Abstract
Six kinematic parameters are needed to fully describe three-dimensional (3D) bone motion at a joint. At the knee, the relative movements of the femur and tibia are often represented by a 1-degree-of-freedom (1-DOF) model with a single flexion–extension axis or a 2-DOF model comprising a flexion–extension axis and an internal–external rotation axis. The primary aim of this study was to determine the accuracy with which 1-DOF and 2-DOF models predict the 3D movements of the femur, tibia and patella during daily activities. Each model was created by fitting polynomial functions to 3D tibiofemoral (TF) and patellofemoral (PF) kinematic data recorded from 10 healthy individuals performing 6 functional activities. Model cross-validation analyses showed that the 2-DOF model predicted 3D knee kinematics more accurately than the 1-DOF model. At the TF joint, mean root-mean-square (RMS) errors across all activities and all participants were 3.4°|mm (deg or mm) for the 1-DOF model and 2.4°|mm for the 2-DOF model. At the PF joint, mean RMS errors were 4.0°|mm and 3.9°|mm for the 1-DOF and 2-DOF models, respectively. These results indicate that a 2-DOF model with two rotations as inputs may be used with confidence to predict the full 3D motion of the knee-joint complex.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Six parameters are needed to fully describe the relative positions of the bones which meet at a joint. At the knee, the three-dimensional (3D) movements of the tibia relative to the femur are usually described by the tibiofemoral flexion angle, which represents the primary motion of the knee, together with 5 secondary motions comprising external rotation, abduction, anterior translation, lateral shift, and joint distraction. Similarly, the 3D movements of the patella relative to the femur are described using another set of 3 rotations and 3 translations. Thus, at most 12 kinematic parameters are needed to describe all relative movements of the femur, tibia and patella at the knee. However, some or all of these parameters may be related (or coupled) to each other due to the constraints imposed by the knee ligaments, capsular structures, and articular contact at the joint.2,6,19,21
Experiments on intact cadaver knees suggest that the relative movements of the femur and tibia may be described using two simultaneous rotations occurring about fixed axes.11 Tibiofemoral flexion–extension occurs about a mediolateral axis fixed in the femur and passing close to the centers of the femoral condyles, whereas internal–external rotation of the tibia occurs about a longitudinal axis fixed in the tibia and passing through the medial tibial plateau. These two rotations, tibiofemoral flexion and external tibial rotation, which define a two-degree-of-freedom (2-DOF) kinematic system, were found to adequately describe the 3D movements of the femur and tibia during weightbearing activity simulated in vitro.3 Wilson et al.25,26 challenged this proposition by showing that all five secondary motions of the tibia traced the same paths relative to the femur when cadaver knees were moved passively in unloaded flexion and extension, implying that the tibiofemoral joint has 1-DOF. Sancisi and Parenti-Castelli21 showed further that the 3D movements of the femur, tibia and patella may be reproduced during passive (unloaded) flexion using a 1-DOF spatial kinematic mechanism with the tibiofemoral flexion angle specified as an input.
More recent in vivo studies have found that some, but not all, of the secondary motions of the tibia are coupled to the tibiofemoral flexion angle during seated knee extension5 and level walking.12,13 In our previous work, mobile biplane X-ray imaging was used to measure all 12 tibiofemoral (TF) and patellofemoral (PF) kinematic parameters for a wide range of daily activities.23 We found that 7 of the 11 secondary motions of the bones—3 translations at the TF joint, 3 translations at the PF joint, and patellar flexion—were coupled to the TF flexion angle. Importantly, external tibial rotation was only weakly related to the TF flexion angle. These results support the view that a kinematic model with more than 1 DOF is needed to accurately describe 3D bone motion at the knee.3,11
The main aim of the present study was to determine the accuracy with which 1-DOF and 2-DOF knee models predict the full 3D movements of the femur, tibia and patella during dynamic activity. A 1-DOF model with the TF flexion angle as the only input and a 2-DOF model with TF flexion and external tibial rotation as inputs were constructed by fitting polynomial functions to all 12 TF and PF kinematic parameters measured for 6 functional activities: level walking, downhill walking, stair ascent, stair descent, and open-chain knee flexion and extension. Multivariate regression was performed to investigate how well each model described the kinematic behavior of the knee-joint complex across all 6 activities. A ‘leave-one-out’ cross-validation analysis was then conducted to evaluate the accuracy with which the 1-DOF and 2-DOF models predicted 3D TF and PF joint kinematics across all 6 activities. We hypothesized that a 2-DOF kinematic model with TF flexion and external tibial rotation as inputs would predict all remaining secondary motions of the tibia and patella more accurately than a 1-DOF kinematic model with only the TF flexion angle specified. A kinematic model that accurately predicts the 3D movements of the femur, tibia and patella may improve existing musculoskeletal models that use skin-marker measurements obtained from video motion capture to estimate muscle and joint loading at the knee.4
Materials and Methods
Participants
Ten healthy individuals (6 males and 4 females; age 29.8 ± 6.1 years; height 168.0 ± 9.9 cm; weight 68.3 ± 9.0 kg) with no knee pain and no history of lower-limb surgery gave informed consent to participate in this study. Ethics approval for the experimental procedures was obtained from the Human Research Ethics Committee at the University of Melbourne.
Experimental data
6-DOF TF and 6-DOF PF joint kinematics for a range of activities of daily living were reported previously by Thomeer et al.,23 where details relating to data collection and processing are also given. Each participant performed open-chain knee flexion–extension (125.9 ± 21.0 deg/s), level walking (1.31 ± 0.14 m/s), downhill walking (0.84 ± 0.09 m/s), stair ascent (0.63 ± 0.09 m/s), and stair descent (0.62 ± 0.05 m/s). Open-chain knee flexion–extension was performed with the participant standing on the left leg and flexing the right knee to lift the right foot off the ground. Knee flexion and knee extension were treated as two separate activities even though data were collected for a single continuous cycle of flexion–extension. Downhill walking was performed on a wooden surface sloped at 10 degrees relative to a level laboratory floor, while stair ascent and stair descent were performed on a wooden staircase comprised of 17 cm high steps (see Fig. 1 in Thomeer et al.23 for details). Biplane X-ray images (1024 × 1024 pixels, 200 frames/s, 1/200 s exposure time) of the right knee were acquired using a Mobile Biplane X-ray (MoBiX) imaging system.10 The biplane X-ray images were then imported to custom software in MATLAB (MathWorks Inc., Natick, MA) to perform pose-estimation of the femur, tibia and patella and calculate TF and PF joint kinematics. Geometric models of each bone required for pose estimation were created from CT scans (0.35 × 0.35 × 0.50 mm) taken of the right knee. Coordinate systems were assigned to the femur, tibia and patella to describe joint kinematics in an anatomically meaningful way9 (Fig. 1). Maximum root-mean-square (RMS) errors associated with 3D kinematic measurements of the intact knee were reported previously to be 0.78 mm and 0.77° for translations and rotations of the TF joint10 and 0.37 mm and 1.46° for translations and rotations of the PF joint.8
TF and PF joint kinematics measured simultaneously for 60 motion trials (1 trial per activity and 6 activities for each of the 10 participants) were analyzed in the present study. Kinematic data for each trial were filtered using a fourth-order, low-pass, Butterworth filter with a cut-off frequency of 10 Hz and then resampled to 201 time points to create 201 observations. Each observation contained 12 kinematic parameters: lateral shift, anterior drawer, joint distraction, flexion, abduction, and external rotation at the TF joint; and lateral shift, anterior translation, superior translation, flexion, lateral rotation, and lateral tilt at the PF joint (Fig. 1). TF and PF translations were normalized by the ratio of femoral bicondylar width measured for each participant to the mean femoral bicondylar width calculated across all 10 participants (81.7 mm)
Multivariate Regression
Multivariate regression was performed to determine how accurately 1-DOF and 2-DOF models describe the kinematic behavior of the knee-joint complex across all 6 activities. Second-order polynomial equations were used to fit the complete set of 3D kinematic data (i.e., 12 kinematic parameters for the TF and PF joints combined) obtained from biplane X-ray imaging (see Section S2 of the Supplementary Material, which provides a justification for the use of second-order polynomials). Each polynomial equation described the relationship between the input TF kinematic parameters (e.g., TF flexion angle) and one of the remaining kinematic parameters defining either TF or PF joint motion (e.g., patellar flexion). A 1-DOF model consisted of 11 second-order polynomial functions with the TF flexion angle defined as the input variable. Each polynomial described one of the 11 secondary kinematic parameters (\(y\)) as a function of the TF flexion angle and took the form:
where \(f\) is the TF flexion angle, and \(c_{0}\) and \({\text{c}}_{ij}\) are constant coefficients. Similarly, a 2-DOF model consisted of 10 second-order polynomials, with each polynomial defined as a function of two input variables: TF flexion and external tibial rotation. Here, each polynomial described one of the 10 remaining kinematic parameters (\(y\)) and took the form:
where \(f\) is the TF flexion angle, \(e\) is external tibial rotation, and \(c_{0}\) and \({\text{c}}_{ij}\) are constant coefficients. The coefficients in each model were found using a least-squares method. Each polynomial in the 1-DOF and 2-DOF models was created by fitting 12,060 observations obtained by pooling data from all 60 motion trials (201 time points per trial and 6 trials for each of the 10 participants). For individual participants, 1-DOF and 2-DOF models were also created by fitting 1206 observations obtained by pooling data from all 6 activities for each participant (201 time points per trial and 6 trials for each participant).
To determine how accurately each model described the kinematic behavior of the knee-joint complex, a fitting residual for each polynomial was calculated for the TF joint and PF joint separately for the 1-DOF and 2-DOF models. RMS residuals for the TF joint (\({\text{RMSR}}_{{{\text{TFJ}}}}\)) were computed as follows:
where \(y_{ij}\) and \(y_{ij}^{^{\prime}}\) are, respectively, the fitted and measured values of each output TF kinematic parameter (indexed by \(i\)) for each observation (indexed by \(j\)); \(p\) is the number of observations; and \(n\) is the number of input TF kinematic parameters (i.e., the number of DOFs of the model, \(n = 1 \;{\text{or}} \;2\)). Similarly, RMS residuals for the PF joint (\({\text{RMSR}}_{{{\text{PFJ}}}}\)) were obtained as follows:
where \(y_{ij}\) and \(y_{ij}^{^{\prime}}\) are, respectively, the fitted and measured values of each PF kinematic parameter (indexed by \(i\)) for each observation (indexed by \(j\)); and \(p\) is the number of observations. Rotations of 1° and translations of 1 mm were weighted equally at both the TF and PF joints, and the notation 1°|mm was used to indicate a residual value of 1° or 1 mm. The model that more accurately described the kinematic behavior of the knee-joint complex was the one associated with lower residuals at the TF and PF joints.
Model Cross-Validation
A ‘leave-one-out’ cross-validation1,18 was conducted to evaluate the accuracy with which a 1-DOF model and a 2-DOF model predicted the 3D movements of the femur, tibia and patella across all activities. Second-order polynomials were again used to create 1-DOF and 2-DOF models by fitting the kinematic data for 54 trials obtained for 9 of the 10 participants (1 trial per activity and 6 activities for each of the 9 participants). Each model was then used to predict 3D TF and PF kinematics for the one remaining (left-out) participant. This procedure was performed 10 times by ‘leaving out’ a different participant’s data on each occasion. Model accuracy was quantified by calculating the errors between the predicted and measured values for each TF and PF output kinematic parameter.
Results
Multivariate Regression
When data from all participants were pooled, RMS residuals for the 1-DOF model were 3.3°|mm at the TF joint and 3.8°|mm at the PF joint compared to 2.2°|mm at the TF joint and 3.5°|mm at the PF joint for the 2-DOF model (Fig. 2, left panel). Thus, increasing the number of DOFs from 1 to 2 reduced the residual by 1.1°|mm (33%) at the TF joint and by 0.3°|mm (8%) at the PF joint. A similar trend was observed when data from all 6 activities were pooled for each participant (Fig. 2, right panel). In this instance, increasing the number of DOFs from 1 to 2 reduced the residual by 0.9°|mm (45%) at the TF joint and by 0.2°|mm (9%) at the PF joint. Polynomial equations defining the 1-DOF and 2-DOF knee models are presented in Table 1.
Model Cross-Validation
The 2-DOF model predicted 3D TF and PF kinematics more accurately than the 1-DOF model (Table 2, Figs. 3 and 4). At the TF joint, the mean RMS error for the 1-DOF model across all activities and all participants was 3.4°|mm compared to 2.4°|mm for the 2-DOF model (Table 2, Panel A). External rotation was associated with the largest RMS error for each participant when a 1-DOF model was used to predict 3D knee motion (range: 3.0°|mm to 10.0°|mm; mean: 5.8°|mm). Mean RMS errors for the 4 remaining TF kinematic parameters (i.e., abduction plus all three translations) were similar for the 1-DOF and 2-DOF models.
At the PF joint, mean RMS errors across all activities and all participants were 4.0°|mm and 3.9°|mm for the 1-DOF and 2-DOF models, respectively (Table 2, Panel B). Mean RMS errors for the 1-DOF and 2-DOF models were similar for each of the 6 PF kinematic parameters, with the largest error associated with lateral patellar rotation. Mean RMS errors for lateral patellar rotation were 5.5°|mm (range 2.7°|mm to 12.2°|mm) for the 1-DOF model and 5.9°|mm (range 2.8°|mm to 12.0°|mm) for the 2-DOF model.
RMS errors in the mean values of all kinematic parameters other than TF flexion and external tibial rotation were comparable for the 1-DOF and 2-DOF models for each of the 6 activities (compare the red and blue values in the last column of Figs. 3, 4). Differences in the RMS errors calculated for these 10 kinematic parameters ranged from 0.1 to 0.6°|mm (see rows labelled “AA” in the “RMSE” column in Figs. 3, 4).
Discussion
The primary aim of this study was to determine the accuracy with which 1-DOF and 2-DOF kinematic models of the knee predict the 3D movements of the femur, tibia and patella for a wide range of daily activities. A multivariate regression analysis performed across 6 functional activities showed that a 2-DOF model with TF flexion and external tibial rotation as inputs describes the kinematic behavior of the knee-joint complex more accurately than a 1-DOF model with only TF flexion as the input (Fig. 2). Model cross-validation showed further that the 2-DOF model predicts 3D TF and PF joint kinematics more accurately than the 1-DOF model across all activities (Table 2, Figs. 3, 4), thus supporting our hypothesis.
The 1-DOF model was created by plotting TF and PF kinematic parameters against the TF flexion angle and using second-order polynomial equations to describe the relationships between each output kinematic parameter and the input TF flexion angle. A similar process was followed for the 2-DOF model, where each output kinematic parameter was plotted against two inputs: TF flexion angle and external tibial rotation. We selected these variables as input kinematic parameters for three reasons. First, the knee is often represented as a 1-DOF system where a single axis of rotation is used to reproduce the relative movements of the femur, tibia and patella.3,11,12,13,14,16,17,22,24,26 Second, TF flexion and external tibial rotation were used to define a 2-DOF model described previously by Hollister et al.11 and Churchill et al.3 Third, TF flexion and external tibial rotation represent the largest relative motions between the femur and tibia23 and are commonly measured using video motion capture and skin-mounted markers.20
There are many other combinations of TF kinematic parameters that could have been selected as inputs to a knee model. We used multivariate regression to investigate how well each of these different models describes the kinematic behavior of the knee-joint complex across all participants and all activities (Supplementary Material, Section S1). Specifically, second-order polynomial equations were used to fit the TF and PF kinematic data for 2-DOF, 3-DOF, 4-DOF and 5-DOF models with different combinations of TF kinematic parameters chosen as inputs. TF flexion was always included as one of these input kinematic parameters because it represents the primary motion of the knee joint. Thus, a 2-DOF model was represented by the TF flexion angle and one of the remaining five TF kinematic parameters (e.g., anterior tibial translation). Similarly, a 3-DOF model was represented by the TF flexion angle and two of the remaining five TF kinematic parameters (e.g., external tibial rotation and tibial abduction). This analysis yielded three important results. First, we found that from all possible combinations of input kinematic parameters used to define a 2-DOF model, the one with TF flexion and external tibial rotation as inputs gave the lowest residual (Fig. S1, top-left panel). Second, increasing the number of DOFs of the model beyond two brought diminishing returns as the magnitude of the residual decreased only slightly. Specifically, the residual was reduced by 0.9°|mm from 2.0 to 1.1°|mm when the number of DOFs was increased from one to two (Fig. S1, first column). However, increasing the number of DOFs from two to three reduced the residual by just 0.2°|mm, and increasing the number of DOFs further still to five reduced the residual by another 0.5°|mm. Third, increasing the number of DOFs of the model by using a larger number of TF kinematic parameters as inputs had a relatively small effect on the residuals calculated for the PF joint (Fig. S1, second column). The residual at the PF joint for a 1-DOF model with TF flexion as the input was 2.2°|mm compared to 1.7°|mm when the number of input parameters was increased to six (i.e., a total reduction of 0.5°|mm). By comparison, the residual at the TF joint decreased by 1.5°|mm when the number of input parameters was increased from one to five (Fig. S1).
Although we found that a 5-DOF model yields a lower residual than a 1-DOF model, this result is mainly of theoretical interest and has limited practical value. In practice, tibial abduction or any of the three TF translations are not likely to be used as inputs to a knee model because these kinematic parameters cannot be measured accurately using standard motion analysis techniques, such as video motion capture with skin markers. We suggest, therefore, that a 2-DOF model with two input parameters—the TF flexion angle measured about a mediolateral axis fixed in the femur (XF in Fig. 1) and external tibial rotation measured about a longitudinal axis fixed in the tibia (ZT in Fig. 1)—is the most suitable structure for describing the kinematic behavior of the knee-joint complex.
Each knee model was created by fitting second-order polynomials to 3D TF and PF kinematic data obtained from mobile biplane X-ray imaging. We also examined the effect of using polynomials of lower and higher order than two to fit the kinematic measurements (Supplementary Material, Section S2). The order of the polynomials had a relatively small effect on the residuals calculated at the TF and PF joints in each model (Fig. S2). For example, fitting the kinematic data using fourth-order rather than second-order polynomial functions reduced the residuals by less than 0.1°|mm at the TF joint and ~ 0.1°|mm at the PF joint. Thus, second-order polynomials were used in the current analysis as a compromise between the complexity of a model and its ability to accurately fit the 3D knee kinematic data.
One of the main findings of our study was that the 1-DOF model did not accurately predict external tibial rotation. The mean RMSE for external tibial rotation was 5.8°, whereas the errors associated with the four remaining kinematic parameters at the TF joint and all six kinematic parameters at the PF joint were similar for the 1-DOF and 2-DOF models (Table 2). We therefore recommend the 2-DOF for predicting 3D knee kinematics, even though the 1-DOF model with only one input kinematic parameter (TF flexion) may be more practical to implement. The reason is that measurements of internal–external tibial rotation obtained from standard gait analysis experiments are likely to be more accurate than the values of external tibial rotation predicted by the 1-DOF model described here. Using video motion capture with skin markers to measure 6-DOF knee kinematics across a wide range of activities, Richard et al.20 reported a mean RMS error for internal–external rotation of 2.7° (range 2.1°–3.8°), which is lower than the error in external tibial rotation predicted by the 1-DOF model.
Two previous studies created 1-DOF knee models by fitting polynomial functions to the kinematic parameters describing the relative motion of the femur and tibia obtained from biplane X-ray imaging.12,13 We compared the performance of each of these models to that of the 1-DOF and 2-DOF models described in the present study (Table 1). Each model was used to predict all remaining secondary motions at the TF joint for one cycle of level walking, and model accuracy was assessed by comparing the predictions against in vivo 3D knee kinematic data measured from biplane X-ray imaging.9 The secondary motions of the tibia relative to the femur predicted by our 1-DOF and 2-DOF models were consistently within 1 standard deviation of the mean experimental data whereas the results obtained from the models reported in the literature were noticeably different (Fig. 5). The 1-DOF models reported by Hume et al.12 and Koo and Koo13 yielded predictions where the tibia was more abducted and medially shifted throughout the gait cycle as well as more internally rotated during swing. In addition, there were relatively small differences between the trajectories predicted by our 1-DOF and 2-DOF models. Although external tibial rotation predicted by the 1-DOF model remained within 1 standard deviation of the mean experimental data, the error in this kinematic parameter was ~ 5° over the entire gait cycle. This finding is consistent with the results obtained from the model cross-validation analysis and reinforces the fact that the main difference between the 1-DOF and 2-DOF models is the inability of the 1-DOF model to accurately predict external tibial rotation.
We found that all 6 PF kinematic parameters could be predicted to an accuracy of 4.0°|mm when TF flexion was the only input kinematic parameter used, and that a relatively small improvement (0.1°|mm) was obtained when a 2-DOF model was created with external tibial rotation added as an input (Table 2, Panel B). Adding external tibial rotation as an input improved the accuracies with which patellar flexion and lateral patellar tilt were predicted, but it also increased the errors in the predictions of anterior patellar translation and lateral patellar rotation. We conclude that patellar motion is more heavily influenced by the TF flexion angle than external tibial rotation. TF flexion predicted lateral patellar tilt, lateral patellar shift, and anterior patellar translation more accurately than patellar flexion, lateral patellar rotation, and superior patellar translation, which may be explained by the geometry of the PF joint. At TF flexion angles greater than ~ 20° the patella enters the femoral trochlea,15 and lateral patellar shift and tilt are then determined primarily by the shapes of the articulating surfaces of the patellar facets and trochlear groove. In contrast, patellar flexion, lateral patellar rotation, and superior patellar translation are influenced not only by the geometry of the PF joint but also by the activation of the quadriceps muscles and their lines of action.
It is important to note that the polynomial equations describing our 1-DOF and 2-DOF models (Table 1) must be used in conjunction with the joint coordinate system given in Fig. 1 because the kinematic parameters for the TF and PF joints in each model were defined in this coordinate system. For the same knee motion, values of kinematic parameters are likely to be different when a different joint coordinate system is used to define these parameters. To apply the equations in Table 1 to a knee model defined by a different joint coordinate system, a set of transformation matrices must be derived to relate the new coordinate system to the one in Fig. 1 to ensure that the correct knee motion is predicted. In Section S3 of the Supplementary Material, we derive the transformation matrices that relate our joint coordinate system to the one used in OpenSim.4 These transformation matrices allow the joint coordinate system specified in Fig. 1 to be applied in OpenSim. The equations given in Table 1 then may be used to calculate 3D TF and PF kinematics.
One limitation of the present study is that the 1-DOF and 2-DOF models were developed from knee kinematic data recorded for 6 activities of daily living performed by healthy young people. Caution is advised when using these models to predict knee kinematics for other activities (e.g., running) or another cohort of participants (e.g., healthy older people or individuals with conditions such as knee osteoarthritis). Another limitation of our results is that the RMS errors associated with the model-predicted knee kinematics are much larger than the accuracy with which the relative movements of the bones can be measured using biplane X-ray imaging. For example, the mean RMS error in predicting external tibial rotation using the 1-DOF knee model was 5.8° compared to an RMS error of 0.6° obtained from biplane X-ray imaging.10 The relatively high errors in the model predictions can be explained firstly by the observation that no two kinematic parameters at either the TF or PF joint are perfectly coupled to each other23; and secondly by the relatively high inter-participant variability in the knee kinematic data.7 In addition, the model predictions are inextricably linked to the reference frame assigned to each bone. Because the positions and orientations of the axes defining the reference frame are usually determined by bony prominences, errors in model-predicted knee kinematics ultimately depend on the accuracy with which reference frames can be assigned to an individual participant based on their anatomy. Finally, even though our 1-DOF and 2-DOF models were developed using participant-specific knee kinematic data, the only anatomical feature considered was the femoral bicondylar width. Using other anatomical features such as tibial slope, femoral condyle diameter, and patellar facet width to personalize the model may yield more accurate predictions of TF and PF joint motion for individual participants, but this approach is also likely to make implementation of the model more difficult.
In summary, we found that a 2-DOF model with TF flexion and external tibial rotation as inputs predicted 3D knee kinematics more accurately than a 1-DOF model with only TF flexion specified as an input. At the TF joint, mean RMS errors across all activities and all participants were 3.4°|mm and 2.4°|mm for the 1-DOF and 2-DOF models, respectively. At the PF joint, mean RMS errors across all activities and all participants were 4.0°|mm and 3.9°|mm for 1-DOF and 2-DOF models. These results indicate that a 2-DOF knee model with two rotations as inputs may be used with confidence to predict the full 3D motion of the knee-joint complex.
References
Arlot, S., and A. Celisse. A survey of cross-validation procedures for model selection. Stat. Surv. 4:40–79, 2010.
Blankevoort, L., R. Huiskes, and A. de Lange. The envelope of passive knee joint motion. J. Biomech. 21(9):705–720, 1988.
Churchill, D. L., S. J. Incavo, C. C. Johnson, and B. D. Beynnon. The transepicondylar axis approximates the optimal flexion axis of the knee. Clin. Orthop. Relat. Res. 356:111–118, 1998.
Delp, S. L., F. C. Anderson, A. S. Arnold, P. Loan, A. Habib, C. T. John, E. Guendelman, and D. G. Thelen. Opensim: open-source software to create and analyze dynamic simulations of movement. IEEE Trans. Biomed. Eng. 54(11):1940–1950, 2007.
Dyrby, C. O., and T. P. Andriacchi. Secondary motions of the knee during weight bearing and non-weight bearing activities. J. Orthop. Res. 22(4):794–800, 2004.
Feikes, J. D., J. J. O’Connor, and A. B. Zavatsky. A constraint-based approach to modelling the mobility of the human knee joint. J. Biomech. 36(1):125–129, 2003.
Gale, T., and W. Anderst. Asymmetry in healthy adult knee kinematics revealed through biplane radiography of the full gait cycle. J. Orthop. Res. 37(3):609–614, 2019.
Gray, H. A., S. Guan, and M. G. Pandy. Accuracy of mobile biplane x-ray imaging in measuring 6-degree-of-freedom patellofemoral kinematics during overground gait. J. Biomech. 57:152–156, 2017.
Gray, H. A., S. Guan, L. T. Thomeer, A. G. Schache, R. de Steiger, and M. G. Pandy. Three-dimensional motion of the knee-joint complex during normal walking revealed by mobile biplane x-ray imaging. J. Orthop. Res. 37(3):615–630, 2019.
Guan, S., H. A. Gray, F. Keynejad, and M. G. Pandy. Mobile biplane x-ray imaging system for measuring 3d dynamic joint motion during overground gait. IEEE Trans. Med. Imaging. 35(1):326–336, 2016.
Hollister, A. M., S. Jatana, A. K. Singh, W. W. Sullivan, and A. G. Lupichuk. The axes of rotation of the knee. Clin. Orthop. Relat. Res. 290:259–268, 1993.
Hume, D. R., V. Kefala, M. D. Harris, and K. B. Shelburne. Comparison of marker-based and stereo radiography knee kinematics in activities of daily living. Ann. Biomed. Eng. 46(11):1806–1815, 2018.
Koo Y.-J. and S. Koo. Three-dimensional kinematic coupling of the healthy knee during treadmill walking. J. Biomech. Eng. 141(8), 2019.
Lin, Y.-C., and M. G. Pandy. Three-dimensional data-tracking dynamic optimization simulations of human locomotion generated by direct collocation. J. Biomech. 59:1–8, 2017.
Loudon, J. K. Biomechanics and pathomechanics of the patellofemoral joint. Int. J. Sports Phys. Ther. 11(6):820–830, 2016.
Marra, M. A., V. Vanheule, R. Fluit, B. H. F. J. M. Koopman, J. Rasmussen, N. Verdonschot, and M. S. Andersen. A subject-specific musculoskeletal modeling framework to predict in vivo mechanics of total knee arthroplasty. J. Biomech. Eng. 137(2):020904, 2015.
Moissenet, F., L. Chèze, and R. Dumas. A 3d lower limb musculoskeletal model for simultaneous estimation of musculo-tendon, joint contact, ligament and bone forces during gait. J. Biomech. 47(1):50–58, 2014.
Moreira, L., J. Figueiredo, J. P. Vilas-Boas, and C. P. Santos. Kinematics, speed, and anthropometry-based ankle joint torque estimation: a deep learning regression approach. Machines. 9(8):154, 2021.
O’Connor, J. J., T. L. Shercliff, E. Biden, and J. W. Goodfellow. The geometry of the knee in the sagittal plane. Proc. Inst. Mech. Eng. Part H. 203(4):223–233, 1989.
Richard, V., A. Cappozzo, and R. Dumas. Comparative assessment of knee joint models used in multi-body kinematics optimisation for soft tissue artefact compensation. J. Biomech. 62:95–101, 2017.
Sancisi, N., and V. Parenti-Castelli. A new kinematic model of the passive motion of the knee inclusive of the patella. J. Mech. Robot. 3(4):041003, 2011.
Sritharan, P., Y.-C. Lin, and M. G. Pandy. Muscles that do not cross the knee contribute to the knee adduction moment and tibiofemoral compartment loading during gait. J. Orthop. Res. 30(10):1586–1595, 2012.
Thomeer, L., S. Guan, H. Gray, A. Schache, R. de Steiger, and M. Pandy. Six-degree-of-freedom tibiofemoral and patellofemoral joint motion during activities of daily living. Ann. Biomed. Eng. 49(4):1183–1198, 2021.
Viceconti, M., D. Ascani, and C. Mazzà. Pre-operative prediction of soft tissue balancing in knee arthoplasty part 1: effect of surgical parameters during level walking. J. Orthop. Res. 37(7):1537–1545, 2019.
Wilson, D. R., J. D. Feikes, and J. J. O’Connor. Ligaments and articular contact guide passive knee flexion. J. Biomech. 31(12):1127–1136, 1998.
Wilson, D. R., J. D. Feikes, A. B. Zavatsky, and J. J. O’Connor. The components of passive knee movement are coupled to flexion angle. J. Biomech. 33(4):465–473, 2000.
Acknowledgments
This work was supported in part by a Discovery Projects Grant from the Australian Research Council (DP190102365) to MGP.
Funding
Open Access funding enabled and organized by CAUL and its Member Institutions.
Author information
Authors and Affiliations
Contributions
SG, HAG, LTT, and MGP designed the study. MGP obtained funding for the research. SG, HAG, and LTT performed the data analysis. SG, HAG, LTT, and MGP interpreted the data and drafted the manuscript. All authors edited, revised, and approved the final version. MGP was the chief investigator for the study.
Corresponding author
Ethics declarations
Conflict of interest
There are no conflicts of interest to report in the preparation of this manuscript.
Additional information
Associate Editor Joel Stitzel oversaw the review of this article.
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Guan, S., Gray, H.A., Thomeer, L.T. et al. A Two-Degree-of-Freedom Knee Model Predicts Full Three-Dimensional Tibiofemoral and Patellofemoral Joint Motion During Functional Activity. Ann Biomed Eng 51, 493–505 (2023). https://doi.org/10.1007/s10439-022-03048-2
Received:
Accepted:
Published:
Issue Date: