Experimental investigation on performance of disposable micropump with retrofit piezo stack actuator for biomedical application

  • Technical Paper
  • Published:
Microsystem Technologies Aims and scope Submit manuscript

Abstract

Extensive researches are being conducted to develop miniaturized pumping systems to fulfill the need for accurate delivery of fluids at required rates, particularly in the biomedical field. This paper presents the design, fabrication, and testing of novel valveless micropump actuated through an amplified piezo actuator. The proposed model of the micropump pump has the unique feature of a disposable chamber and employs low-cost polymeric materials, conventional molding and machining operations for fabrication. The disposable part of the pump consists of a laser-cut pump chamber with nozzle/diffuser made of Polymethyl methacrylate (PMMA) and conventionally molded silicone rubber diaphragm. The retrofit part includes the amplified piezo actuator and support structures build from PMMA. Systematic characterization of the pump was carried with water and blood mimicking fluid to understand the effect of operating parameters such as driving frequency and actuation voltage on flow rate and back pressure of the micropump. Experimental results show that the proposed design was capable of pumping 3.3–3.4 ml/min of dye solution and 1.7–1.75 ml/min of blood mimicking fluid at a driving frequency of 5 Hz and actuation voltage of 150 V. The corresponding computed volume resolution/stroke of the pump was found to about 5.75 µl and 11.25 µl of blood mimicking fluid and dye solution, respectively. The proposed pump was found to work effectively against a maximum back pressure of 156 Pa with blood mimicking fluid and 250 Pa with the dye solution as the working fluid under the same operating condition of 5 Hz and 150 V.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19

Similar content being viewed by others

References

Download references

Acknowledgements

The authors acknowledge the experimental facility provided by Centre for System Design (CSD): A Centre of excellence at National Institute of Technology Karnataka, Surathkal, India.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S. Mohith.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Mohith, S., Karanth, P. & Kulkarni, S.M. Experimental investigation on performance of disposable micropump with retrofit piezo stack actuator for biomedical application. Microsyst Technol 25, 4741–4752 (2019). https://doi.org/10.1007/s00542-019-04414-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00542-019-04414-2

Navigation