Skip to main content
Log in

A pulled sutures technique for bony Bankart lesion

  • Technical Note
  • Published:
European Journal of Orthopaedic Surgery & Traumatology Aims and scope Submit manuscript

Abstract

In an attempt to present a new surgical technique for arthroscopic bony Bankart fixation, the authors developed the pulled sutures technique. In executing the new method, the authors first passed several non-absorbable sutures through labroligamentous tissue with displaced articular fragment by mimicking transglenoid suture technique. Aimed at achieving a safe and stable fixation, using a knotless anchor rather than transglenoid suture, was deployed. Overall, this pulled sutures technique was shown to be effective with the result of direct reduction, stable, and safe fixation for bony Bankart’s lesion.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Porcellini G, Campi F, Paladini P (2002) Arthroscopic approach to acute bony Bankart lesion. Arthroscopy 18(7):764–769

    Article  PubMed  Google Scholar 

  2. Rowe CR, Zarins B (1981) Recurrent transient subluxation of the shoulder. J Bone Joint Surg Am 63(6):863–872

    CAS  PubMed  Google Scholar 

  3. Bigliani LU, Newton PM, Steinmann SP, Connor PM, McLlveen SJ (1998) Glenoid rim lesions associated with recurrent anterior dislocation of the shoulder. Am J Sports Med 26(1):41–45

    CAS  PubMed  Google Scholar 

  4. Burkhart SS, De Beer JF (2000) Traumatic glenohumeral bone defects and their relationship to failure of arthroscopic Bankart repairs: significance of the inverted-pear glenoid and the humeral engaging hill-sachs lesion. Arthroscopy 16(7):677–694

    Article  CAS  PubMed  Google Scholar 

  5. Itoi E, Lee SB, Berglund LJ, Berge LL, An KN (2000) The effect of a glenoid defect on anteroinferior stability of the shoulder after Bankart repair: a cadaveric study. J Bone Joint Surg Am 82(1):35–46

    CAS  PubMed  Google Scholar 

  6. Sugaya H, Kon Y, Tsuchiya A (2005) Arthroscopic repair of glenoid fractures using suture anchors. Arthroscopy 21(5):635. doi:10.1016/j.arthro.2005.02.006

    Article  PubMed  Google Scholar 

  7. Cameron SE (1998) Arthroscopic reduction and internal fixation of an anterior glenoid fracture. Arthroscopy 14(7):743–746

    Article  CAS  PubMed  Google Scholar 

  8. Porcellini G, Paladini P, Campi F, Paganelli M (2007) Long-term outcome of acute versus chronic bony Bankart lesions managed arthroscopically. Am J Sports Med 35(12):2067–2072. doi:10.1177/0363546507305011

    Article  PubMed  Google Scholar 

  9. Sugaya H, Moriishi J, Kanisawa I, Tsuchiya A (2006) Arthroscopic osseous Bankart repair for chronic recurrent traumatic anterior glenohumeral instability. Surgical technique. J Bone Joint Surg Am 88(Suppl 1 Pt 2):159–169. doi:10.2106/JBJS.F.00319

    PubMed  Google Scholar 

  10. Millett PJ, Braun S (2009) The “bony Bankart bridge” procedure: a new arthroscopic technique for reduction and internal fixation of a bony Bankart lesion. Arthroscopy 25(1):102–105. doi:10.1016/j.arthro.2008.07.005

    Article  PubMed  Google Scholar 

  11. Bauer T, Abadie O, Hardy P (2006) Arthroscopic treatment of glenoid fractures. Arthroscopy 22(5):569.e1–569.e6. doi:10.1016/j.arthro.2006.01.003

    Google Scholar 

Download references

Conflict of interest

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Dong-Il Chun.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lee, B.I., Choi, H.S., Min, K.D. et al. A pulled sutures technique for bony Bankart lesion. Eur J Orthop Surg Traumatol 24, 641–645 (2014). https://doi.org/10.1007/s00590-013-1227-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00590-013-1227-9

Keywords

Navigation