Abstract
Background
Mesh fixation using sealants is becoming increasingly popular in hernia surgery. Fibrin sealant is an atraumatic alternative to suture or stapler fixation and is currently the most frequently used sealant. There are currently no biomechanical data available for evaluation of the quality of adhesion achieved with fibrin sealant during Lichtenstein hernia repair.
Methods
Five different suture and sealant techniques were evaluated and compared during simulated Lichtenstein hernia repair in an established, standardised biomechanical model for abdominal wall hernias.
Results
Significantly greater stability was achieved with fibrin sealant fixation of meshes than with point-by-point suture fixation. Fibrin adhesion protected meshes from dislocation at least as well as suture fixation with additional running-suture closure of the hernia orifice. Fibrin mesh fixation combined with additional support from running-suture hernia closure was significantly (P ≤ 0.002) superior to all other methods.
Conclusions
On the basis of these favourable biomechanical properties, mesh fixation using fibrin sealant can be recommended for use in onlay repair of transinguinal hernias.
Similar content being viewed by others
References
Bay-Nielsen M, Perkins FM, Kehlet H, The Danish Hernia Database (2001) Pain and functional impairment one year after inguinal herniorrhapy: a nationwide questionnaire study. Ann Surg 223:1–7
Aasvang E, Kehlet H (2005) Surgical management of chronic pain after inguinal hernia repair. Br J Surg 92:795–801
Courtney CA, Duffy K, Serpell MG, O’Dwyer PJ (2002) Outcome of patients with severe chronic pain following repair of groin hernia. Br J Surg 89:1310–1314
Callesen T, Bech K, Kehlet H (1999) Prospective study of chronic pain after hernia repair. Br J Surg 86:1528–1531
Lau H (2005) Fibrin sealant versus mechanical stapling for mesh fixation during endoscopic extraperitoneal inguinal hernioplasty: a randomized prospective trial. Ann Surg 242:670–675
Topart P, Vandenbroucke F, Lozac’h P (2005) Tisseel vs tack staples as mesh fixation in totally extraperitoneal laparoscopic repair of groin hernias. Surg Endosc 19:724–727
Schwab R, Willms A, Kröger A, Becker HP (2006) Less chronic pain following mesh fixation using fibrin sealant in TEP inguinal hernia repair. Hernia 10:272–277
Canonico S, Santoriello A, Campitiello F, Fattopace A, Della Corte A, Sordelli I, Benevento R (2005) Mesh fixation with human fibrin glue (Tissucol) in open tension-free inguinal hernia repair: a preliminary report. Hernia 9:330–333
Benizri EI, Rahili A, Avallone S, Balestro JC, Cai J, Benchimol D (2006) Open inguinal hernia repair by plug and patch: the value of fibrin sealant fixation. Hernia 10:389–394
Hidalgo M, Castillo MJ, Eymar JL, Hidalgo A (2005) Lichtenstein inguinal hernioplasty: sutures versus glue. Hernia 9:242–244
Junge K, Klinge U, Prescher A, Giboni P, Niewiera M, Schumpelick V (2001) Elasticity of the anterior abdominal wall and impact for reparation of incisional hernias using mesh implants. Hernia 5:113–118
Amid PK (2004) Lichtenstein tension-free hernioplasty: Its inception, evolution, and principles. Hernia 8:1–7
Amid PK (2003) The Lichtenstein repair in 2002: an overview of causes of recurrence after Lichtenstein tension-free hernioplasty. Hernia 7:13–16
Schwab R, Conze J, Willms A, Klinge U, Becker HP, Schumpelick V (2006) Management of recurrent inguinal hernia after previous mesh repair: a challenge. Chirurg 77:523–530
Brockman JB, Patterson NW, Richardson WS (2004) Burst strength of laparoscopic and open hernia repair. Surg Endosc 18:536–539
Horgan LF, Shelton JC, O’Riordan DC, Moore DP, Winslet MC, Davidson BR (1996) Strengths and weaknesses of laparoscopic and open mesh inguinal hernia repair: a randomized controlled experimental study. Br J Surg 83:1463–1467
Helbling C, Schlumpf R (2003) Sutureless Lichtenstein: first results of a prospective randomised clinical trial. Hernia 7:80–84
Novik B, Hagdorn S, Mörk UB, Dahlin K, Skullmann S, Dahlenbäck J (2006) Fibrin glue for securing the mesh in laparoscopic totally extraperitoneal inguinal hernia repair: a study with a 40-month prospective follow-up period. Surg Endosc 20:462–467
Montanaro L, Arciola CR, Cenni E, Ciapetti G, Savioli F, Filippini F, Barsanti LA (2001) Cytotoxicity, blood compatibility and antimicrobial activity of two cyanoacrylate glues for surgical use. Biomaterials 22:59–66
Katkhouda N, Mavor E, Friedlander MH, Mason RJ, Kiyabu M, Grant SW, Achanta K, Kirkman EL, Narayanan K, Essani R (2001) Use of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repair. Ann Surg 233:18–25
Chevrel JP, Rath AM (1997) The use of fibrin glues in the surgical treatment of incisional hernias. Hernia 1:9–14
Zieren J, Castenholz E, Jacobi CA, Zieren HU, Müller J (1999) Is mesh fixation in abdominal hernia necessary? Langenbecks Arch Surg 384:71–75
Petter-Puchner AH, Fortelny R, Mittermayr R, Öhlinger W, Redl H (2005) Fibrin sealing versus stapling of hernia meshes in an onlay model in the rat. Hernia 9:322–329
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Schwab, R., Schumacher, O., Junge, K. et al. Fibrin sealant for mesh fixation in Lichtenstein repair: biomechanical analysis of different techniques. Hernia 11, 139–145 (2007). https://doi.org/10.1007/s10029-007-0195-6
Received:
Accepted:
Published: