Abstract
Rapid methods are needed to analyse air pollutants such as polycyclic aromatic hydrocarbons (PAHs). Reliable semi-quantitative gas standards were required for the development of a laser-induced fluorescence (LIF) method for polycyclic aromatic hydrocarbon analysis, based on sampling of air onto multi-channel polydimethylsiloxane rubber traps. Easily constructed diffusion tubes provided naphthalene vapour at ~2 ng s−1. A gas chromatographic fraction collection method for loading less volatile PAHs onto the traps from a flame ionization detector outlet was developed and optimized. The accuracy of the method, which can be further optimized, was sufficient for initial LIF screening tests to flag samples exceeding threshold PAH levels for subsequent quantitative GC–MS analysis.
Similar content being viewed by others
References
Altshuller AP, Cohen IR (1960) Application of diffusion cells to the production of known concentrations of gaseous hydrocarbons. Anal Chem 32(7):802–810
Barratt RS (1981) The preparation of standard gas mixtures. Analyst 106(1265):817–849
Danish Environmental Protection Agency (2002) Environmental Guidelines No. 7, Guidelines on remediation of contaminated sites, Appendix 5.5. Physical and chemical data. Accesed at http://www.mst.dk/udgivetser/publications
Forbes PBC, Rohwer ER (2009) Investigations into a novel method for atmospheric polycyclic aromatic hydrocarbon monitoring. Environ Pollut 157:2529–2535
Lim Ah Tock MJ (2008) Aroma analysis of alcoholic beverages using multi-channel silicone rubber traps. M.Tech. thesis, Tshwane University of Technology
Naganowska-Nowak A, Konieczka P, Przyjazny A, Namieśnik J (2005) Development of techniques of generation of gaseous standard mixtures. Crit Rev Anal Chem 35:31–55
Namieśnik J (1984) Generation of standard gaseous mixtures. J Chromatogr A 300:79–108
Naudé Y, van Aardt M, Rohwer ER (2009) Multi-channel open tubular traps for headspace sampling, gas chromatographic fraction collection and olfactory assessment of milk volatiles. J Chromatogr A 1216(14):2798–2804
Ortner EK, Rohwer ER (1996) Trace analysis of semi-volatile organic air pollutants using thick-film silicone rubber traps with capillary gas chromatography. J High Resolut Chromatogr 19:339–344
Wauters E, Van Caeter P, Desmet G, David F, Devos C, Sandra P (2008) Improved accuracy in the determination of polycyclic aromatic hydrocarbons in air using 24 h sampling on a mixed bed followed by thermal desorption capillary gas chromatography–mass spectrometry. J Chromatogr A 1190:286–293
Acknowledgments
Funding provided by the CSIR, NLC and NRF is gratefully acknowledged.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Forbes, P.B.C., Trüe, A. & Rohwer, E.R. Laser-induced fluorescence of polycyclic aromatic hydrocarbons: an approach to gas standards. Environ Chem Lett 9, 7–12 (2011). https://doi.org/10.1007/s10311-009-0238-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10311-009-0238-6