Dear Editor,

An interesting paper was published in 2015 in the European Spine Journal [1]. We congratulate the authors addressing the important topic of evaluating the differences in the cervical alignment between standing cervical lateral radiograph and whole-spine lateral radiograph with clavicle position.

However, we would like to express our concerns regarding the aforementioned study.

First, when comparing results of measurements performed on standing cervical lateral radiographs versus on whole-spine lateral radiographs the agreement of the two methods rather than the differences between them is tested [2]. Thus, comparing differences in means of the particular parameters by use of the paired t test does not seem to be an appropriate statistical approach [24]. According to the published guidelines other statistical methods should be used [24]. This may be of high importance for the McGregor line angle for which statistical significance was not reached in the study by Park et al. [1].

Second, we think that when comparing measurements based on radiographs performed in different ways testing the intraobserver reproducibility of such measurements would be valuable [2].

Lastly, in the “Materials and methods” section the methodology of intraobserver reliability testing is described with details; however, one important information is missing: it is not specified if all of the parameters were measured by two researchers on radiographs of all of the examined 101 patients or only on some sample of the whole study group. Such an information that is crucial for the statistical power analysis should be specified according to published guidelines of testing the reliability [2].

We believe that using an appropriate and clear methodological approach would emphasize the importance of conclusions of the study by Park et al. [1] that the true cervical sagittal alignment should be evaluated in cervical lateral radiograph with the subject in a neutral relaxed position.