Skip to main content
Log in

A study of sacral anthropometry to determine S1 screw placement for spinal lumbosacral fixation in the Korean population

  • Original Article
  • Published:
European Spine Journal Aims and scope Submit manuscript

Abstract

Purpose

  1. 1.

    To investigate the incidence of closed-type PSIS in the Korean population.

  2. 2.

    To categorize the morphological features of Korean sacrum.

  3. 3.

    To measure the safe marginal length and angle for screw fixation considering the PSIS and course of the external iliac vein, using a Korean sacrum model.

Methods

We performed our study in 160 sacra including the pelvic ring obtained from 80 Korean cadavers. The bony measurements were obtained by performing 1-mm computed tomography cuts from the L5 lumbar vertebra to the pelvic ring and excluding other structures. We evaluated the incidence of anatomic variation of the PSIS and measured the safe marginal length and angle for screw fixation considering the PSIS and course of the external iliac vein, using a Korean sacrum model.

Results

Our study showed that the closed type of PSIS is more frequent in males than in females. The optimal angle for screw fixation is 16.91 ± 6.85 (°), while the left side S1 pedicle insertion angle is 16.00 ± 6.20 (°). The average Korean optimal screw length is 58.35 ± 14.90 (cm) for the right side and 55.89 ± 16.16 (cm) for the left side.

Conclusion

With reference to these parameters, the optimal screw length and angle can be chosen and bicortical anteromedial screw fixation can be easily and safely performed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Zindrick MR, Wiltse LL, Widell EH, Thomas JC, Holland WR, Field BT, Spencer CW (1986) A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop Relat Res 203:99–112

    PubMed  Google Scholar 

  2. Kaptanoglu E, Okutan O, Tekdemir I, Beskonakli E, Deda H (2003) Closed posterior superior iliac spine impeding pediculocorporeal S-1 screw insertion. J Neurosurg 99:229–234

    PubMed  Google Scholar 

  3. Kato M, Taneichi H, Suda K (2013) Advantage of pedicle screw placement into the sacral promontory (tricortical purchase) on lumbosacral fixation. J Spinal Disord Tech. doi:10.1097/BSD.0b013e31828ffc70

    Google Scholar 

  4. Carlson GD, Abitbol JJ, Anderson DR, Krag MH, Kostuik JP, Woo SL, Garfin SR (1992) Screw fixation in the human sacrum. An in vitro study of the biomechanics of fixation. Spine (Phila Pa 1976) 17:S196–S203

    Article  CAS  Google Scholar 

  5. Smith SA, Abitbol JJ, Carlson GD, Anderson DR, Taggart KW, Garfin SR (1993) The effects of depth of penetration, screw orientation, and bone density on sacral screw fixation. Spine (Phila Pa 1976) 18:1006–1010

    Article  CAS  Google Scholar 

  6. Yu BS, Zhuang XM, Zheng ZM, Zhang JF, Li ZM, Lu WW (2010) Biomechanical comparison of 4 fixation techniques of sacral pedicle screw in osteoporotic condition. J Spinal Disord Tech 23:404–409. doi:10.1097/BSD.0b013e3181b63f4d

    Article  PubMed  Google Scholar 

  7. Weistroffer JK, Perra JH, Lonstein JE, Schwender JD, Garvey TA, Transfeldt EE, Ogilvie JW, Denis F, Winter RB, Wroblewski JM (2008) Complications in long fusions to the sacrum for adult scoliosis: minimum five-year analysis of fifty. Spine (Phila Pa 1976) 33:1478–1483. doi:10.1097/BRS.0b013e3181753c53

    Article  Google Scholar 

  8. Emami A, Deviren V, Berven S, Smith JA, Hu SS, Bradford DS (2002) Outcome and complications of long fusions to the sacrum in adult spine deformity: Luque–Galveston, combined iliac and sacral screws, and sacral fixation. Spine (Phila Pa 1976) 27:776–786

    Article  Google Scholar 

  9. Sae-Jung S, Khamanarong K, Woraputtaporn W, Amarttayakong P (2014) Awareness of the median sacral artery during lumbosacral spinal surgery: an anatomic cadaveric study of its relationship to the lumbosacral spine. Eur Spine J. doi:10.1007/s00586-014-3641-z

    PubMed  Google Scholar 

  10. Licht NJ, Rowe DE, Ross LM (1992) Pitfalls of pedicle screw fixation in the sacrum. A cadaver model. Spine (Phila Pa 1976) 17:892–896

    Article  CAS  Google Scholar 

  11. Ergur I, Akcali O, Kiray A, Kosay C, Tayefi H (2007) Neurovascular risks of sacral screws with bicortical purchase: an anatomical study. Eur Spine J 16:1519–1523. doi:10.1007/s00586-007-0326-x

    Article  PubMed Central  PubMed  Google Scholar 

  12. Jutte PC, Castelein RM (2002) Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations. Eur Spine J 11:594–598. doi:10.1007/s00586-002-0469-8

    Article  CAS  PubMed  Google Scholar 

  13. Lehman RA Jr, Kuklo TR, Belmont PJ Jr, Andersen RC, Polly DW Jr (2002) Advantage of pedicle screw fixation directed into the apex of the sacral promontory over bicortical fixation: a biomechanical analysis. Spine (Phila Pa 1976) 27:806–811

    Article  Google Scholar 

  14. Luk KD, Chen L, Lu WW (2005) A stronger bicortical sacral pedicle screw fixation through the s1 endplate: an in vitro cyclic loading and pull-out force evaluation. Spine (Phila Pa 1976) 30:525–529

    Article  Google Scholar 

  15. Sabry FF, Xu R, Nadim Y, Ebraheim NA (2001) Bone density of the first sacral vertebra in relation to sacral screw placement: a computed tomography study. Orthopedics 24:475–477

    CAS  PubMed  Google Scholar 

  16. de Peretti F, Argenson C, Bourgeon A, Omar F, Eude P, Aboulker C (1991) Anatomic and experimental basis for the insertion of a screw at the first sacral vertebra. Surg Radiol Anat 13:133–137

    Article  PubMed  Google Scholar 

  17. Mirkovic S, Abitbol JJ, Steinman J, Edwards CC, Schaffler M, Massie J, Garfin SR (1991) Anatomic consideration for sacral screw placement. Spine (Phila Pa 1976) 16:S289–S294

    Article  CAS  Google Scholar 

  18. Zheng Y, Lu WW, Zhu Q, Qin L, Zhong S, Leong JC (2000) Variation in bone mineral density of the sacrum in young adults and its significance for sacral fixation. Spine (Phila Pa 1976) 25:353–357

    Article  CAS  Google Scholar 

  19. Arman C, Naderi S, Kiray A, Aksu FT, Yilmaz HS, Tetik S, Korman E (2009) The human sacrum and safe approaches for screw placement. J Clin Neurosci 16:1046–1049. doi:10.1016/j.jocn.2008.07.081

    Article  PubMed  Google Scholar 

  20. Inoue M, Inoue G, Ozawa T, Miyagi M, Kamoda H, Ishikawa T, Suzuki M, Sakuma Y, Oikawa Y, Yamauchi K, Orita S, Takaso M, Toyone T, Takahashi K, Ohtori S (2013) L5 spinal nerve injury caused by misplacement of outwardly-inserted S1 pedicle screws. Eur Spine J 22(Suppl 3):S461–S465. doi:10.1007/s00586-012-2634-z

    Article  PubMed  Google Scholar 

  21. Xu R, Ebraheim NA, Mohamed A, el-Gamal H, Yeasting RA (1995) Anatomic considerations for dorsal sacral plate-screw fixation. J Spinal Disord 8:352–356

    CAS  PubMed  Google Scholar 

  22. Robertson PA, Plank LD (1999) Pedicle screw placement at the sacrum: anatomical characterization and limitations at S1. J Spinal Disord 12:227–233

    CAS  PubMed  Google Scholar 

  23. Krag MH (1991) Biomechanics of thoracolumbar spinal fixation. A review. Spine (Phila Pa 1976) 16:S84–S99

    Article  CAS  Google Scholar 

  24. Roy-Camille R, Saillant G, Mazel C (1986) Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res 203:7–17

    PubMed  Google Scholar 

  25. Zhu Q, Lu WW, Holmes AD, Zheng Y, Zhong S, Leong JC (2000) The effects of cyclic loading on pull-out strength of sacral screw fixation: an in vitro biomechanical study (Phila Pa 1976). Spine 25:1065–1069

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to In-Soo Oh.

Ethics declarations

Conflict of interest

None.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kim, YY., Ha, KY., Kim, SI. et al. A study of sacral anthropometry to determine S1 screw placement for spinal lumbosacral fixation in the Korean population. Eur Spine J 24, 2525–2529 (2015). https://doi.org/10.1007/s00586-015-4159-8

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00586-015-4159-8

Keywords

Navigation