Prevention of pacemaker-associated contact dermatitis by polytetrafluoroethylene sheet and conduit coating of the pacemaker system

  • Case Report
  • Pacemaker
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

A 73-year-old female with sick sinus syndrome and atrial fibrillation was implanted with a ventricular demand inhibit pacemaker. She subsequently developed multiple episodes of skin irritation and necrosis. Skin patch testing revealed sensitivity to almost every component of the pacemaker system. The pacemaker was removed and replaced with a new pacemaker in which the generator was covered with a polytetrafluoroethylene (PTFE) sheet and the lead was covered with PTFE conduit. The patient suffered no further episodes of pacemaker-associated contact dermatitis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

References

  1. Raque C, Goldschmidt H. Dermatitis associated with an implanted cardiac pacemaker. Arch Dermatol. 1970;102:646–9.

    Article  CAS  PubMed  Google Scholar 

  2. Peters MS, Schroeter AL, van Hale HM, Broadbent JC. Pacemaker contact sensitivity. Contact Dermat. 1984;11:214–8.

    Article  CAS  Google Scholar 

  3. Hayes DL, Loesl K. Pacemaker component: case report and review of the literature. J Interv Electr. 2002;6:277–8.

    Google Scholar 

  4. Yamauchi R, Morita A, Tsuji T. Pacemaker dermatitis from titanium. Contact Dermat. 2000;42:52–3.

    CAS  Google Scholar 

  5. Rikke S, Carsten T, Poul EB-T. Epoxy contact dermatitis due to pacemaker compounds. Cardiology. 2003;99:112.

    Article  Google Scholar 

  6. Dery JP, Gilbert M, O`Hara G, Champagne J, Desaulniers D, Chatier P, Philippon F. Pacemaker contact sensitivity: case report and review of the literature. J Pacing Clin Electr. 2002;25:863–5.

    Article  Google Scholar 

  7. Iguchi N, Kasanuki H, Matsuda N, Shoda M, Ohnishi S, Hosoda S. Contact sensitivity to polychloroparaxylene-coated cardiac pacemaker. Pace. 1997;20:372–3.

    Article  CAS  PubMed  Google Scholar 

  8. Ishii K, Kodani E, Miyamoto S, Otsuka T, Hosone M, Ogawa K, Sato W, Matsumoto S, Tadera T, Ibuki C, Kusama Y, Atarashi H. Pacemaker contact dermatitis: the effective use of a polytetrafluoroethylene sheet. Pace. 2006;29:1299–302.

    Article  PubMed  Google Scholar 

  9. Tameishi A, Usui A, Oshima H, Ueda Y. Entirely polytetrafluoroethylene coating for pacemaker system contact dermatitis. Interact Cardiovasc Thorac Surg. 2008;7:275–6.

    Article  Google Scholar 

  10. Yashiro B, Shoda M, Tomizawa Y, Manaka T, Hagiwara N. Long-term results of a cardiovascular implantable electronic device wrapped with an expanded polytetrafluoroethylene sheet. J Artif Organs. 2012;15:244–9.

    Article  CAS  PubMed  Google Scholar 

  11. Hayes DL, Friedman PA. Implantation-related complications. In: Hayes DL, Friedman PA, editors. Cardiac pacing, defibrillation and resynchronization: a clinical approach. 2nd ed. West Sussex: Willey; 2008. p. 202–33.

    Chapter  Google Scholar 

  12. Bourke J, Coulson I, English J. Guidelines for care of contact dermatitis. Br J Dermatol. 2001;145:877–85.

    Article  CAS  PubMed  Google Scholar 

Download references

Conflict of interest

We have no financial or other interest in the manufacture or distribution of the device.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Takahiro Taguchi.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Taguchi, T., Maeba, S. & Sueda, T. Prevention of pacemaker-associated contact dermatitis by polytetrafluoroethylene sheet and conduit coating of the pacemaker system. J Artif Organs 17, 285–287 (2014). https://doi.org/10.1007/s10047-014-0775-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-014-0775-z

Keywords

Navigation