Abstract
Few descriptions of the implantation and management of an implantable ventricular assist device in patients with complex congenital heart disease exist in the literature. The Jarvik 2000 axial-flow ventricular assist device (Jarvik Heart, Inc., NYC, NY, USA) can be placed in either the left or the right ventricle. We present the case of a 60-year-old man with congenitally corrected transposition of the great arteries who underwent successful placement of a Jarvik 2000 axial-flow ventricular assist device in a systemic morphologic right ventricle.
Similar content being viewed by others
References
Huang J, Slaughter MS. HeartWare ventricular assist device placement in a patient with congenitally corrected transposition of the great arteries. J Thorac Cardiovasc Surg. 2013;145:e23–5.
Rajagopalan N, Booth DC, Diaz-Guzman E, Hoopes CW. Successful ventricular assist device placement in transposition of the great arteries with pulmonary hypertension. Ann Thorac Surg. 2013;95:e47.
Huebler M, Stepanenko A, Krabatsch T, Potapov EV, Hetzer R. Mechanical circulatory support of systemic ventricle in adults with transposition of great arteries. ASAIO J. 2012;58:12–4.
Mohite PN, Popov AF, Garcia D, Hards R, Zych B, Khaghani A, Simon AR. Ventricular assist device outflow graft in congenitally corrected transposition of great arteries—a surgical challenge. J Cardiothorac Surg. 2012;7:93–5.
Joyce DL, Crow SS, John R, St Louis JD, Braunlin EA, Pyles LA, Kofflin P, Joyce LD. Mechanical circulatory support in patients with heart failure secondary to transposition of the great arteries. J Heart Lung Transplant. 2010;29:1302–5.
Jarvik R. Jarvik 2000 pump technology and miniaturization. Heart Fail Clin. 2014;10:S27–38.
Saito S, Sakaguchi T, Sawa Y. Clinical report of long-term support with dual Jarvik 2000 biventricular assist device. J Heart Lung Transplant. 2011;30:845–7.
Wang TS, Hernandez AF, Felker GM, Milano CA, Rogers JG, Patel CB. Valvular heart disease in patients supported with left ventricular assist devices. Circ Heart Fail. 2014;7:215–22.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Rights and permissions
About this article
Cite this article
Tanoue, Y., Jinzai, Y. & Tominaga, R. Jarvik 2000 axial-flow ventricular assist device placement to a systemic morphologic right ventricle in congenitally corrected transposition of the great arteries. J Artif Organs 19, 97–99 (2016). https://doi.org/10.1007/s10047-015-0866-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10047-015-0866-5