Abstract
Purpose
The overall incidence of periprosthetic femoral fractures (PPF) is between 0.1 and 6 % of all total hip arthroplasties. Locking compression plates (LCP) have been used for the treatment of Vancouver B1 PPFs with variable results. The aim of this study is to examine the literature on locking plate failure rates, mode and reasons for failure.
Methodology
A literature search was conducted for studies reporting the management of PPF of the femur with LCP fixation. The primary medical search engines used for the study were Ovid MEDLINE and EMBASE databases up to August 2012.
Results
Twelve studies were identified, reporting overall union rates of 91 % in 135 fractures. Only 7 (5 %) fractures required revision surgery due to plate fracture (5) or pull out (2). Important trends in plate complications included: stress riser at the end of the plate, stress concentration in the fracture area due to rigid fixation, early loading and absence of cortical strut grafting for biological support when needed.
Conclusion
LCP has been used successfully in the management of Vancouver B1 PPF. However, potential areas of improvement include, leaving the fracture site free of locking screws, therefore, not disturbing the soft tissue envelope around the fracture and also reducing plate stiffness. Adding cortical strut allografts to improve stability and bone quality, if needed, may also improve outcome. Limitations in the use of strut grafts or transverse fractures below the tip of the stem that cannot be controlled with single or double plating may require long stem revision to achieve axial stability.
Similar content being viewed by others
References
Tsiridis E, Pavlou G, Venkatesh R, Bobak P, Gie G. Periprosthetic femoral fractures around hip arthroplasty: current concepts in their management. Hip Int. 2009;19(2):75–86.
Kingdom, N.J.R.U., 2009/2010.
Berry DJ. Epidemiology: hip and knee. Orthop Clin North Am. 1999;30(2):183–90.
Duncan CP, Masri BA. Fractures of the femur after hip replacement. Instr Course Lect. 1995;44:293–304.
Gautier E, Sommer C. Guidelines for the clinical application of the LCP. Injury. 2003;34(Suppl 2):B63–76.
Bottlang M, Doornink J, Fitzpatrick DC, Madey SM. Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength. J Bone Joint Surg Am. 2009;91(8):1985–94.
Moazen M, Jones AC, Jin Z, Wilcox RK, Tsiridis E. Periprosthetic fracture fixation of the femur following total hip arthroplasty: a review of biomechanical testing. Clin Biomech (Bristol, Avon). 2011;26(1):13–22.
Khalid M, Theivendran K, Cheema M, Rajaratnam V, Deshmukh SC. Biomechanical comparison of pull-out force of unicortical versus bicortical screws in proximal phalanges of the hand: a human cadaveric study. Clin Biomech (Bristol, Avon). 2008;23(9):1136–40.
Chakravarthy J, Bansal R, Cooper J. Locking plate osteosynthesis for Vancouver Type B1 and Type C periprosthetic fractures of femur: a report on 12 patients. Injury. 2007;38(6):725–33.
Anakwe RE, Aitken SA, Khan LA. Osteoporotic periprosthetic fractures of the femur in elderly patients: outcome after fixation with the LISS plate. Injury. 2008;39(10):1191–7.
Bryant GK, Morshed S, Agel J, Henley MB, Barei DP, Taitsman LA. Isolated locked compression plating for Vancouver Type B1 periprosthetic femoral fractures. Injury. 2009;40(11):1180–6.
Buttaro MA, Farfalli G, Paredes Núñez M, Comba F, Piccaluga F. Locking compression plate fixation of Vancouver type-B1 periprosthetic femoral fractures. J Bone Joint Surg Am. 2007;89(9):1964–9.
Ebraheim NA, Gomez C, Ramineni SK, Liu J. Fixation of periprosthetic femoral shaft fractures adjacent to a well-fixed femoral stem with reversed distal femoral locking plate. J Trauma. 2009;66(4):1152–7.
Kaab MJ, Stöckle U, Schütz M, Stefansky J, Perka C, Haas NP. Stabilisation of periprosthetic fractures with angular stable internal fixation: a report of 13 cases. Arch Orthop Trauma Surg. 2006;126(2):105–10.
Kobbe P, Klemm R, Reilmann H, Hockertz TJ. Less invasive stabilisation system (LISS) for the treatment of periprosthetic femoral fractures: a 3-year follow-up. Injury. 2008;39(4):472–9.
Kumar V, Kanabar P, Owen PJ, Rushton N. Less invasive stabilization system for the management of periprosthetic femoral fractures around hip arthroplasty. J Arthroplast. 2008;23(3):446–50.
O’Toole RV, Kanabar P, Owen PJ, Rushton N. Low complication rate of LISS for femur fractures adjacent to stable hip or knee arthroplasty. Clin Orthop Relat Res. 2006;450:203–10.
Ricci WM, Bolhofner BR, Loftus T, Cox C, Mitchell S, Borrelli J Jr. Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant. Surg Technique. J Bone Joint Surg Am. 2006;88 Suppl 1 Pt 2:275–82.
Schutz M, Krettek C, Höntzsch D, Regazzoni P, Ganz R, Haas N. Minimally invasive fracture stabilization of distal femoral fractures with the LISS: a prospective multicenter study. Results of a clinical study with special emphasis on difficult cases. Injury. 2001;32 Suppl 3:SC48–54.
Wood GC, Naudie DR, McAuley J, McCalden RW. Locking compression plates for the treatment of periprosthetic femoral fractures around well-fixed total hip and knee implants. J Arthroplast. 2011;26(6):886–92. doi:10.1016/j.arth.2010.07.002.
Xue H, Tu Y, Cai M, Yang A. Locking compression plate and cerclage band for type b1 periprosthetic femoral fractures preliminary results at average 30-month follow-up. J Arthroplast. 2011;26(3):467–71.e1. doi:10.1016/j.arth.2010.03.031.
Pavlou G, Panteliadis P, Macdonald D, Timperley JA, Gie G, Bancroft G, Tsiridis E. A review of 202 periprosthetic fractures—stem revision and allograft improves outcome for type B fractures. Hip Int. 2011;21(1):21–9.
Lujan TJ, Henderson CE, Madey SM, Fitzpatrick DC, Marsh JL, Bottlang M. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation. J Orthop Trauma. 2010;24(3):156–62.
Perren SM. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br. 2002;84(8):1093–110.
Stoffel K, Dieter U, Stachowiak G, Gächter A, Kuster MS. Biomechanical testing of the LCP—how can stability in locked internal fixators be controlled? Injury. 2003;34(Suppl 2):B11–9.
Ahmad M, Nanda R, Bajwa AS, Candal-Couto J, Green S, Hui AC. Biomechanical testing of the locking compression plate: when does the distance between bone and implant significantly reduce construct stability? Injury. 2007;38(3):358–64.
Bellapianta J, Dow K, Pallotta NA, Hospodar PP, Uhl RL, Ledet EH. Threaded screw head inserts improve locking plate biomechanical properties. J Orthop Trauma. 2011;25(2):65–71.
Uhthoff HK, Poitras P, Backman DS. Internal plate fixation of fractures: short history and recent developments. J Orthop Sci. 2006;11(2):118–26.
Haddad FS, Garbuz DS, Masri BA. Duncan CP. Structural proximal femoral allografts for failed total hip replacements: a minimum review of five years. J Bone Joint Surg Br. 2000;82(6):830–6.
Noordeen MH, Lavy CB, Shergill NS, Tuite JD, Jackson AM. Cyclical micromovement and fracture healing. J Bone Joint Surg Br. 1995;77(4):645–8.
Conflict of interest
The authors declare that they have no conflict of interest.
Author information
Authors and Affiliations
Corresponding author
About this article
Cite this article
Graham, S.M., Moazen, M., Leonidou, A. et al. Locking plate fixation for Vancouver B1 periprosthetic femoral fractures: a critical analysis of 135 cases. J Orthop Sci 18, 426–436 (2013). https://doi.org/10.1007/s00776-013-0359-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00776-013-0359-4