Avoid common mistakes on your manuscript.
To the Editor:
We experienced a case of high brightness artifacts on abdominal ultrasound sonography (US).
A 66-year-old Japanese male was scheduled for a laparoscopic nephrectomy. He receives haemodialysis from when he was 36 years old 3 times a week for chronic renal failure. Hemodialysis-induced hyperphosphatemia had developed and oral treatment with lanthanum carbonate hydrate (LCH) had been given. General anesthesia was induced, and we attempted a transversus abdominis plane (TAP) block. On the US view, we found a high echoic signal in the intestine ( Supplementary material 1). On abdominal computed tomography (CT), high brightness artifacts were also found in the intestine (Supplementary material 2). Thus, we thought these artifacts were caused by a high-contrast substance in the intestine.
After the operation, a nephrologist told us that the origin of the high-density material in the intestine might be LCH.
LCH is a non-aluminum, non-calcium phosphate binder containing lanthanum, which has been available in Japan since 2009. LCH tablets can be visualized clearly on plain X-ray film and CT [1].
It has been reported that diffuse opacities can be visualized in the intestine on plain X-ray films and on CT in patients taking LCH orally [2]. As well as abdominal US, transesophageal echocardiography is affected by LCH [3]. Most such reports have been made by nephrologists and radiologists. Anesthesiologists perform transesophageal echocardiography and abdominal US, and also need to be familiar with the characteristics of LCH.
References
Chung CL, Chiou SY, Li SY, Jian DY, Chen JY. The case: a peritoneal dialysis patient with an unusual abdominal film. Kidney Int. 2007;72:1291–2.
Hiromitsu H, Minoru M, Tetsuro S, Hidenori Y, Tomonari K, Shin-ichiro K. Beamhardening artifacts on computed tomography images caused by lanthanum carbonate hydrate in a patient on dialysis. Jpn J Radiol. 2010;28:322–4.
Pafcugova J, Horackova M, Hraskova M, Forejt J, Szabo M, Padr R. Radio-opaque appearance of lanthanum carbonate in a patient with chronic renal failure. Nephrol Dial Transplant. 2008;23:1776–8.
Conflict of interest
None to report.
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
This article is published under an open access license. Please check the 'Copyright Information' section either on this page or in the PDF for details of this license and what re-use is permitted. If your intended use exceeds what is permitted by the license or if you are unable to locate the licence and re-use information, please contact the Rights and Permissions team.
About this article
Cite this article
Kuroiwa, K.K., Nakazawa, M. & Nishizawa, M. Lanthanum carbonate hydrate causes artifacts on ultrasound. J Anesth 29, 974 (2015). https://doi.org/10.1007/s00540-015-2034-8
Received:
Accepted:
Published:
Issue Date: