Skip to main content

Advertisement

Log in

A comparative study on the accuracy of pedicle screw placement assisted by personalized rapid prototyping template between pre- and post-operation in patients with relatively normal mid-upper thoracic spine

  • Original Article
  • Published:
European Spine Journal Aims and scope Submit manuscript

Abstract

Purpose

The aim of this study was to assess the accuracy of rapid prototyping drill template technique for placing pedicle screws in the mid-upper thoracic vertebrae in clinics.

Methods

151 consecutive patients underwent thoracic instrumentation and fusion for a total of 582 pedicle screws placed in the mid-upper thoracic vertebrae. Using computer software, the authors constructed drill templates that fit onto the posterior elements of the mid-upper thoracic vertebrae with drill guides designed to instrument the pedicles. The start point and three dimensional location of the planned and inserted screws were measured and compared.

Results

Grading of the CT scans revealed 559 (96.1 %) out of 582 screws completely within the desired pedicle. The direction of pedicle violation included 5 medial, 2 airball, and 16 lateral. The paired t test suggested that these results were statistically significant in more than half of the locations (T1-left-TA(P = 0.024), T2-left-SA(P = 0.031), T3-left-SA(P = 0.014), T4-left-TA(P = 0.004), T5-left-TA(P = 0.034), T7-left-TA(P = 0.000). T1-right-TA(P = 0.049), T2-right-TA(P = 0.044), T3-right-TA(P = 0.014), T5-right-TA(P = 0.013)). The paired t-test suggested that these results were statistically significant at several locations (T4-left-Δy(P = 0.041), T5-left-Δx(P = 0.016), T3-right-Δy(P = 0.015)).

Conclusion

Use of a rapid prototyping drill template to assist in the placement of mid and upper thoracic pedicle screws may lead to increased accuracy. This patient specific technology must be combined with an understanding of the patients’ anatomy and carefully secured to the posterior elements intraoperatively to avoid nerve or vascular complications.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Gaines Jr RW (2000) The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 82:1458–1476

    Google Scholar 

  2. Bydon M, Xu R, Amin AG et al (2014) Safety and efficacy of pedicle screw placement using intraoperative computed tomography: consecutive series of 1148 pedicle screws. J Neurosurg Spine 21:320–328

    Article  PubMed  Google Scholar 

  3. Vanek P, Bradac O, Konopkova R et al (2014) Treatment of thoracolumbar trauma by short-segment percutaneous transpedicular screw instrumentation: prospective comparative study with a minimum 2-year follow-up. J Neurosurg Spine 20:150–156

    Article  PubMed  Google Scholar 

  4. Hackenberg L, Link T, Liljenqvist U (2002) Axial and tangential fixation strength of pedicle screws versus hooks in the thoracic spine in relation to bone mineral density. Spine 27:937–942

    Article  PubMed  Google Scholar 

  5. Lee SM, Suk SI, Chung ER (2004) Direct vertebral rotation: a new technique of three-dimensional deformity correction with segmental pedicle screw fixation in adolescent idiopathic scoliosis. Spine 29:343–349

    Article  PubMed  Google Scholar 

  6. Luhmann SJ, Lenk LG, Kim YJ et al (2005) Thoracic adolescent idiopathic scoliosis curves between 70 degrees and 100 degrees: is anterior release necessary? Spine 30:2061–2067

    Article  PubMed  Google Scholar 

  7. Rampersaud YRPJ, Salonen D, Farooq S (2005) Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: a CT analysis. Spine 30(7):E183–E190

    Article  PubMed  Google Scholar 

  8. Vaccaro AR, Rizzolo SJ, Allardyce TJ et al (1995) Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the toracic vertebrae. J Bone Joint Surg Am 77:1193–1199

    CAS  PubMed  Google Scholar 

  9. Guzey FK, Emel E, Hakan Seyithanoglu M et al (2006) Accuracy of pedicle screw placement for upper and middle thoracic pathologies without coronal plane spinal deformity using conventional methods. J Spinal Disord Tech 19:436–441

    Article  PubMed  Google Scholar 

  10. Watanabe K, Yamazaki A, Hirano T et al (2010) Descending aortic injury by a thoracic pedicle screw during posterior reconstructive surgery: a case report. Spine 35:E1064–E1068

    Article  PubMed  Google Scholar 

  11. Ebraheim NA, Tremains M, Xu R et al (2000) Anatomic study of the cervicothoracic spinal nerves and their relation to the pedicles. Am J Orthop 29:779–781

    CAS  PubMed  Google Scholar 

  12. Lee CS, Kim MJ, Ahn YJ et al (2007) Thoracic pedicle screw insertion in scoliosis using posteroanterior C-arm rotation method. J Spinal Disord Tech 20:66–71

    Article  PubMed  Google Scholar 

  13. Cha SH, Kim C, Choi BK et al (2007) C-arm assessment of cervical pedicle screw: screw coaxial fluoroscopy and oblique view. Spine 32:1721–1727

    Article  PubMed  Google Scholar 

  14. Tabaraee E, Gibson AG, Karahalios DG et al (2013) Intraoperative con beam-computed tomography with navigation (O-ARM) versus conventional fluoroscopy (C-ARM): a cadaveric study comparing accuracy, efficiency, and safety for spinal instrumentation. Spine 38:1953–1958

    Article  PubMed  Google Scholar 

  15. Shin MH, Hur JW, Ryu KS et al. (2015) Prospective comparison study between the fluoroscopy guided and navigation coupled with O-arm-guided pedicle screw placement in the thoracic and lumbosacral spines. J Spinal Disord Tech 28:E347–E351

    Article  PubMed  Google Scholar 

  16. Hu Y, Yuan ZS, Kepler CK et al (2014) Deviation analysis of C1-C2 transarticular screw placement assisted by a novel rapid prototyping drill template: a cadaveric study. J Spinal Disord Tech 27:E181–E186

    Article  PubMed  Google Scholar 

  17. Hu Y, Yuan ZS, Spiker WR et al (2013) Deviation analysis of C2 translaminar screw placement assisted by a novel rapid prototyping drill template: a cadaveric study. Eur Spine J 22:2770–2776

    Article  PubMed  PubMed Central  Google Scholar 

  18. Ma T, Xu YQ, Cheng YB et al (2012) A novel computer-assisted drill guide template for thoracic pedicle screw placement: a cadaveric study. Arch Orthop Trauma Surg 132:65–72

    Article  PubMed  Google Scholar 

  19. Merc M, Drstvensek I, Vogrin M, Brajlih T, Recnik G (2013) A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine. Arch Orthop Trauma Surg 133:893–899

    Article  PubMed  Google Scholar 

  20. Panjabi MM, O’Holleran JD, Crisco JJ 3rd et al (1997) Complexity of the thoracic spine pedicle anatomy. Eur Spine J 6:19–24

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  21. Kim YJ, Lenke LG, Bridwell KH et al (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine 29:333–342

    Article  PubMed  Google Scholar 

  22. Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine 15:11–14

    Article  CAS  PubMed  Google Scholar 

  23. Sim E (1993) Location of transpedicular screws for fixation of the lower thoracic and lumbar spine. Computed tomography of 45 fracture cases. Acta Orthop Scand 64:28–32

    Article  CAS  PubMed  Google Scholar 

  24. Laine T, Schlenzka D, Makitalo K, Tallroth K, Nolte LP, Visarius H (1997) Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients. Spine 22:1254–1258

    Article  CAS  PubMed  Google Scholar 

  25. Karapinar L, Erel N, Ozturk H, Altay T, Kaya A (2008) Pedicle screw placement with a free hand technique in thoracolumbar spine: is it safe? J Spinal Disord Tech 21:63–67

    Article  PubMed  Google Scholar 

  26. Modi H, Suh SW, Song HR, Yang JH (2009) Accuracy of thoracic pedicle screw placement in scoliosis using the ideal pedicle entry point during the freehand technique. Int Orthop 33:469–475

    Article  PubMed  PubMed Central  Google Scholar 

  27. Schizas C, Michel J, Kosmopoulos V, Theumann N (2007) Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization. Eur Spine J 16:613–617

    Article  PubMed  PubMed Central  Google Scholar 

  28. Upendra BN, Meena D, Chowdhury B, Ahmad A, Jayaswal A (2008) Outcome-based classification for assessment of thoracic pedicular screw placement. Spine 33:384–390

    Article  PubMed  Google Scholar 

  29. Roy-Camille R, Saillant G, Mazel C (1986) Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates. Orthop Clin North Am 17:147–159

    CAS  PubMed  Google Scholar 

  30. Fennell VS, Palejwala S, Skoch J et al. (2014) Freehand thoracic pedicle screw technique using a uniform entry point and sagittal trajectory for all levels: prelimimary clinical experience. J Neurosurg Spine 21:778–784

    Article  PubMed  Google Scholar 

  31. Elliott MJ, Slakey JB (2007) Thoracic pedicle screw placement: analysis using anatomical landmarks without image guidance. J Pediatr Orthop 27:582–586

    Article  PubMed  Google Scholar 

  32. Pesenti S, Bartoli MA, Blondel B et al (2014) Endovascular aortic injury repair after thoracic pedicle screw placement. Orthop Traumatol Surg Res 100:569–573

    Article  CAS  PubMed  Google Scholar 

  33. Tong X, Gu P, Yu D et al. (2013) An endovascular treatment of a thoracic aortic injury caused by a misplacement pedicle screw: Case report and review of the literature. J Formos Med Assoc 114:464–468

    Article  PubMed  Google Scholar 

  34. Hansen-Algenstaedt N, Chiu CK, Chan CY, Lee CK, Schaefer C, Kwan MK (2015) Accuracy and safety of fluoroscopic guided percutaneous pedicle screws in thoracic and lumbosacral spine: a review of 2000 screws. Spine (Phila Pa 1976) 40:E954–E963

    Article  Google Scholar 

  35. Lamartina C, Cecchinato R, Fekete Z et al. (2015) Pedicle screw placement accuracy in thoracic and lumbar spinal surgery with a patient-matched targeting guide: a cadaveric study. Eur Spine J, Nov; 24 Suppl 7:937–941

  36. Yüksel KZ, Adams MS, Chamberlain RH et al (2007) Pullout resistance of thoracic extrapedicular screws used as a salvage procedure. Spine J 7:286–291

    Article  PubMed  Google Scholar 

  37. Hu Y, Yuan ZS, Kepler CK et al (2014) Deviation analysis of atlantoaxial pedicle screws assisted by a drill template. Orthopedics 37:e420–e427

    Article  PubMed  Google Scholar 

  38. Merc M, Drstvensek I, Vogrin M et al (2014) Error rate of multi-level rapid prototyping trajectories for pedicle screw placement in lumbar and sacral spine. Chin J Traumatol 17:261–266

    PubMed  Google Scholar 

  39. Takemoto M, Fujibayashi S, Ota E, et al (2015) Additive-manufactured patient-specific titanium templates for thoracic pedicle screw placement: novel design with reduced contact area. Eur Spine J. (Epub ahead of print)

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yong Hu.

Ethics declarations

Conflict of interest

We have no potential conflict of interest.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Hu, Y., Yuan, Zs., Spiker, W.R. et al. A comparative study on the accuracy of pedicle screw placement assisted by personalized rapid prototyping template between pre- and post-operation in patients with relatively normal mid-upper thoracic spine. Eur Spine J 25, 1706–1715 (2016). https://doi.org/10.1007/s00586-016-4540-2

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00586-016-4540-2

Keywords

Navigation