC, p = 0.029, Cohen’s d = 0.62, Fig. 1B).

Fig. 1
figure 1

Microvascular function in regular users of E-cigarettes (ECU) and Non-users (NU). Individual data illustrated as Box-and-Whisker plots with minimum and maximum values for A overall cutaneous vascular conductance response (CVCmax), B response to local thermal hyperemia (CVCLTH), and C response to post occlusive reactive hyperemia (CVCPORH). Group differences were determined by independent group t tests and denoted by * when p < 0.05 in users of E-Cigarettes (ECU) vs. Non-Users (NU). CVC: Cutaneous Vascular Conductance; PU: perfusion units

Post-occlusive reactive hyperemia


For the post-occlusive reactive hyperemia test, the users of e-cigarettes showed a significantly lower overall hyperemic response compared to the non-users (RBF: p = 0.003, Cohen’s d = 1.07; CVC: p = 0.016, Cohen’s d = 0.94, Fig. 1C). In addition, the maximal hyperemic response was also significantly lower in the ECU when compared to the NU group for RBF (ECU: 134 ± 8 PU vs. NU: 161 ± 6 PU, p = 0.008) and CVC (ECU: 1.6 ± 0.1 PU/mmHg vs. NU: 1.9 ± 0.1 PU/mmHg, p = 0.003). Even when considering the area under the curve in response to this test, users of e-cigarettes showed a significantly (p = 0.023) lower response than the non-users. Overall, the response to the post-occlusive reactive hyperemia test was proportionally lower in the users of e-cigarettes than in the non-users when compared to the maximal response (ECU: 57 ± 3% maximal dilation vs. NU: 69 ± 4% maximal dilation, p = 0.044).

Endothelial-dependent dilation


During the endothelium-dependent dilation test, both groups showed similar (p ≥ 0.064) responses to the delivery of acetylcholine at a lower charge (0.2–2.3 mC). However, the ECU group showed a significantly (p ≤ 0.043) reduced response rate at charges equal to or greater than 2.5 mC when compared to the NU group (Fig. 2A). Specifically, the response to the iontophoresis of acetylcholine at the highest cumulative charge (4.5 mC) was significantly lower in the e-cigarette group than in the non-users for both RBF (ECU: 72 ± 5 PU vs. NU: 98 ± 9 PU, p = 0.012, Cohen’s d = 1.15) and CVC (ECU: 0.8 ± 0.1 PU/mmHg vs. NU: 1.1 ± 0.1 PU/mmHg, p = 0.034, Cohen’s d = 1.01). In addition, the response to this reactivity test was proportionally lower in the users of e-cigarettes than in the no users when compared to the maximal response (ECU: 32 ± 3% maximal dilation vs. NU: 41 ± 3% maximal dilation, p = 0.034; Fig. 2B).

Fig. 2
figure 2

Endothelial-Dependent (EDD) and Endothelial-Independent (EID) dilation in regular users of E-cigarettes (ECU) and Non-users (NU). Endothelial Dependent (EDD) and Endothelial Independent (EID) dilation in users of E-cigarettes (ECU) and Non-Users (NU). Individual data is illustrated as Box-and-Whisker plots with minimum and maximum values as well as dose response based on an incremental current. A Dose response to acetylcholine; B Maximal endothelial-dependent dilation; C Dose response to sodium nitroprusside; D Maximal endothelial-independent dilation. Differences were determined by independent group t tests and denoted by * when p < 0.05 in users of E-Cigarettes vs. Non-Users. CVC cutaneous vascular conductance, PU perfusion units

Endothelial-independent dilation


During iontophoresis with SNP, no differences (p ≥ 0.092) were observed in the overall or maximal response between both groups at any charge (Fig. 2C). The response observed at 4.5 mC was similar for both groups both at RBF (ECU: 101 ± 10 PU vs. NU: 95 ± 9 PU, p = 0.622, Cohen’s d = 1.01) and CVC (ECU: 1.1 ± 0.1 PU/mmHg vs. NU: 1.1 ± 0.1 PU/mmHg, p = 0.773, Cohen’s d = 0.89). However, when considering the maximal dilatory capacity, the ECU group showed an overall higher proportional response to SNP than the NU group (ECU: 47 ± 4% maximal dilation vs. NU: 35 ± 4% maximal dilation, p = 0.036, Fig. 2D).

Control site


Non-specific vasodilation was monitored in a control site. No differences (p ≥ 0.114) were identified between either group at any point during the thirty-minute monitoring period. The non-specific response observed was similar between both groups when considering maximal response (ECU: 16 ± 2% maximal dilation vs. NU: 16 ± 2% maximal dilation, p = 0.781).

Macrovascular function

Table 3 presents vascular function in the brachial artery in users of e-cigarettes and non-users. The baseline diameter was similar (p = 0.336) between groups. The FMD response was similar (p = 0.086; Cohen’s d = 0.70) between both groups. No differences (p = 0.091; Cohen’s d = 0.96) in FMD normalized for shear rate were identified. In addition, the cumulative response when controlling for low flow-mediated constriction was similar (p = 0.068) in both groups.

Table 3 Macrovascular function in young users of e-cigarettes and non-users

Relationship between E-cigarette usage and vascular health

A secondary analysis was completed to evaluate the potential relationship between e-cigarette usage and vascular health assessments. Table 4 and Fig. 3 summarize micro and macrovascular results based on length of e-cigarette usage. Significant negative associations have been identified between years of e-cigarette usage and the microvascular hyperemic response (r = −0.421; p = 0.001). Indeed, the PORH response was significantly (p ≤ 0.044) lower in those individuals that used e-cigarettes for longer than three years when compared to shorter length of usage (> 3 year: 51 ± 5%max vs. ≤ 3 year: 64 ± 3%max; p = 0.039, Fig. 3A). Those that used e-cigarettes for longer than 3 years also exhibited a significantly (p ≤ 0.044) lower maximal hyperemic response both in RBF (> 3 year: 56 ± 3 PU vs. ≤3 year: 68 ± 4 PU, p = 0.044) and CVC (> 3 year: 0.70 ± 0.03 PU/mmHg vs. ≤ 3 year: 0.80 ± 0.04 PU, p = 0.036). To note, differences were independent of nicotine usage, and only moderate associations between cotinine concentrations and endothelial-independent response (r = 0.326; p = 0.031) have been observed. On the other hand, no relationships have been observed between length of usage or frequency of usage and maximal dilation, endothelial-dependent and endothelial-independent mechanisms. We also evaluated the response of larger vessels and identified that macrovascular health was negatively associated with cotinine levels (r = −0.490; p = 0.002), frequency of usage (r = −0.537; p = 0.015), and length of usage (r = −0.309; p = 0.049). Indeed, those individuals that used e-cigarettes for longer than 3 years present a significantly lower macrovascular response than those users for a shorter time (> 3 year: 6.9 ± 0.9% vs. ≤ 3 year: 10.1 ± 1.0%, p = 0.002, Fig. 3B). To note, no differences (p ≥ 0.236) in demographics, or clinical laboratory values were identified between individuals that used e-cigarettes for longer or shorter than 3 years and both nicotine and cotinine concentrations were similar (p ≥ 0.312) between both groups.

Table 4 Micro- and macro-vascular function in young users of e-cigarettes based on length of usage
Fig. 3
figure 3

Micro (A) and Macro (B) Vascular Function in Young Users of E-Cigarettes Based on Length of Usage. Differences in A microvascular function assessed through post-occlusive reactive hyperemia and B macrovascular function assessed through flow-mediated dilation in users of e-cigarettes for shorter than three years (≤ 3 year) and for longer than three years (> 3 year). Differences were determined by independent group t tests and denoted by * when p < 0.05 in > 3 year vs. ≤ 3 year of usage

Discussion

Impaired vascular health is a predictive marker of future cardiovascular dysfunction. Early evidence supports that the use of e-cigarettes may damage the vasculature and increase the risk of CVD development. The present investigation has expanded prevailing results and identified the presence of premature vascular dysfunction in young and apparently healthy regular users of e-cigarettes, specifically within the microvasculature. An interesting finding is that vascular damage in smaller blood vessels preceded damage in larger blood vessels in those that have been regularly using e-cigarettes for longer than three years. The findings of this investigation also identified that different molecular mechanisms are involved in the diminished vascular response observed in users of e-cigarettes including both endothelial-dependent and independent mechanism. Thus, the present study provides novel information on the link between e-cigarette usage and premature vascular damage and expands current knowledge related to a use timeline.

E-cigarette usage and vascular health

Currently, e-cigarettes are primarily used by young individuals who have never smoked combustible tobacco but frequently use these newer and more attractive products [36]. With the rapid increase in usage, there are rising concerns regarding the impact of the consumption of these products on users’ health. Recent studies have provided information related to the effects of these products on the health of adult users supporting that a single exposure to e-cigarettes caused a reduction in either micro [37, 38] or macro [8, 10, 11, 39] vascular function. Our results expand previous findings and identify that young regular users of e-cigarettes exhibit reduced vascular function primarily in the microvasculature, while the response of larger vessels still appears apparently preserved when length of use was not considered. It is important to note that the functionality of the small vessels plays a pivotal role in cardiovascular health and their dysfunction is considered one the earliest indicators of cardiovascular disease risk [17, 18]. Indeed, alterations in the microvasculature often precede dysfunctions observed in larger vessels [40] and are commonly considered a better predictor of long-term outcomes and adverse cardiovascular events [41,42,43]. Similar to our findings, studies completed in animal models exposed to e-cigarettes also described damage in smaller arteries prior to larger ones [44]. Thus, our data identifies, for the first time, that young users of e-cigarettes exhibit premature microvascular dysfunction when compared to demographically matched non-users that may precede damage in larger blood vessels.

Vascular function is governed by different mechanisms, with endothelial function as one of the main ones. The endothelium, a key regulator of vascular tone and blood flow, controls vasodilatory and vasoconstrictive mechanisms by synthesizing mediators such as nitric oxide, a potent vasodilator [45,46,47]. Reduced bioavailability of this vasodilator is associated with lower endothelial-dependent vasodilation and is considered a marker of poor cardiovascular health [48]. It is well established that traditional combustible tobacco usage is associated with worse endothelial function and lowered nitric oxide levels [49,50,51]. Preliminary evidence in the microvasculature [19] and other vascular beds [12] supports that e-cigarette use also leads to a reduction of this mediator [12]. Our results align with previous observations and support that regular consumers of e-cigarettes exhibit a reduction of this essential vasodilator also in the microcirculation, as evaluated through LTH. In addition, other critical mediators including prostaglandins and EDHF [52] are also involved in the endothelial-mediated response of the small vessels and may be also impaired in those that consume e-cigarettes, as suggested by our data from the PORH, LTH and iontophoresis with ACh reactivity tests. Our results support reduced endothelial-dependent microvascular function which was described in another cohort of users of e-cigarettes [19]. Recently, a study completed in a preclinical model exposed to e-cigarette vapor has also identified impaired endothelial-independent mechanisms [53]. In our study, endothelial-independent vasodilation, evaluated through iontophoresis with SNP, was similar between the groups or even higher (when percentage of maximal dilation was evaluated) in the ECU group, suggesting intact vascular smooth muscle function and even a potential overcompensation for impaired endothelial-dependent function in those young adults that are regular users of e-cigarettes. While nicotine has the ability to dimmish endothelium-independent vasodilation via interaction with ATP-sensitive K+ channels located on the vascular smooth muscle [54], studies evaluating the functionality of smooth muscle in users of cigarettes have mixed results showing reduced [55,56,57] or unchanged [58] endothelial-independent vasodilation. It is possible that length of tobacco usage may play a role in the development of general vascular dysfunction, evident first by endothelial impairments and then, by reduced vascular smooth muscle vasodilation. Analyzing the observed microvascular responses, we should also consider the possibility that e-cigarette usage hyperactivates the response initiated by sensory nerves, as evaluated via the initial response to thermal challenge, particularly due to their involvement in the initial response to the thermal challenge [59]. Prevailing data also support that acute exposure to e-cigarettes, as well as to traditional combustible tobacco, increases skin sympathetic nerve activity [60] that could lead to a poor vasodilatory response. In summary, findings from the present study expand current knowledge and demonstrate that young individuals that are regular e-cigarette users present with early alterations in different molecular mechanisms that govern microvascular function, one of the earliest markers of CVD.

E-cigarette usage length and vascular health

In the present study, we observed preserved macrovascular function in users of e-cigarettes, similar [15] and opposite [12] results have been described. Interestingly our study identified that young adults that have been using e-cigarettes for longer time also present with reduced functionality of larger vessels when compared to more recent users. Particularly, we have observed that flow-induced vasodilation in the micro- and macrovasculature, as evaluated by post-occlusive reactive hyperemia and flow-mediated dilation respectively, was reduced in those who used e-cigarette products for a longer time, while other vasodilatory mechanisms were similar between the subgroups. It is possible that over time, impairment in the microcirculation can increase vascular resistance to flow, resulting in greater retrograde and oscillatory shear in conduit arteries [61], potentially triggering an increase in oxidative stress and associated reduction in the synthesis of vasodilatory mediators [62, 63]. It is also possible that the endothelial glycocalyx, an essential mechanotransductor of shear stress that initiates intracellular signaling to promote vasodilation, will be deteriorated by the prolonged use of e-cigarettes, as previously observed in cigarette smoking [64]. In fact, recent studies have shown that endothelial glycocalyx integrity can be improved after three months of smoking cessation [65] while no changes have been observed in traditional tobacco users that switch to e-cigarettes [66]. Thus, it is possible that prolonged use of e-cigarette damages the endothelial glycocalyx resulting in decreased flow-induced vasodilation in both the micro and macro circulation. Independent of the mechanisms, the present results propose a link between length of usage and vascular damage denoting that the observed deleterious effects are not just associated with nicotine usage, as others have also identified [44, 67, 68]. Indeed, several preclinical studies reported impaired endothelial function following exposure to nicotine-free aerosol [4, 69, 70]. To note, thermal degradation of common e-liquid solvents (propylene glycol or vegetable glycerin) and the subsequent formation of different aldehydes [71, 72] have also been linked to vascular impairments [68]. In addition, early observations have also identified that certain flavor additives (i.e. cinnamon, menthol) may increase oxidative stress [73, 74] and diminish the synthesis of vasodilators in endothelial cells [75].

Study limitations

Despite the novel findings of the present study, there are also several limitations that should be considered. The study was purposely conducted in young, apparently healthy adults to eliminate the potential negative effects of aging on the vasculature. Physical activity levels, dietary intake, current and previous alcohol and drug use, or sleep patterns were similar between users and non-users. In addition, similar number of participants from both groups self-reported having consumed cannabis ever in the lifetime. However, we cannot conclude that some of these lifestyle choices or other factors not measured could influence the vascular response observed. Another limitation is related to the evaluation of microvascular function using reactivity tests. Despite providing very early insights into cardiovascular health, the technical complexity of the assessments limits the possibility to easily translated this testing into clinical settings, minimizing the ability of identifying early damage in larger and/or other populations. Another important limitation to consider is the rapidly changing market related to e-cigarettes. Indeed, from 2020 to 2022, the total number of e-cigarettes brands on the US market increased from 184 to 269 [76], providing a large variety of flavors and device types, estimated to offer 20,000 different types of e-liquids [77]. Thus, we should consider that the diversity of e-cigarette products might result in unique effects on users’ vascular health that may differ from the present findings.

Conclusion

In conclusion, results from the present study demonstrate that young and apparently healthy adults that regularly use e-cigarettes exhibit reduced vascular function that initially impacts the microcirculation. Our findings identified that those who have been users of e-cigarettes for a longer time also exhibit reduced functionality of larger blood vessels, independent of nicotine content, denoting the appearance of systemic vascular damage. We have also identified different molecular mechanisms that govern vascular health as impaired in regular users of e-cigarettes representing the multifaceted nature of the observed damage. Results from the present study add to the growing body of literature emphasizing that the usage of e-cigarettes is not a harmless action and could contribute to the onset of premature cardiovascular diseases.