Programmed-temperature retention indices (PTRIs) are useful for the identification and quantification of chemicals by means of GC and GC/MS. To obtain reproducible PTRIs, we studied the influence of average linear velocity and column length under the constant average linear velocity control (CVC) using 55 pesticides and 33 fatty acid methyl esters. The PTRIs decreased with increasing average linear velocity, and the degree of decrease differs with the compounds. The PTRIs, however, were almost constant as long as the same average linear velocity was used even if the column length was changed. In addition, the correlation between the variation ratio in PTRI and the increase in average linear velocity was linear. Using the linear relationship between PTRIs and average linear velocities under CVC, highly reproducible PTRIs were obtained even if the capillary column length changes. Furthermore, the PTRIs determined by GC with FID, ECD, and FPD under atmospheric pressure were applied to GC/MS under vacuum or vice versa. From these results, it was confirmed that because CVC provides reproducible retention indices, CVC is advantageous for qualitative and quantitative analysis by GC and GC/MS.
Similar content being viewed by others
References
Mondello L, Dugo P, Basile A, Dugo G, Bartle KD (1995) J Microcolumn Sep 7:581–591
Ruther J (2000) J Chromatogr A 890:313–319
National Institute of Standards and Technology (2005) NIST/EPA/NIH Mass Spectral Library (Data version: NIST 05), NIST Standard Reference Database 1A, Gaithersburg, MD, USA
Kadokami K, Tanada K, Taneda K, Nakagawa K (2005) J Chromatogr A 1089:219–226
Kováts E (1958) Helv Chim Acta 41:1915–1932
Van Den Dool H, Kratz PD (1963) J Chromatogr 11:463–471
Blomberg LG (1987) Adv Chromatogr 26:229–276
Evans MB, Haken JK (1989) J Chromatogr 472:93–127
Hinshaw JV (1995) LC–GC 13:792–796
Kokko M (1993) J Chromatogr 630:231–249
Pell RJ, Gearhart HL (1987) J High Resolut Chromatogr 10:388–391
White CM, Hackett J, Anderson RR, Kail S, Spock PS (1992) J High Resolut Chromatogr 15:105–120
Baaliouamer A, Boudarene L, Meklati BY (1993) Chromatographia 35:67–72
Blumberg LM, Klee MS (1998) Anal Chem 70:3828–3839
Gonzalez FR, Nardillo AM (1999) J Chromatogr A 842:29–49
Knöppel H, De Bortoli M, Peil A, Vissers H (1983) J Chromatogr 279:483–492
Yin HF, Sun YL (1990) Chromatographia 29:39–43
Cramers CA, Rijks JA, Schutjes CPM (1981) Chromatographia 14:439–444
Gonzalez FR, Nardillo AM (1997) J Chromatogr A 766:147–152
COMMISSION DECISION 2002/657/EC of 12 August 2002 implementing Council Directive. 96/23/EC concerning the performance of analytical methods and the interpretation of results. Official. Journal of the European Communities L 221/8-36
Castello G (1999) J Chromatogr A 842:51–64
Nakagawa K, Kawana S, Yamaguchi S (2008) Chromatographia 67:731–740
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Miyagawa, H., Nakagawa, K. & Kadokami, K. Reproducibility of Programmed-Temperature Retention Indices under Average Linear Velocity Carrier Gas Control of GC and GC–MS. Chromatographia 73, 953–963 (2011). https://doi.org/10.1007/s10337-011-1956-z
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10337-011-1956-z