Abstract
This work describes a simple, fast (frequency of 170 injections h−1), and low-cost method for the simultaneous determination of two antioxidants, sinapic acid and tyrosol, using multiple-pulse amperometric detection at a glassy carbon electrode incorporated in a flow-injection analysis cell. A sequence of potential pulses was selected to detect sinapic acid and tyrosol separately in the course of a single injection step. During the characterization of electrochemical detection, conditions for the determination of the two antioxidants (such as the injected volume and the flow rate) were studied and the analytical figures of merit were calculated. The repeatability (expressed as %) RSD was < 4.0% (n = 10) and excellent linearity was obtained across two concentration ranges from 1.0 to 100 μM; the limits of detection of sinapic acid and tyrosol were around 1.0 μM.
Graphical abstract
Similar content being viewed by others
References
Charrouf Z, Guillaume D (2007) Am J Food Technol 2:679
Anthony NR, Samuel SM (2008) Research topics in agricultural and applied economics, 1st edn. Sharjah, United Arab Emirates
Lucas R, Comelles F, Alcantara D, Maldonado OS, Curcuroze M, Parra JL, Morales JC (2010) J Agric Food Chem 58:8021
Giovannini C, Straface E, Modesti D, Coni E, Cantafora A, Vincenzi MD, Malorni W, Masella R (1999) J Nutr 129:1269
Miró-Casas E, Covas M-I, Fitó M, Farré-Albadalejo M, Marrugat J, Torre R (1999) Eur J Clin Nutr 57:186
Sousa WR, da Rocha C, Cardoso CL, Silva DHS, Zanoni MVB (2004) Food Compos Anal 17:619
Enache TA, Amine A, Brett CMA, Oliveira-Brett AM (2013) Talanta 105:179
Blekas G, Tsimidou M (2005) Curr Top Nutraceutical Res 3:125
Blekas G, Vassilakis C, Harizanis C, Tsimidou M, Boskou DG (2002) J Agric Food Chem 50:3688
Andjelkovic M, Van Camp J, Trawka A, Verhé R (2010) Eur J Lipid Sci Technol 112:208
Bebeselea A, Manea F, Burtica G, Nagy L, Nagy G (2010) Talanta 80:1068
Gimenes DT, Cunha RR, Carvalho Ribeiro MM, Pereira PF, Muñoz RAA, Richter EM (2013) Talanta 116:1026
Bavol D, Economou A, Zima J, Barek J, Dejmkova H (2018) Talanta 178:231
Tormin TF, Cunha RR, Richter EM, Muñoz RAA (2012) Talanta 99:527
Surareungchai W, Deepunya W, Tasakorn P (2001) Anal Chim Acta 448:215
Gimenes DT, dos Santos WTP, Tormin TF, Muñoz RAA, Richter EM (2010) Electroanalysis 22:74
Silva WC, Pereira PF, Marra MC, Gimenes DT, Cunha RR, da Silva RAB, Muñoz RAA, Richter EM (2011) Electroanalysis 23:2764
de Miranda JAT, Cunha RR, Gimenes DT, Muñoz RAA, Richter EM (2012) Quim Nova 35:1459
Medeiros RA, Lourenção BC, Rocha-Filho RC, Fatibello-Filho O (2010) Anal Chem 82:8658
Medeiros RA, Lourenção BC, Rocha-Filho RC, Fatibello-Filho O (2012) Talanta 99:883
Gimenes DT, dos Santos WTP, Muñoz RAA, Richter EM (2010) Electrochem Commun 12:216
Johnson DC, LaCourse WR (1990) Anal Chem 62:589
Johnson DC, Dobberpuhl D, Roberts R, Vandeberg P (1993) J Chromatogr 640:79
Zima J, Dejmkova H, Barek J (2007) Electroanalysis 19:185
Miller JN, Miller JC (2005) Chemometrics for analytical chemistry, 5th edn. Pearson Education, Harlow
Acknowledgements
Financial support of the Czech Science Foundation (Project P206/12/G151) is acknowledged and Erasmus programme.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Bavol, D., Economou, A., Zima, J. et al. Simultaneous determination of sinapic acid and tyrosol by flow-injection analysis with multiple-pulse amperometric detection. Monatsh Chem 149, 1679–1684 (2018). https://doi.org/10.1007/s00706-018-2189-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00706-018-2189-8