Introduction

The detailed characterization of preferential flow in fractured bedrock aquifers is important for the water resource management as well as the investigation of contaminant pathways (Neuman 2005). Because a fractured rock aquifer is heterogeneous and anisotropic, the delineation of flow paths is much more difficult than in an unconsolidated aquifer, resulting in a relatively poor understanding of how groundwater flow occurs in the fractured rock aquifer. Borehole geophysical techniques usually investigate permeable zones based on the distribution of fractures (Barton et al. 1995; Williams and Johnson 2000). However, groundwater is often found to flow through only a few permeable fractures (Berkowitz 2002). The distribution of hydraulic conductivity in an open hole can be estimated from a packer test (Braester and Thunvik 1984; Zhao 1998), but its operation is time-consuming and its resolution is restricted to the test interval. Electrical conductivity logging can be used to detect the permeable zones in a borehole (Tsang et al. 1990). Recent development of the distributed temperature sensing technology can be used to characterize the permeable fractures and hydrogeological conditions in a single borehole (Banks et al. 2014; Read et al. 2014; Coleman et al. 2015; Bense et al. 2016; Sellwood et al. 2016), but the deployment of the downhole instrument may affect data acquisition (Bense et al. 2016; Sellwood et al. 2016). Heat-pulse flowmeter test can effectively investigate the vertical distribution of transmissive zones in the bedrock aquifer (Molz et al. 1994; Lee et al. 2012). The flowmeter test has also been used to indirectly infer the flow paths between boreholes (Williams and Paillet 2002).

The solute tracer test was performed to delineate a single fracture in field experiments with comprehensive well-logging data (Novakowski and Lapcevic 1994; Lapcevic et al. 1999), but frequent sampling and analysis is expensive and time consuming. The hydraulic tomography approach can be used to indirectly infer the fracture connectivity (Hao et al. 2008; Sharmeen et al. 2012; Zha et al. 2014, 2015, 2016); however, spatial resolution of the inferred tomograms is controlled by the observation interval. Thermal tracer tests have been conducted to delineate fracture flow paths between boreholes (Ma et al. 2012; Read et al. 2013; Klepikova et al. 2014). The method can be used to detect the most transmissive fracture, but is not sensitive to identifying all flowing fractures in the borehole (Klepikova et al. 2014). Additional processes involved in heat transport and significant noises make it difficult to quantitatively interpret the temperature data from the thermal tracer experiment (Ma et al. 2012).

Nanoscale zero-valent iron (nZVI), an effective reducing reagent, has been used to remediate and remove various groundwater contaminants, such as chlorinated organic solvents, organochlorine pesticides, and PCBs (Wang and Zhang 1997; Varanasi et al. 2007). Chuang et al. (2016) developed an approach using nZVI particles as tracers to directly locate flow paths in fractured rock; however, most injected nZVI particles were found to aggregate and precipitate to the bottom of the injection well, resulting a low mass recovery rate of approximately 0.01%. This would restrict the potential application of nZVI particles as tracers beyond the experimental range.

In this study, an improved nZVI tracer test was developed to characterize the flow paths in fractured rock. A laboratory flow system was established to examine the migration characteristics of nZVI slurry. Preliminary field tests at the study site were conducted for the design of the tracer tests. Two tracer tests were then conducted between a sealed injection well and an observation well with slotted casing, including a conventional saline tracer and a novel nZVI tracer, to compare test results. Lastly, a numerical model using MODFLOW with MT3DMS was developed to simulate the tracer transport through permeable fracture zones at the study site.

Synthesis of nanoscale zero-valent iron

nZVI particles were prepared by a chemical reduction method (Wang and Zhang 1997). Typically, nZVI can be synthesized by using sodium borohydride as the key reductant. The reaction was carried out by adding 0.5 L of NaBH4 (1.74 M) to 0.5 L of FeCl· 6H2O (0.3 M) solution at a volume ratio of 1:1. Ferric iron is reduced by borohydride according to the following reaction:

$$ 4{\mathrm{Fe}}^{3+}+3{\mathrm{BH}}_4^{-}+9{\mathrm{H}}_2\mathrm{O}\to 4{\mathrm{Fe}}^0\downarrow +3{\mathrm{H}}_2{\mathrm{BO}}_3^{-}+12{\mathrm{H}}^{+}+6{\mathrm{H}}_2 $$
(1)

Due to magnetic attraction and van der Waals forces, nZVI particles can form aggregates and precipitate in a gelatinous state (Comba and Sethi 2009). Previous studies indicated that many surface-active agents can be used to make dispersible ink and toner (Williams et al. 2006; Phenrat et al. 2008). In this study, water-soluble polyethyleneimine (PEI) was used as a nanoparticle dispersant. PEI is a polymer that can provide the steric repulsive forces to form a colloidal suspension and reduce the aggregation of nZVI particles (Goon et al. 2009; Wang et al. 2009). Here, the PEI was mixed to a concentration of approximately 4 × 10−4 M. Most of the nZVI particles produced in this study ranged from 50 to 100 nm in diameter. The solid content of the PEI-stabilized nZVI particles was about 8.6 g Fe/L.

The laboratory synthesized nZVI slurry was composed of water, nZVI particles and water-soluble PEI. Previous studies (Phenrat et al. 2008; Tiraferri et al. 2008) indicated that nZVI particles were settled and fractionated by gravity in solution. Immediately after the synthesis of nZVI particles, they were observed to move downward. An interface between the supernatant and the subnatant was formed in 5 min and stabilized in less than 30 min. The brown-colored supernatant consisted of water, some PEI, a small amount of ferric oxide particles, and nZVI particles. The dark-colored subnatant consisted primarily of nZVI particles and PEI. nZVI particles settled to the bottom due to gravity effect, while PEI settled due to increased density from the aggregation of PEI molecules through short-range hydrogen bonds (Sidorov et al. 1999). Nearly all deposited nZVI particles were soaked in the PEI solution. Electrical conductivities of the PEI is approximately 2,100 μS/cm. After the nZVI particles were added to the PEI, electrical conductivity of the well-mixed nZVI slurry increased to 3,120 μS/cm. After the gravitational segregation, electrical conductivity of the supernatant reduced to 328 μS/cm. Last, and most importantly, as nZVI particles are magnetic, they are attracted to magnets. This feature spurred the development of a magnet array for locating the position of incoming tracers. The magnet array assembly, which is used in both laboratory and field tests, consists of a 2-mm steel cable, centralizers, and a number of neodymium magnets. There is an interval of 10 cm between the magnets and 1 m between the centralizers. The size of the magnet is 2.95 × 1.25 cm.

Laboratory test

A laboratory test was contrived to simulate the migration processes of the nZVI slurry between two open holes connected by a single permeable fracture. Two 9.4-cm diameter transparent acrylic vertical pipes were set up to simulate the injection and observation wells. A 40-cm-long horizontal transparent acrylic pipe was placed to connect the two vertical pipes at 24.8–28.9 cm above the bottom, as shown in Fig. 1. The horizontal pipe was filled with well-sorted fine sand to simulate a permeable conduit. An overflow condition resulted in a constant difference in hydraulic head of 20.4 cm between the two pipes, yielding an average hydraulic gradient of 0.51. Two electrical conductivity sensors were placed respectively at the bottom of the injection pipe and 27.9 cm above the bottom, right adjacent to the permeable conduit, in the observation pipe. In addition, a 40-cm long magnet array, including four pieces of magnets was installed in the observation pipe. The flow system was run for 16 days to minimize instabilities caused by the compaction of the filling sand. After stabilization, the discharge rate through the observation pipe was 0.087 ml/s.

Fig. 1
figure 1

Laboratory system for the nZVI tracer test. a Schematic diagram of test results 4 days after the injection of nZVI slurry. The inset shows a transmission electron microscopy (TEM) image of chain-like aggregated nZVI particles. b Weight profile of nZVI particles attracted to the magnet array in the observation pipe

A total of 1.3 L of nZVI slurry consisting of approximately 11.1 g of nZVI particles was released into the injection pipe, and then water was continuously injected to stabilize the flow field throughout the laboratory test. Immediately after the tracer injection, most of the nZVI slurry was observed to move downward to the bottom. Only a tiny amount, approximately 31 ml, migrated into the permeable conduit in the first 6 min. The fluid in the upper part of the pipe turned from opaque to translucent, while the fluid at the bottom turned dark. Such a phenomenon suggested the occurrence of settlement of most dark-colored nZVI particles at the bottom of the injection pipe. An interface was formed between the supernatant and the subnatant near the bottom. In addition, another interface formed between the diluted brown-colored PEI slurry and the follow-up fresh water at 58 cm above the bottom approximately 40 min after the injection. The interface slowly descended due to the flow of the slurry into the permeable conduit and settled at 24.7 cm above the bottom and just below the permeable conduit at 490 min. It remained at this level during the following 6 months until the end of the laboratory test. Most nZVI particles formed chain-like micrometer-size clusters and deposited at the bottom of the injection pipe, and they remained as zero-valent irons even 6 months later, as shown in the inset of Fig. 1a.

A brown-colored viscous fluid was observed to reach the observation pipe approximately 35 min after the injection. This was followed by a rapid increase in electrical conductivity at the observation pipe, suggesting the arrival of injected nZVI slurry. The arriving fluid immediately was observed to move spirally downward to the bottom of the observation pipe due to the density effect. With increasing amounts of nZVI slurry, an interface between the slurry and fresh water appeared in the observation pipe. The interface rose slowly up to 24.7 cm above the bottom, as shown in Fig. 1a.

The magnet array was retrieved 4 days later to examine the weight distribution of nZVI particles attracted to the four separate magnets. The total weight of attracted nZVI particles was 0.2963 g and the mass recovery was approximately 2.67% of the injected weight of nZVI particles (Fig. 1b). It was noted that most of the accumulated nZVI particles, approximately 0.2356 g, were attracted to the magnet closest to the permeable conduit located at 27.9 cm above the bottom. The nZVI particles were also found on other magnets, but the accumulated weight decreased significantly with increasing distance from the conduit.

Laboratory test results indicated that the magnet array is a useful device for detecting the incoming nZVI particles. However, most of the nZVI particles settled at the bottom of the injection pipe, reducing the mass recovery rate; therefore, in the field test, a sealed well was used for the tracer injection to limit the flow of the nZVI slurry to a narrow permeable segment. Compared with the injection in an open borehole, this approach can reduce the space below the connected fractures in the injection well and prevent the injected nZVI particles from settling to the bottom of injection well, improving the mass recovery of the nZVI tracer in the observation well.

Field experiments

Experimental wells

At the Heshe Experimental Forest of National Taiwan University in central Taiwan, a hydrogeological research station was established in fractured rock. The station covers an area of about 200 m2 near the bank of the Chenyoulan River. It is located 775 m above sea level in the pediment area of Wangma Mountain. Groundwater flows to the east with a mean gradient of 0.01 approximately under natural conditions.

Ten wells were drilled on site to conduct various hydrogeological studies in fractured rock (Wang et al. 2015). Of these, two experimental wells, W4 and W6, were used for this study. The distance between the two wells is 2.57 m. The core logging indicated that the colluvial overburden is underlain by dark-gray shale and siltstone (Fig. 2). The overburden, extending from the surface to 18–19.5 m in depth, is primarily composed of unconsolidated sand and rock debris. The water table was approximately 9 m below the ground surface. W4 is a 45-m deep well cased and sealed from the surface to the depth of 21.5 m, and screened with a 10.16-cm diameter slotted screen from the depth of 21.5–45 m. W6 is a 35-m deep well cased to the depth of 21.5 m and open below. Before the tracer tests, a 2.8-cm diameter tubing screened at the depth between 31 and 32.5 m was inserted into injection well W6.

Fig. 2
figure 2

Experimental wells and their geometric characteristics

Preliminary field tests

Two hydraulic tests were performed to investigate the hydraulic connectivity between W4 and W6 (Fig. S1 of the electronic supplementary material (ESM); see the ESM for detailed information of hydraulic tests and heat-pulse flowmeter tests). The results revealed hydraulic connectivity between the two wells. Then flowmeter tests were conducted to characterize the vertical distribution of permeable zones for locating the screened depth of the injection well. According to flowmeter measurements, the transmissivity in each 25-cm section varied with depth (Fig. S2 of the ESM). Two permeable zones were identified respectively at depths of 23.5–24 and 28–29 m in well W4. In well W6, three permeable zones were located respectively at depths of 24–25, 29.5–29.75 and 33–33.5 m (Fig. S3 of the ESM); the most permeable one was located at 33–33.5 m.

Results of the hydraulic tests suggested that wells W4 and W6 were hydraulically connected by permeable fractures. The most permeable zone at the depth of 33–33.5 m in W6 was chosen to conduct further field testing. A tubing screen was designed to be placed at a depth between 32 and 33.5 m in well W6. A sand pack was placed around the screened section and a 50-cm thick bentonite plug was used for sealing the annular space above and below the sand pack to prevent groundwater from entering through nearby fractures. (Fig. S3 of the ESM). After the sealing of W6, a third hydraulic test was performed to re-examine the hydraulic connectivity between wells W4 and W6 (Fig. S1c of the ESM). The results showed that a hydraulic connection between W4 and W6 was still present through the 1.5-m screened section in W6.

Tracer tests

Tracer tests were designed to investigate fracture flow paths between the wells, particularly the position of incoming tracers in the observation well. W6 was designated the injection well and W4 the observation well. Before the tracer tests, well W4 was pumped to reduce fine particles in the borehole and rock fractures. When an electrical conductivity sensor was placed in W6, the measured depth of the bottom hole was 32.5 m, indicating the well W6 was actually screened from 31 to 32.5 m, instead of the designed depth of 32–33.5 m. In W6, the transmissivity at the actual screened depth was smaller than that at the designed depth (Fig. S3 of the ESM); however, the third hydraulic test indicated that W4 and W6 were still connected despite misplacing the screened section in W6; thus, the two wells could be used for the saline and nZVI tracer tests.

In conformity with the measured depth of permeable zones by the flowmeter, an electrical conductivity sensor was placed at the depth of 29 m in W6, and two other sensors were installed respectively at the depths of 24 and 28.5 m in W4. Before the nZVI tracer test, a magnet array was placed between the depths of 23 and 43 m to detect where and how nZVI particles were attracted in W4. A forced gradient with a divergent flow field was used to conduct the tracer tests. A schematic diagram of the tracer test setting is shown in Fig. 3.

Fig. 3
figure 3

Schematic diagram of the setting for the two tracer tests, including the saline tracer test and nZVI tracer test, in the field. Only in W4 (the observation well) was a 20-m magnet array installed during the nZVI tracer test

Saline tracer test

A saline solution was prepared by dissolving 1 kg of salt (NaCl) in 20 L of water. The saline solution and water from a distant well were mixed and injected into W6 at a rate of 40 ml/s for about 9 min. This was followed immediately by continuously injecting ambient water at a constant rate to maintain a constant head with an overflow condition throughout the test.

Before the injection, the background electrical conductivity in W6 was 650 μS/cm (Fig. 4a); however, 5 min into injection, the electrical conductivity at 29 m began to increase sharply, rising up to 60,190 μS/cm at 6 min. Thereafter it was steady for about a minute and then dropped precipitously to 1,450 μS/cm at 14 min; the pulse for the rise and fall lasted for approximately 10 min.

Fig. 4
figure 4

Changes in electrical conductivity during the saline tracer test. a Time series of electrical conductivity recorded at the depth of 29 m in injection well W6. b Time series of electrical conductivity recorded at depths of 24 and 28.5 m, respectively, in observation well W4. The horizontal axes are the elapsed time after the saline tracer injection

Electrical conductivity at 24 m in the observation well was about 600–620 μS/cm throughout the test (Fig. 4b). In contrast, electrical conductivity at 28.5 m started to increase 9 min after tracer injection. It peaked at 17,389 μS/cm at 13 min and then declined to 650 μS/cm by the end of tracer test. The duration of the breakthrough curve was approximately 41 min. The dispersion of saline solution was evident even though the horizontal distance was only 2.57 m between the wells. The test results indicated that the arrival of saline tracer in W4 through permeable fractures from W6; however, it was difficult to identify the actual positions of the permeable connected fractures in W4.

nZVI tracer test

Before the nZVI tracer test, 9 L of slurry consisting of approximately 77 g of nZVI particles was synthesized in the laboratory. The nZVI slurry was released into W6 at a rate of 37 ml/s for about 4 min. Then ambient water was injected at a constant rate into the wellhead with an overflow condition to maintain a constant head throughout the test.

Electrical conductivity at 29 m in W6 was around 660 μS/cm before the nZVI slurry was injected (Fig. 5a), but declined to 380 μS/cm in 5 min before abruptly rising to 2,500 μS/cm 7 min after the nZVI slurry had been injected. As the electrical conductivity was 360 μS/cm at the depth of 12 m and 660 μS/cm at the depth of 29 m prior to the test, the initial decrease in electrical conductivity was likely caused by the downward flow of shallow stagnant water in W6. The conductivity decrease was followed by a rapid increase due to passage of the nZVI slurry. After all the nZVI slurry had migrated into the permeable fracture at 10 min, electrical conductivity in the injection well varied between 560 and 610 μS/cm because of the follow-up injection of ambient water.

Fig. 5
figure 5

Changes in electrical conductivity during the nZVI tracer test. a Time series of electrical conductivity recorded at the depth of 29 m in injection well W6. b Time series of electrical conductivity recorded at depths of 24 and 28.5 m, respectively, in observation well W4. The horizontal axes are the elapsed time after the nZVI tracer injection

In W4, electrical conductivity was recorded throughout the tracer test at 24 and 28.5-m depths (Fig. 5b). At 24 m, it was 610–620 μS/cm for the first 98 min after the injection. Subsequently, it slowly decreased and stabilized at 570 μS/cm through the end of the tracer test. This result indicated that the nZVI slurry did not migrate upward to 24 m in the observation well. On the contrary, the electrical conductivity at 28.5 m depth in W4 started to increase 1.7 min after the injection, and reached a small peak of 639 μS/cm at 9 min. The small peak was likely caused by the inflow of formation water or deep stagnant well water (660 μS/cm) in W6. Immediately after, the electrical conductivity declined to 563 μS/cm and then rose sharply 11.5 min after the injection. These conductivity changes were associated with the arrival of well water in W6. The second peak of electrical conductivity was about 985 μS/cm, which was much higher than the ambient electrical conductivity (560–660 μS/cm), indicating the arrival of the nZVI slurry. This was followed by a decrease in electrical conductivity to 483 μS/cm at 21 min. Then the electrical conductivity increased again to the background level and stayed in the range of 560–620 μS/cm until the end of tracer test.

Before the nZVI tracer injection, a neodymium magnet was placed downhole in the wells W4 and W6 and then retrieved to examine the amount of magnetic minerals in the well water. The result did not show any magnetic mineral attracted to the magnet in the two wells. After the completion of the nZVI tracer test, the magnet array assembly was retrieved and examined for the depth and weight of nZVI particles attached to the magnets. The weight of accumulated nZVI particles on the separate magnets ranged from 0.011 to 0.317 g (Fig. 6). The total weight of attached nZVI particles was 5.773 g, which was approximately 7.5% of the injected nZVI particles. The distribution of accumulated nZVI particles on the magnet array ranged between depths of 27 and 43 m. The weight profile of accumulated nZVI particles peaked at 28.6 m, which is consistent with the large changes of electrical conductivity observed there. The laboratory test indicated that the accumulated weight of nZVI particles on a magnet depends on the distance between the flow inlet and the magnet; hence, the weight distribution as a result of the tracer test suggested that the flow inlet of the nZVI slurry was likely to be located between 28 and 29 m in W4. The measured depth of flow inlet agrees with that of a highly permeable zone obtained from heat-pulse flowmeter measurements (Fig. 6).

Fig. 6
figure 6

Weight profile of nZVI particles attracted to the magnet array, section transmissivity from flowmeter measurements, and rock core image in observation well W4. Each point on the plot represents the weight of nZVI particles attracted to a piece of magnet. Each section is 25-cm thick

Flow paths between the wells

According to the flowmeter measurements in W6, the most permeable zone was between 33 and 33.5 m; however, the tubing was actually screened between 31 and 32.5 m in depth (Fig. S3 of the ESM). Although the section transmissivity of the 1.5-m screened section was relatively small, the nZVI tracer test revealed that fractures between 28 and 29 m in W4 and the screened section between 31 and 32.5 m in W6 were hydraulically connected (Fig. 6).

Because the permeable zone between 33 and 33.5 m in W6 was sealed, the nearby less permeable fractures became alternative flow paths. By integrating the flowmeter measurement data with the nZVI tracer test results, the tracer must have migrated through a “subordinate permeable zone” adjacent to the screened section in W6, and then passed through the “dominant permeable zone” into W4 (Fig. 7). The results suggested that the main permeable conduit might have a hydraulic connection with nearby subordinate fractures. When the main permeable conduit was sealed by cement or sediment, these subordinate fractures might become the alternative flow paths. In other words, connecting fractures are not necessarily only one but could easily be a network providing different paths.

Fig. 7
figure 7

Schematic diagram of dominant and subordinate permeable fracture zones connected between wells W6 and W4

Numerical simulation of tracer tests

Simulation of the saline tracer test

A two-dimensional groundwater flow and solute transport model was developed using MODFLOW-2005 (Harbaugh 2005) and MT3DMS (Zheng and Wang 1999). The model was initially used to simulate the saline tracer test (see the ESM for the spatial discretization and boundary conditions of groundwater flow and solute transport model). The recorded saline concentrations during the test were adopted to calibrate the model. The parameters, including the hydraulic conductivities of two permeable zones as well as dispersivities, were specified to produce the best match between the observed and calculated concentrations during the saline tracer test.

The empirical relationship between the electrical conductivity and the concentration of the saline solution was obtained in the laboratory. Hence, fluid conductivities at 29 m in W6 (Fig. 4a) were converted to saline concentrations at the release point (Fig. S4 of the ESM). The breakthrough curve was shown by a plot of normalized concentrations (C/C0) versus elapsed time. C/C0 is the ratio of the measured concentration at the observation point in well W4 to the maximum injected concentration. PEST (Doherty 2015), an automatic software for parameter estimation, was used to calibrate the model. The simulated and the observed breakthrough curves of the saline tracer test match with each other (Fig. 8). The calibrated hydraulic conductivities of dominate and subordinate permeable zones are 1.046 × 10−2 and 1.517 × 10−3 m/s, respectively. The calibrated longitudinal dispersivity is 0.124 m, while the transverse dispersivity is 0.0124 m (see the ESM for the uncertainty and sensitivity analysis of model output). Based on the flowmeter measurement results, the transmissivities of the dominant and subordinate permeable zones in W6 are 1.73 × 10−6 and 2.51 × 10−7 m2/s, respectively. Thus, the estimated effective aperture of the fracture, calculated by the transmissivities of the permeable zones divided by the identified hydraulic conductivities, is about 0.16–0.17 mm.

Fig. 8
figure 8

Comparison of the calculated and observed breakthrough curves at the observation point during the saline tracer test. The breakthrough curve is plotted as normalized concentration (C/C 0 ) of saline solution against elapsed time since the injection. C/C0 is the ratio of the concentration at the depth of 28.5 m in observation well W4 to the maximum concentration in injection well W6

Simulation of the nZVI tracer test

After calibrating the numerical model, the model was used to simulate the nZVI tracer test. All geological parameters were the same in both saline and nZVI tracer tests to maintain the same flow fields. Specified head boundaries were set to the hydraulic heads measured in wells W4 and W6 during the nZVI tracer test. Electrical conductivity is assumed to vary linearly with the concentrations of the nZVI slurry—for comparison, the simulated concentration was converted to electrical conductivity (EC). Both the simulated and observed electrical conductivities were normalized by the maximum initial electrical conductivity (EC0).

Simulated results indicate that the nZVI slurry passed 28.5 m in W4 from 11 to 24 min (Fig. 9a). While the simulated maximum electrical conductivity of the nZVI slurry occurred at 14.9 min, the maximum electrical conductivity in W4 was recorded at 13.7 min (Fig. 9b). The simulated tracer breakthrough curve cannot match with the observed data of the nZVI tracer test. The inconsistency is likely caused by the difference in fluid velocity and dispersivity between the nZVI slurry and the saline solution. The difference in velocity can be attributed to different viscosity, density and interference between the slurry and the solution. The difference in velocity and dispersivity can also be induced by elevated velocity and degraded dispersion coefficient due to larger size of nZVI particles than that of solutes (James and Chrysikopoulos 2003).

Fig. 9
figure 9

Breakthrough curves at the observation point during the nZVI tracer test. a The calculated C/C0 of the nZVI slurry is compared against the observed C/C0 versus elapsed time since the injection. b The calculated EC/EC0 of the nZVI slurry is compared against the observed EC/EC0 versus elapsed time since the injection. EC is the electrical conductivity at the depth of 28.5 m in observation well W4, and EC 0 is the maximum electrical conductivity in injection well W6

Discussion and conclusions

Discussion

By comparing the two breakthrough curves recorded at the depth of 28.5 m in W4 (Figs. 4b and 5b), one can see the nZVI tracer less dispersive than the saline tracer. The variance is attributed to the difference in migration between solute and colloid with solid particles. During the tracer injection, the nZVI slurry is diluted by the well water, reducing the stability of the colloidal system. The nZVI particles tend to form chain-like aggregates that can lead to the formation of micrometer-sized particles (Phenrat et al. 2007). As the aggregates of large size cannot pass through small pores, they tend to migrate through larger pores in the connected fractures. The effective particle velocity is elevated, while the overall particle dispersion is degraded in a fracture (James and Chrysikopoulos 2003); therefore, the pulse change in electrical conductivity caused by the nZVI tracer migration is faster, but less dispersive than that caused by the saline tracer.

Tracer test results indicated that nZVI particles attracted to the magnet array provided a direct evidence of a preferential flow path to the observation well. The weight profile of nZVI particles peaked at 28.6 m in W4 (Fig. 6). As a result of a magnetic attraction force of neodymium magnet, most of nZVI particles of the incoming slurry were attracted to the magnets near the entrance, particularly the segment between 28 and 29 m. A small amount was observed below the segment due to gravity sedimentation. Only a tiny amount was carried upward possibly cause by the increasing hydraulic head in W4 during the injection process. Based on the monitoring data at observation well W4, the well water level increased 1.08 m in 35 min after the injection, and then remained steady at this level till the end of tracer test. Such an increase was expected to induce the upward flow at W4 during the first 35 min. Generally the mass of nZVI particles captured by the magnets decreased with increasing distance from the entrance (Fig. 6), similar to the observations in the laboratory test (Fig. 1b); hence, the mass profile of attracted nZVI particles can be used to locate the position of connected permeable fracture zones.

Some smaller peaks in the weight profile were found below 29 m in depth (Fig. 6). These peaks are attributed to a non-uniform downward migration of the nZVI slurry. In the laboratory test, the nZVI slurry was observed to migrate spirally downward to the bottom in the observation pipe. The nZVI particles would be randomly attracted to the magnets while moving downward in the observation well, resulting in a non-linear decaying weight profile. The smaller peaks are also possibly caused by the inflow of nZVI slurry through less permeable connected fractures.

The total mass of accumulated nZVI particles on the magnet array was 5.773 g. The total mass of injected nZVI particles was 77 g; thus, the mass recovery rate in the nZVI tracer test was approximately 7.5%. In a two-dimensional homogeneous formation, the injected tracer is anticipated to migrate radially from an injection well. The distance between the injection well and the observation well is 2.57 m. As the circumference of the divergent flow is 16.14 m and the diameter of the observation well is 10.16 cm, the theoretical mass recovery rate would only be 0.63%. Clearly, the actual mass recovery from the test is more than ten times larger than the theoretical recovery. Such a contrast suggests that transport through the permeable fracture zones is controlled by strong heterogeneity or channelized flow patterns in fractures. The outflow of injected nZVI particles through permeable fractures is largely confined to limited routes, including the one between the injection and observation wells.

As nZVI particles are non-conservative tracer, they may react with the ambient groundwater during the transport process, leading to the mass loss of nano-iron particles. The most important concern is the oxidation of nZVI particles. As the laboratory flow system was carried out in an aerobic environment, most nZVI particles formed chain-like micrometer-sized clusters and remained as zero-valent irons even 6 months after. In the field, the nZVI tracer test was conducted in approximately 5 h, and thus the mass loss of nZVI particles due to the chemical reaction is not a major concern in this study.

The clogging of nZVI particles in rock fractures can be influenced by mechanical entrapment, including attachment, filtration and straining. The dominant retention mechanism may vary with the specific discharge in a fracture (Crane and Moore 1984; Rodrigues et al. 2013). Generally smaller specific discharges (slow flow velocities) result in smaller shear forces, thereby leading to attachment. In the field test of this study, the specific discharge is large due to the injection, and thus the attachment of nZVI particles is relatively small; however, filtration and straining in the fracture may cause clogging of fractures.

Compared with other investigation approaches in fractured rock, the nZVI tracer test did provide more direct and quantitative information such as the maximum attracted mass to the magnets, for delineating the position of tracer inlet (connecting fracture) in the observation well. The position is consistent with the result of saline tracer test and the heat-pulse flowmeter measurements. However, the density effect, clogging of fractures and chemical reactions of nZVI particles may involve in the transport processes, leading to the uncertainty in the delineation of tracer inlet and limiting the application of using nZVI tracers. Further experiments are needed to examine the application and limitation of the nZVI tracer test.

Conclusions

A novel approach of an nZVI tracer test was developed to characterize the preferential flow paths between a screened well and an open hole. By using a magnet array assembly, the distribution of absorbed nZVI particles can be used to locate the depth of incoming tracer in the observation well, providing quantitative approach for delineating connecting fractures. Although the most permeable zone in the injection well was sealed due to misplacing the screened section, the results of both the nZVI tracer test and the saline tracer test revealed that the main permeable conduit might have a hydraulic connection through other nearby subordinate fractures. In other words, once part of the main permeable conduit is sealed by cement or sediments, these subordinate fractures might become the alternative flow paths. This phenomenon was an interesting finding in addition to the delineation of connected fractures. The mass recovery rate of nZVI particles was successfully enhanced by hydraulically isolating a permeable segment in the injection well; however, the actual recovery rate was much higher than the well-dispersed theoretical recovery rate, suggesting the presence of strong heterogeneity or channelized flow patterns in rock fractures. This study has demonstrated that an nZVI tracer test could be a promising approach for characterizing fracture flow paths.