Estimating the decision limit and the detection capability using matrix-matched calibration data

  • Practitioner's Report
  • Published:
Accreditation and Quality Assurance Aims and scope Submit manuscript

Abstract

Matrix-matched calibration allows to quantify accurately without the necessity of correcting results for the bias error caused by matrix effects. In this work, an approach to estimate the decision limit CCα and the detection capability CCβ using matrix-matched calibration data series that were obtained at different times and under different conditions is described. The basic idea underlying the approach is to consider the set of the calibration submodels to be an ensemble of equally probable events. By way of illustration, the methodology is applied to a data set acquired within a validation study of an LC–MS assay for the determination of the aminoglycoside antibiotic dihydrostreptomycin in kidney.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

References

  1. Council Directive of 29 April 1996 on measures to monitor substances and residues thereof in live animals and animal products and repealing Directives 85/358/EEC and 86/469/EEC and Decisions 89/187/EEC and 91/664/EEC (96/23/EC), Off J Eur Commun L 125 (1996) 10

    Google Scholar 

  2. Commission Decision of 12 August 2002 implementing Council Directive 96/23/EC concerning the performance of analytical methods and the interpretation of results (2002/657/EC), Off J Eur Commun L 221 (2002) 8-36

    Google Scholar 

  3. Jülicher B, Gowik P, Uhlig S (1998) Analyst 123:173–179

    Article  Google Scholar 

  4. Jülicher B, Gowik P, Uhlig S (1998) Analyst 124:537–545

    Article  Google Scholar 

  5. Antignac JP, Le Bizec F, Andre F (2003) Anal Chim Acta 483:325–334

    Article  CAS  Google Scholar 

  6. Van Loco J, Beernaert H (2003) Proceedings of Euro Food Chem XII 1:91–94

    Google Scholar 

  7. Steliopoulos P, Stickel S, Haas H, Kranz S (2006) Anal Chim Acta 572:121–124

    Article  CAS  Google Scholar 

  8. Verdon E, Hurtaud-Pessel D, Sanders P (2006) Accred Qual Assur 11:58–62

    Article  CAS  Google Scholar 

  9. Tellinghuisen J (2000) Fresenius J Anal Chem 368:585–588

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Panagiotis Steliopoulos.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Steliopoulos, P. Estimating the decision limit and the detection capability using matrix-matched calibration data. Accred Qual Assur 15, 105–109 (2010). https://doi.org/10.1007/s00769-009-0564-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00769-009-0564-1

Keywords

Navigation