Introduction

Healthcare-associated infections, especially those caused by methicillin-resistant Staphylococcus aureus strains (HA-MRSA), are a great danger to both hospitalized and immunocompromised patients, in whom the organism causes high morbidity and mortality [1]. S. aureus displays extensive genetic variability. Genotyping analyses, such as multilocus sequence typing (MLST) and protein A (spa) sequence typing, demonstrated that the S. aureus population structure is highly clonal with six major clonal complexes (CCs) (CC1, CC5, CC8, CC22, CC30, and CC45) [24]. Most mobile genetic elements can readily spread horizontally among S. aureus strains of the same clonal cluster, while transfer between clusters is limited. S. aureus strains are generally classified into two classes according to their resistance to β-lactam antibiotics: methicillin-sensitive S. aureus (MSSA) and MRSA strains. One of the resistance mechanisms to β-lactams used by MRSA is based on the production of an alternative penicillin-binding protein (PBP) encoded by the mecA gene; this protein is termed PBP2a. In MRSA, exposure to β-lactams inactivates the four high-binding-affinity PBPs normally present. PBP2a, which displays a low affinity for β-lactams, takes over the functions of these PBPs, permitting the cell to grow. The mecA gene is located on a mobile genetic element integrated into the bacterial chromosome and called the staphylococcal cassette chromosome mec (SCCmec) [5]. Eleven different types of SCCmec, assigned SCCmec I to SCCmec XI, have been defined so far. Most epidemiological investigations focus on types I to VI, and studies on SCCmec types VII to XI are rarely reported [69]. This genetic element is widely used for the determination of MRSA clones. Identification of SCCmec type can be used to predict strain origin, as the majority of nosocomial isolates harbor SCCmec I, II, or III, whereas community-associated MRSA strains (CA-MRSA) are characterized by SCCmec IV and V [810]. Furthermore, it seems that SCCmec element is involved in staphylococcal virulence. It has been shown that SCCmec type-associated virulence factors substantially influence the progression of staphylococcal bacteremia, and SCCmec II S. aureus strains cause the highest morbidity among hospitalized patients [11]. Thus, the determination of SCCmec types, clonal complexes, or spa types may have an important diagnostic value. Whilst no single typing method meets all the requirements for typing techniques, there have been recent trends toward the use of spa, MLST, and SCCmec methods [12]. Large typing databases and networks have been developed to handle the data. The spa typing method is based on sequencing of the polymorphic X region of the protein A gene (spa), present in all strains of S. aureus. The X region consists of a variable number of 24-bp repeats flanked by well-conserved regions. This single-locus sequence-based typing method combines a number of technical advantages, such as rapidity, reproducibility, and portability. Moreover, because of its repeat structure, the spa locus simultaneously indexes micro- and macrovariations, enabling the use of spa typing in both local and global epidemiological studies [13]. The current terminology to describe a lineage is based on multilocus sequence typing (MLST) clonal complexes (CCs). MLST involves sequencing seven housekeeping genes and assigning a sequence type (ST) number to isolates that are identical [12]. MLST is recommended for use in regional laboratories and is a useful tool for defining lineages and scientific analysis. These methods, plus SCCmec, provide the minimum requirements for appropriate molecular epidemiology [12].

The antimicrobial photodynamic therapy (aPDT) has gained increasing importance because of its ability to eradicate a broad spectrum of pathogenic microorganisms [14, 15]. In the clinical area it could be a potential alternative to the antibiotics used to treat staphylococcal infections. The photodynamic process involves the combined use of light, molecular oxygen, and a photosensitive compound (photosensitizer) [16]. This interaction leads to production of reactive oxygen species and free radicals responsible for oxidation of many biological molecules (enzymes, proteins, lipids, and nucleic acids), leading to cell death [17]. Additionally, the resistance mechanisms towards photodynamic inactivation have not yet been observed [18, 19]. However, our studies of the photoinactivation (PDI) of multiresistant pathogenic bacteria have shown that the effectiveness of PDI is strain-dependent and that one should search for possible strategies to overcome resistant phenotype, but, on other hand, to develop the diagnostic tool clustering strains according to their susceptibility to PDI [2024]. The mechanism underlying this phenomenon is still poorly understood. Thus, by applying SCCmec typing and collecting the isolates representing different spa genotypes and clonal clusters, we aimed, in particular, to assess the contribution of the bacterial genetic background in S. aureus response to photodynamic oxidation.

Materials and methods

Bacterial isolates

In total, 438 S. aureus strains (418 MRSA and 20 MSSA) were used. Of them, 321 clinical MRSA strains were isolated between 2002 and 2012 at the Provincial Hospital in Gdansk and Hospital in Koszalin (Poland) and were previously characterized. The isolates were characterized by Gram staining and the ability to produce coagulase and the clumping factor using Slidex Staph Plus (bioMèrieux, France) and were re-identified to the species level using the MALDI-TOF MS (Bruker Daltonics, Germany). Methicillin resistance was determined using a disc-diffusion method as well as a latex test detecting PBP2a protein (Staphytect Plus; Oxoid, Lenexa,KS, USA) [25]. Of the 321 strains collected, 40.5 % (130 isolates) were isolated from surveillance cultures, 46.4 % (149 isolates) from patients with local infections, 11.8 % (38 isolates) from patients with bacteremia and generalized infections and 1.3 % (4 isolates) from infections connected with endoprostheses. An additional 97 MRSA and 20 MSSA isolates, with identified CCs and spa type were obtained through the Network of Antimicrobial Resistance in Staphylococcus aureus (NARSA), Staphylococcus Laboratory, Statens Serum Institute in Denmark, Centre for Clinical Infection and Diagnostics Research in the UK, University of Oviedo in Spain, and National Medicines Institute in Poland. The strains are listed in Online Resource 1. Clonal complexes (CC) were determined with the use of MLST. All clonal complexes, excluding CC8, were represented by single ST. CC8 included strains with ST8 and ST247. Additionally, the reference strains of S. aureus listed in Table 1 were used to optimize SCCmec type determination. The abundance of S. aureus isolates in each group is provided in Table 2. The molecular characteristics of isolates are provided in Table 3.

Table 1 Primers and reference strains used in the study
Table 2 Distribution of methicillin-resistant Staphylococcus aureus (MRSA) isolates by typing procedures
Table 3 Molecular characteristics of MRSA isolates

MALDI-TOF MS

Three hundred and twenty-one S. aureus clinical strains isolated from hospitals in Poland were examined by MALDI-TOF MS using a Microflex LT instrument (Bruker Daltonics, Leipzig, Germany), Flexcontrol 3.0 software and the Biotyper 2.0 database (Bruker Daltonics, Germany). The data analysis was performed according to the manufacturer’s instructions. The samples were covered with 1 ml matrix solution (a saturated solution of a-cyano-4-hydroxycinnamic acid in 50 % acetonitrile, 2.5 % trifluoroacetic acid). The analyzed mass range of spectra was 2,000–20,000 m/z. Each spectrum was obtained after 240 shots in an automatic acquisition mode. For the identification approach, a mass-to-charge range of 3,000–15,000 Da was used. Identification was performed in duplicate and the higher score was retained. The identification score cut-off values were applied on each measurement according to the manufacturer’s instructions. According to this score system, a score of < 2 is recommended for a probable species and a score of greater than 2.3 is recommended for a secure species identification [26].

Nucleic acid isolates

For DNA isolation, strains were grown overnight in nutrient trypticase soy broth (TSB) (bioMèrieux, France) at 37 °C for 24 h. Then, 1.5 ml of the bacterial culture was centrifuged at 5000 x g for 10 min. The pellet was suspended in 180 μl of lysis buffer (20 mM Tris–HCl, pH 8.0, 2 mM EDTA, 1.2 % Triton X-100, lysozyme 20 mg/ml) and the GeneJET™ Genomic DNA Purification Kit (Thermo Scientific, Vilnius, Lithuania) was used for DNA isolation according to the manufacturer’s procedure. The DNA concentrations were measured using NanoDrop ND-1000 (Thermo Scientific) and were within the range 10 to 100 ng/μl. In addition, the quality of the isolated DNA was confirmed by gel electrophoresis.

SCCmec type-specific multiplex PCR

A two-tube multiplex PCR method was performed to identify the SCCmec types from the MRSA isolates [27]. One tube was used to determine SCCmec types I, II, III, and V, and one tube was used to determine SCCmec types IVa, IVb, IVc, IVd, and IVh. In the first reaction, the Sa442 and mecA genes were also amplified as a control. Sa442 is a gene specific to S. aureus, and mecA encodes the alternate penicillin-binding protein responsible for beta-lactam resistance. The two-tube reactions were performed in a 25-μl reaction mixture containing 4 μl of the purified nucleic acid solution, 1 U of DyNAzyme™ EXT Taq DNA Polymerase (Thermo Scientific), 10X DyNAzyme™ EXT Buffer (Thermo Scientific), 200 μM dNTPs (MetaBion, Martinsried, Germany), and SCCmec group-specific primers. For the first tube reactions, a 2-μM concentration of SCC I primers were used along with a 0.4 μM concentration of the primers for mecA, Sa442, SCC II, SCC III, and SCC V (primers listed in Table 1). For the second tube reactions, 2 μM concentrations of the primers for SCC IV were used (primers listed in Table 1). Amplifications were performed in an Applied Biosystems thermocycler (GeneAmp® PCR System 9700) using the following temperature program: 1 cycle of 4 min at 95 °C; 30 cycles of 30 s at 94 °C, 1 min and 30 s at 57 °C, 1 min and 30 s at 72 °C, and a final cycle of 10 min at 72 °C. Amplification products were electrophoresed in a 1.8 % agarose gel (BIORON, Ludwigshafen, Germany) containing ethidium bromide and visualized by transillumination (Gel Doc 2000; Bio-Rad) under UV irradiation [27].

Photosynthesizer

Protoporphyrin IX (PPIX) (MP Biomedicals, LLC, USA) was used as a sensitizer. PPIX was dissolved in dimethyl sulfoxide (DMSO; Sigma, Germany) to make a 1-mM stock solution and was stored in the dark at −20 °C until use. The concentration of the photosensitizer was determined spectrophotometrically (extinction coefficient 1.6 x 105 M−1 cm−1, wavelength 408 nm).

Light source

Illumination was performed using a Q.Light® PDT Lamp (b & p® Schweiz AG, St Gallen, Switzerland) (ISO 9001 and EN 46001—CE 1275; power of lamp 80 mW; fluence rate 102 mW/cm2; fluence 6.12 J/cm2 per minute). The delivered light energy was determined with the use of a light power meter (model LM1; Carl Zeiss, Oberkochen, Germany). The Q.Light® PDT Lamp emits polarized light (polarization level: 98 %) over a wavelength range of 620 to 780 nm.

PDI studies

Three hundred and twenty-one isolates were already characterized regarding their response to photodynamic inactivation. One hundred and seventeen newly collected S. aureus strains (97 MRSA and 20 MSSA isolates) were subjected to photodynamic inactivation (PDI). Bacterial cultures were grown overnight (24 h) at 37 °C in nutrient trypticase soy broth (bioMèrieux, Craponne, France) and then diluted with fresh broth to an appropriate density (107/ml bacterial cells) based on densitometry (Densi Meter II, EMO). Diluted S. aureus cultures were incubated with 25 μM protoporphyrin IX in the dark at 37 °C for 30 min. The cells were then transferred to a 96-well microtiter plate (100 μl per well) and illuminated with appropriate light (50 J/cm2) at room temperature for 8 min and 10 s. Following illumination, 10 μl aliquots were used to determine the colony forming units (CFU). The contents of the wells were mixed before sampling, and the aliquots were serially diluted 10-fold in PBS (0.13 mM NaCl, 8.1 mM Na2HPO4, 2.68 mM KCl, 1.47 mM KH2PO4) to achieve final dilutions of 10−1 to 10−4, which were then streaked horizontally onto square trypticase soy agar plates [28]. The plates were incubated at 37 °C overnight. Controls consisted of untreated bacteria (no photosensitizers or light) kept in 96-well plates for the duration of the illumination. After 18 h of incubation at 37 °C in the dark, CFUs were counted and the results were statistically analyzed. Survival fractions were expressed as ratios of CFUs of treated bacteria (with light and photosensitizer) to CFUs of untreated bacteria. The experiment was performed three times.

Statistical analysis

The statistical analyses have been performed using the statistical suite StatSoft (2011) Statistica (data analysis software system) version 10.0. www.statsoft.com and Excel. The quantitative variables were characterized by the arithmetic mean of standard deviation or median or maximum/minimum (range) and 95 % confidence interval. The qualitative variables were presented with the use of count and percentage. Statistical significance of differences between two groups (unpaired variables model) was processed with the Student’s t test. The significance of difference between more than two groups was assessed using F test (ANOVA). In all the calculations the statistical significance level of p < 0.05 has been used.

Results

Heterogeneous response of S. aureus to PDI

The different strains expressed a heterogeneous response to photoinactivation, ranging from 0 to 4.51 log10-unit reductions in viable counts under the same experimental conditions. According to lethal or sub-lethal damage caused by PDI treatment, the strains were classified as sensitive or resistant PDI responders (cut-offs for the categorization presented in Table 4). Strains revealing reduction in viable counts ranged between lethal and sub-lethal damage were assigned as intermediate-sensitive (Table 4).

Table 4 Range of effectiveness of photosensitization of MRSA isolates

The SCCmec element does not have an impact on PDI response

To determine if any relationship exists between the PDI response and the type of SCCmec, SCCmec typing was performed for 321 clinical MRSA strains (for the rest of the 97 isolates SCCmec types had already been characterized). The results showed that for the MRSA strains studied, the distribution of PDI responders among the five different groups classified according to SCCmec types is similar (Fig. 1). The same conclusion could be drawn when comparing the distribution of uncategorized values of responses to PDI across S. aureus groups with different SCCmec types (Fig. 2). We can therefore conclude that the type of SCCmec element has no impact on the strain’s response to PDI and could not classify strains according to their response to photodynamic treatment.

Fig. 1
figure 1

Distribution of methicillin-resistant Staphylococcus aureus (MRSA) S. aureus clusters (staphylococcal cassette chromosome (SCC)mec types, clonal complexes and spa types) in photoinactivation (PDI) categories. R PDI-resistant strains, IS PDI-intermediate-sensitive strains, S PDI-sensitive strains

Fig. 2
figure 2

Response to protoporphyrin IX (PPIX)-mediated PDI of S. aureus strains with various types of SCCmec element. Each box plot represents the spread of bacterial response across different clinical isolates. The error bars represent minimum and maximum values of log10-unit reduction in viable counts

Susceptibility to photodynamic oxidation and clonal complex

Four-hundred eighteen MRSA isolates varied in their response to photodynamic inactivation. The results showed that for the MRSA strains studied, the distribution of PDI responders among the seven different groups classified according to clonal complex is different (Fig. 1). Interestingly, all CC1 S. aureus strains (n = 5) were identified as PDI-resistant isolates. Conversely, all CC30 isolates (n = 3) were characterized as PDI-sensitive or -intermediate-sensitive strains (Fig. 1). Also, the percentage of CC45 isolates increased in accordance with susceptibility to photoinactivation (Fig. 1; not statistically significant analysis). When analyzing the un-categorized values of response to PDI, clonal complex typing revealed significant differences in S. aureus response according to its genetic background (Fig. 3). Strains belonging to CC1 showed strict association with resistance to photoinactivation, whereas CC30 and CC8 (ST247) isolates were in general susceptible to PDI (Fig. 3). As different behavior was observed for strains CC8 according to their STs, ST number was provided in parenthesis (ST8 and ST247 respectively). Number of isolates representing each clonal complex is provided in Table 2. Results obtained indicated possible association of CC-mediated determination of genetic background and susceptibility to photodynamic oxidation.

Fig. 3
figure 3

Response to PPIX-mediated PDI of S. aureus strains from various clonal complexes. Each box plot represents the spread of bacterial response across different clinical isolates. The error bars represent minimum and maximum value of log10-unit reduction in viable counts

Susceptibility to photodynamic oxidation and spa types

Determination of genetic background with spa typing also indicated its association with susceptibility to photodynamic inactivation as statistically different PDI responses were observed in respect of spa types (Fig. 4). Interestingly, spa typing led to distinguishing the CC45 cluster into PDI-sensitive and -intermediate-sensitive strains. When analyzing solely the clonal complex, isolates belonging to CC45 generally showed intermediate sensitivity to photodynamic treatment (Fig. 3). When applying spa typing, the differentiation of PDI-sensitive strains was observed (t015) (Fig. 4). This spa type was detected exclusively within CC45 (Table 3). The analyses of distribution of PDI responders across different spa types also revealed that the percentage of t015 and t051 isolates increased in accordance with susceptibility to photoinactivation (Fig. 1). Conversely, the percentage of t064 isolates increased in accordance with resistance to PDI (Fig. 1). These observations indicated the possible association of genetic background of S. aureus isolates with susceptibility to photodynamic oxidation (not statistically significant analysis).

Fig. 4
figure 4

Response to PPIX-mediated PDI of S. aureus strains with various spa types. Each box plot represents the spread of bacterial response across different clinical isolates. The error bars represent minimum and maximum value of log10-unit reduction in viable counts

Similar PDI response across MRSA and MSSA strains belonged to CC22 and CC45

To investigate whether the same susceptibility and/or resistance to photoinactivation could be observed in S. aureus isolates regardless of MRSA or MSSA status, the PDI response was analyzed in MRSA and MSSA isolates belonging to the same genetic background. Interestingly, the response of CC22 and CC45 S. aureus isolates was the same in the MRSA and MSSA groups indicating that the associations observed are independent of presence of SCCmec element (Fig. 5).

Fig. 5
figure 5

Response to PPIX-mediated PDI of MRSA and MSSA strains belonging to the same clonal clusters. Each box plot represents the spread of bacterial response across different clinical isolates. The error bars represent minimum and maximum value of log10-unit reduction in viable counts

Discussion

Recently we demonstrated that a strain-dependent response of S. aureus to PDI exists, although the underlying mechanism remains unexplained [22, 23, 29]. The current study aimed to investigate statistically relevant correlations between the genetic backgrounds of methicillin-resistant S. aureus strains and their response to photodynamic inactivation. Thus, evaluation of response to photodynamic treatment in distinct clonal lineages of S. aureus was performed.

It might be concerning that the concentration of DMSO used in the experiments could affect the results obtained. Ghajar and Harmon [30] studied the influence of DMSO on the permeability of S. aureus, demonstrating that DMSO increased the oxygen uptake, but reduced the rate of glycine transport. DMSO exerts a marked inhibitory effect on a wide range of bacteria and fungi. For S. aureus, the minimal inhibitory concentrations of DMSO vary between 20 and 30 % and minimal bactericidal concentrations are above 30 % [31]. 2.5 % DMSO (used in the current study) is not lethal but is high enough to possibly alter membrane permeability depending on the surface protein concentration [30, 32]. To exclude the possible impact of DMSO on PPIX uptake, the intracellular concentration of DMSO-soluble PPIX and water-soluble PPIX derivative (protoporphyrin diarginate, PPArg2) was measured after 30 min incubation at 37 °C. The level of PPArg2 uptake was measured previously [33]. The intracellular uptake of both PPIX and PPArg2 was similar (35 vs 38 μg per mg of bacterial protein) indicating that 2.5 % DMSO did not affected the intracellular uptake of sensitizers [33]. It is worth emphasizing that photodynamic treatment including porphyrin derivatives sensitizers, could utilize DMSO concentrations of up to 25 %, revealing that the 2.5 % DMSO used in the current study is in fact a very low dose [34]. Thus, we can conclude that the differences observed in S. aureus response to PPIX-mediated photoinactivation are not affected by the 2.5 % DMSO used.

Previously, we have shown that MRSA strains were found to have a generally higher percentage of PDI resistance than MSSA strains [22]. This result suggested that PDI resistance may be related to multidrug-resistance in MRSA strains, thus prompting our investigation of the staphylococcal cassette chromosome mec element. The data obtained during this study allowed us to conclude that the SCCmec element has no effect on the strain response to PDI, as there were no statistically significant differences between SCCmec types and the response to PDI. Thus, we can assume that the observed phenomenon of a higher number of PDI-resistant strains within the MRSA group is a secondary effect not directly connected to antibiotic resistance. The same conclusion could be drawn when comparing the susceptibility to PDI in MRSA and MSSA groups belonging to the same clonal complexes (Fig. 5).

Different SCCmec elements may be observed in virtually identical genetic backgrounds, and conversely, strains from completely different clonal complexes may acquire the same SCCmec elements (Table 3) [35]. Thus, it was necessary to further investigate the possible association of susceptibility to PDI with clonal complexes or spa clusters. This study revealed that elevated resistance of S. aureus to PDI could be associated with clonal complex CC1 and observed in 100 % of these isolates. Furthermore, clustering the isolates into clonal complexes and spa types led to identification of PDI-sensitive S. aureus lineages. The most PDI-sensitive isolates were characterized within CC30 and spa types t015 and t051. However, one must remember that in the current study the number of representatives in some spa types was too low to draw statistically relevant conclusions and further investigations should be performed to indicate evidence-based associations.

In summary, the present study revealed that particular genetic backgrounds could be a predisposing factor for elevated resistance to photodynamic treatment. Results of the present study corroborate the potential of CC typing procedure that could be applied to disclose the major lineages represented in S. aureus collection and to detect the PDI-resistant phenotypes. These can then be further identified accurately by other powerful techniques, such as spa typing.

It is significant to underline that the resistance mechanisms toward photodynamic inactivation have not yet been observed [18, 19]. The phenomenon that is described within the current paper concerns resistant phenotypes; thus, applying more rigorous photodynamic conditions (like a higher light dose or sensitizer concentration) this resistance could be overcome. Nevertheless, it is clinically relevant to identify isolates requiring stricter conditions to adjust the photoinactivation procedure ensuring a successful therapeutic effect. We believe that enhanced investigation concerning the association of S. aureus genetic background with susceptibility to photodynamic inactivation could lead to precise identification of PDI-resistant phenotypes. These studies should include more numerous groups of clonal clusters with respect to clonal complex and other spa types. Moreover, it is important to make it clear that aPDT efficacy depends on the ability of the photosensitizer and light to penetrate bacterial membranes; thus, more studies must be carried out using other types of sensitizing agents to prove the same behavior.

S. aureus infections continues to be a growing burden for the healthcare system. The latest epidemiological data suggest that this problem will continue to grow as the number of at-risk patients rises. Moreover, antibiotic resistance spreads from healthcare settings to the community and the development of alternative therapeutic approach is needed. One of the possibilities could be photodynamic inactivation; however, it is also not without limitations. One is the existence of PDI-resistant phenotypes that require more rigorous treatment conditions to achieve the total eradication. To improve the therapeutic outcome an effort is needed in prediction of isolate response to photodynamic treatment including a better diagnostic of resistant phenotypes. The strategies to overcome PDI-resistant phenotypes as well as mechanisms leading to PDI resistance have been described elsewhere [21, 29, 36]; however, the impact of genotypic background on the susceptibility of different strains to PDI remains unexplored and should be a field of great interest in the future as it could have a significant clinical impact.