Intraductal ultrasonographic assessment of coagulation depth during endoscopic microwave coagulation therapy in a canine model

  • Published:
Journal of Gastroenterology Aims and scope Submit manuscript

Abstract:

In order to examine the feasibility of endoscopic microwave coagulation therapy (MCT) for the treatment of common bile duct cancer in humans, we investigated the safety and effectiveness of endoscopic MCT with the assistance of intraductal ultrasonography (IDUS). We performed MCT in the canine small intestine as a model because of its similarity in size to the obstructed human common bile duct. Multiple coagulation lesions were made in anesthetized dogs, with the endoscope inserted through a jejunostomy. Under condition "A", the tip of the MCT probe was kept in a fixed position in contact with the mucosa of the intestine, and coagulation was performed with an output of 30 or 50 W for 30 or 10 s, respectively. Under condition "B", the tip of the MCT probe was moved along the intestinal mucosa, and coagulation was performed with an output of 50, 40, or 30 W, all for 10 s. After coagulation, a thin-caliber ultrasonic probe was inserted endoscopically for observation of the effects of coagulation. Each coagulation under condition "A" resulted in degeneration of all layers of the intestine. Coagulation under condition "B" resulted in more localized degeneration, extending from the mucosal layer to the proper muscle layer. By comparison with histologic observations, the accuracy of IDUS in assessing depth of degeneration was 87.5%. Endoscopic microwave coagulation was considered safe and effective, and IDUS was able to accurately assess the effects of microwave coagulation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: June 18, 1999 / Accepted: October 22, 1999

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wada, S., Tamada, K., Tomiyama, T. et al. Intraductal ultrasonographic assessment of coagulation depth during endoscopic microwave coagulation therapy in a canine model. J Gastroenterol 35, 284–289 (2000). https://doi.org/10.1007/s005350050347

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s005350050347

Navigation