Abstract
The proficiency-testing scheme (CNCA-07-06) concerning lead and cadmium determination extracted from glazed ceramic surfaces involved 43 Chinese laboratories as participants, and has been well implemented. All the test materials passed the statistical homogeneity tests, and were deemed suitable for distribution. Reference values were determined from the obtained results and the performance of participants was based on z-scores. As a result, the majority of participants obtained satisfactory z-scores and laboratories that need to revise their procedures were singled out. Overall, about 8.5% of all results submitted in this PT round were unsatisfactory in terms of z-scores (22 out of 258 total data sets submitted), while the percentage of doubtful z-scores was 4.6% (12 out of 258 total data sets). Besides, the factors that might be associated with unsatisfactory results were also evaluated and suggestions were made to help improve the performance of laboratories in this PT.
References
Goyer RA, Clarkson TW (2001) In: Amdur MO, Doull J, Klaassen CD (eds) The basic science of poisons. McGraw-Hill Press, USA, pp 623–680
Haider S, Naithani V, Barthwal J, Kakkar P (2004) Bull Environ Contam Toxicol 72:119–127
Ikem A, Egiebor NO (2005) J Food Comp Anal 18:771–787
ASTM (1973) Standard test method for lead and cadmium extracted from glazed ceramic surface. Method C 738
Code of Federal Regulations (1994) Toxic elements in foods and tableware and cookware. 21CFR 109.16
Lovett RA (1996) Proposition 65 poses challenges to analytical chemists. Prop 65 News 1996:1–4. Available http://www.prop65news.com/pubs/p65 news/issues/9603/96-0312.html
Lenyuva HZ, Gilbert J (2006) Trend Anal Chem 25:554–562
Quevauviller Ph (1995) Quality assurance in environmental monitoring: sampling and sample pre-treatment. VCH, Weinheim, Germany, pp 306–322
Heyden YV, Smeyers-Verbeke J (2007) J Chromatogr A 1158:158–167
Chinese Standard (1995) GB/T 3532: the quality of domestic porcelain, China
ASTM (1988) Standard test method for lead and cadmium extracted from the lip and rim area of glass tumblers externally decorated with ceramic glass enamels. Method C 927
Analytical Methods Committee (1989) Analyst 14:1693–1697
Analytical Methods Committee (2001) Robust statistics: a method of coping with outliers, Technical Brief No 6, http://www.rsc.org/pdf/amc/brief6.pdf
Thompson M (2000) Analyst 125:385–386
Lawn RE, Thompson M, Walker RF (1997) Proficiency testing in analytical chemistry. Royal Society of Chemistry, Cambridge
Thompson M, Potts P, Webb P, Kane J (1997) Analyst 122:1249–1254
Fearn T, Thompson M (2001) Analyst 126:1414–1417
Lamberty A, Schimmel H, Pauwels J (1998) Fresenius J Anal Chem 360:359–361
Van der Veen AMH, Linsinger TPJ, Schimmel H, Lamberty A, Pauwels J (2001) Accred Qual Assur 6:257–263
Bennet CA, Franklin NL (1967) Statistical analysis in chemistry and the chemical industry, 5th edn. Wiley, New York
International Organization for Standardization (2005) ISO 13528:2005, Statistical methods for use in proficiency testing by interlaboratory comparisons, ISO, Geneva, Switzerland (http://www.iso.org)
Ricci M, Bercaru O, Morabito R, Brunori C, Ipolyi I, Pellegrino C, Sahuquillo A, Ulberth F (2007) Trends Anal Chem 26:818–827
Acknowledgment
The authors would like to express their gratitude to the CNAS (China National Accreditation Service for Conformity Assessment).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Tao, L., Xiang, H., Xu, H. et al. Application of the FAPAS protocol to a proficiency testing on Pb and Cd extracted from glazed ceramic. Accred Qual Assur 15, 155–162 (2010). https://doi.org/10.1007/s00769-009-0609-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00769-009-0609-5