Abstract

We present a novel method of 3-dimensional surface fitting of a droplet using ellipsoids such that the droplet is a combination of segments of two to four distinct ellipsoids. Further, this fitting method has been used to develop an analytical model estimating the volume of a droplet resting over compliant as well as non-compliant substrate. Here, we have used Glass and Poly (methyl methacrylate) (PMMA) substrates as rigid, and Polydimethylsiloxane (PDMS) free-hanging thin membranes (with thickness ranging from 20–40 µm) as compliant substrates. The analytical model considers the base length, width, height, and contact angles of the droplet captured from the experiment and estimates the droplet volume. The proposed analytical model could predict the volume correctly for droplets resting over compliant as well as non-compliant substrates with a maximum deviation of 16.6% for the volume range of 5–70 µL. Further, the predictions from the proposed analytical model are compared with the spherical cap-based model for droplets placed over compliant as well as non-compliant substrates. While the spherical cap-based model failed to accurately estimate droplet volume over a compliant substrate with an error of over 50%, the ellipsoid-based model proposed in this study could predict droplet volume accurately with a maximum error of 16.6%. Also, the proposed analytical model estimates the volume of droplets even at high contact angle hysteresis (> 50°) where the droplet has high azimuthal asymmetry. Further, the study also illustrates how Artificial Neural Networks (ANNs) can be used to forecast droplet width and contact angle hysteresis (CAH). The droplet width predicted from ANN could be used to eliminate the requirement of measuring droplet width from the top view experimental image. The volume of the droplet can thus be predicted from its side profile alone when utilized in conjunction with the theoretical model. Further, we developed an ANN model which predicts the CAH of the droplet by considering the length scales of the droplet. The developed ANN models performed a very good prediction with an R-value of \(>0.98\).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10

Similar content being viewed by others

Data availability

The data that support the findings of this study is available from the corresponding author upon request.

References

Download references

Acknowledgements

The authors would like to thank the Science and Engineering Research Board (SERB), Department of Science and Technology (DST), Government of India for providing the fund via grant no. SRG/2020/002268.

Author information

Authors and Affiliations

Authors

Contributions

SAH Conceptualization; Data curation; Data analysis; Investigation; Methodology; Validation; Visualization; Writing original draft. AR Conceptualization, Data Analysis, Methodology, Funding acquisition, Resources; Supervision, Project administration; Writing–review & editing.

Corresponding author

Correspondence to Abhishek Raj.

Ethics declarations

Conflicts of interest

The authors have no conflict of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Below is the link to the electronic supplementary material.

Supplementary file1 (DOCX 1310 KB)

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Haider, S.A., Raj, A. Liquid drops on compliant and non-compliant substrates: an ellipsoid-based fitting for approximating drop shape and volume. Microfluid Nanofluid 27, 49 (2023). https://doi.org/10.1007/s10404-023-02659-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s10404-023-02659-y

Keywords

Navigation