Abstract
Background
Tumor recurrence after radical resection of hepatic tumors is not uncommon, suggesting that malignant lesions are missed during surgery. Intraoperative navigation using fluorescence guidance is an innovative technique enabling real-time identification of (sub)capsular liver tumors. The objective of the current study was to compare fluorescence imaging (FI) and conventional imaging modalities for laparoscopic detection of both primary and metastatic tumors in the liver.
Methods
Patients undergoing laparoscopic resection of a malignant hepatic tumor were eligible for inclusion. Patients received standard of care, including preoperative CT and/or MRI. In addition, 10 mg indocyanine green was intravenously administered 1 day prior to surgery. After introduction of the laparoscope, inspection, FI, and laparoscopic ultrasonography (LUS) were performed. Histopathological examination of resected suspect tissue was considered the gold standard.
Results
Twenty-two patients suspected of having hepatocellular carcinoma (n = 4), cholangiocarcinoma (n = 2) or liver metastases from colorectal carcinoma (n = 12), uveal melanoma (n = 2), and breast cancer (n = 2) were included. Two patients were excluded because their surgery was unexpectedly postponed several days. Twenty-six malignancies were resected in the remaining 20 patients. Sensitivity for various modalities was 80 % (CT), 84 % (MRI), 62 % (inspection), 86 % (LUS), and 92 % (FI), respectively. Three metastases (12 %) were identified solely by FI. All 26 malignancies could be detected by combining LUS and FI (100 % sensitivity).
Conclusion
This study demonstrates added value of FI during laparoscopic resections of several hepatic tumors. Although larger series will be needed to confirm long-term patient outcome, the technology already aids the surgeon by providing real-time fluorescence guidance.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Major advances have been achieved in the treatment of patients with liver-only metastases and primary liver tumors. Several studies and meta-analyses show improved overall survival after aggressive resection [1–3]. Recurrence-free survival, however, is rather low. Up to 69 % of patients with colorectal liver metastases develop local recurrence or new metastases, with the majority in the first year [4]. Similar rates are reported in patients undergoing resection of hepatocellular carcinoma (HCC) [5]. These numbers are not entirely explained by incomplete resections and support the hypothesis that small malignant lesions are missed during resection.
It is well known that preoperative imaging modalities, including computed tomography (CT) and magnetic resonance imaging (MRI), have relatively low sensitivity for sub-centimeter lesions due to their limited spatial resolution. Moreover, altered body position during surgery and time interval between preoperative imaging and surgery make translation of preoperative images challenging. Extensive intraoperative inspection and palpation of the liver is therefore of vital importance. Palpation, however, is impossible during minimally invasive procedures. Laparoscopic ultrasonography (LUS) can assist in detecting tumors, but acoustic reflection artifacts can obscure tumors in the first millimeters below the liver capsule [6]. In short, surgeons need a highly sensitive, real-time intraoperative imaging modality to identify small superficial tumors in the liver.
Ishizawa et al. [7] reported in 2009 that an intravenous injection of the safe and widely used dye indocyanine green (ICG) causes “bullseyes” of fluorescence to be formed around primary or metastatic tumors in the liver. Defective biliary clearance in the transition area between tumor and normal liver tissue and in primary liver tumors results in ICG retention, which can be visualized using a near-infrared (NIR) fluorescence imaging system. Our group showed that this method of detection is feasible during resection of hepatocellular carcinoma (HCC) and hepatic metastases of uveal melanoma (UMLM) and colorectal cancer (CRLM) [8–10]. The added value of fluorescence imaging during oncological liver surgery is twofold: (1) It can demarcate liver tumors and provide real-time resection margin assessment, and (2) it can identify otherwise undetectable, i.e., occult, (sub)capsular liver tumors. NIR fluorescence imaging can be especially valuable during minimally invasive procedures, because surgeons are deprived of tactile feedback. Based on previous study results, fluorescence imaging is now routinely performed during laparoscopic liver surgery in our hospital if patients provide informed consent. The purpose of the present study was to compare sensitivity and positive predictive values of fluorescence imaging with CT, MRI, visual inspection, and LUS during laparoscopic resection of several tumor types in the liver.
Materials and methods
Patients
The local Medical Ethics Committee and the Departments of Surgery and Anesthesiology approved the implementation of NIR fluorescence imaging during oncologic liver surgery as standard of care. Informed consent from all patients was obtained. ICG (25 mg vials, Pulsion Medical Systems, Munich, Germany) was dissolved in 10 mL sterile water to yield a 2.5 mg/L (3.2 mM) concentration. Subsequently, a bolus of 4 mL containing 10 mg ICG was administered intravenously 24 h prior to surgery. Dose and time of administration were optimized in our previous study [8].
All patients undergoing laparoscopic staging or resection of a liver tumor were eligible for inclusion. Exclusion criteria were eGFR <55, pregnancy, lactation, and an allergy to iodine, shellfish, or ICG. Preoperative imaging was performed using computed tomography (CT) with or without positron emission tomography (PET) and in most cases also using magnetic resonance imaging (MRI), all within 6 weeks prior to surgery.
Near-infrared fluorescence imaging
Intraoperative imaging during surgery was performed using the laparoscopic high-definition fluorescence imaging system (Karl Storz GmbH & Co. KG, Tuttlingen, Germany). The system includes a light source for visible and 760 nm (ICG mode) light, a plasma light guide, and a 30°, 10 mm laparoscope containing optical filters. The system allows easy switching between white light and ICG modes using a foot pedal. Images were recorded using a charge-coupled camera device.
Ex vivo fluorescence imaging of resected tissue specimens was performed at the pathology department using the previously described fluorescence-assisted resection and exploration (FLARE®, Beth Israel Deaconess Medical Center, Boston, MA, USA) prototype surgical imaging system [11]. In addition, the location of ICG in resected tissue was assessed using fluorescence microscopy. Digital images were made using the Leica DM5500B digital microscope (Leica Microsystems B.V., Son, the Netherlands) equipped with a Leica DFC365FX camera and LAS X software (version 2.6.0) for image acquisition and processing.
Procedure
The procedure started with the inspection of the abdominal cavity for the presence of extrahepatic metastases. When none were found, the liver capsule was inspected, followed by NIR fluorescence imaging. Subsequently, LUS was performed by a dedicated radiologist. Each suspect lesion detected by inspection, fluorescence imaging, and/or LUS was resected when the surgeon considered it to be safe and relevant.
All resected liver lesions were routinely analyzed at the pathology department, and the method of detection was correlated with histopathological findings. Histopathological diagnosis was considered the gold standard. Sensitivity and positive predictive value of every resected lesion was calculated for all imaging modalities. Only malignant lesions were considered true positives. Statistical analysis was performed using SPSS version 22.0 software (SPSS, ©IBM Corporation, Somer, NY, USA).
Results
Patient characteristics
Twenty-two patients planned to undergo laparoscopic staging (n = 4) or resection (n = 19) of one or multiple tumors confined to the liver were included from April 2013 to November 2015. Patient characteristics are shown in Table 1. One patient, with a suspected intrahepatic cholangiocarcinoma, was included twice. First, he underwent a diagnostic laparoscopy followed by resection of the liver tumor 2 months later.
Preoperative working diagnosis differed from final histopathological diagnosis in four patients. One patient presented with a large, atypical mass in segments 2 and 3 was suspected to have (fibrolamellar) HCC by radiological imaging. Final diagnosis demonstrated focal nodular hyperplasia (FNH). The second patient, with a history of laparoscopic cholecystectomy, presented with abdominal pain and preoperative images showed a liver lesion suspicious for HCC. This lesion was found to be liver tissue herniated through one of the old trocar incisions. The third patient presented with a history of breast cancer and a FDG-PET-positive lesion in segment 4b, suspicious for metastasis. Instead, the final diagnosis was intrahepatic cholangiocarcinoma. The fourth patient was suspected to have an intrahepatic cholangiocarcinoma and simultaneous liver metastases of a non-small cell lung carcinoma (NSCLC). The large liver tumor suspicious for cholangiocarcinoma was not biopsied during the first procedure. Two other suspect lesions in the liver, either metastases of NSCLC or hepatic adenomas, were biopsied and diagnosed as hepatic adenomas. The large tumor was resected in a second procedure, and final histopathological evaluation indeed showed an intrahepatic cholangiocarcinoma.
Pre- and intraoperative tumor detection
No adverse events occurred due to ICG administration. Two patients (suffering from UMLM and CRLM) were excluded, because their procedure was postponed 3 and 6 days after ICG administration due to fever and logistical reasons. This delay resulted in intraoperative fluorescence signals too weak for sufficient guidance. In all other patients, fluorescence imaging of all types of tumors was successful (Fig. 1).
A total of 46 lesions, including 26 malignant tumors with a median size of 20 mm, were resected in the remaining 20 patients (Table 2). Sensitivity and positive predictive values of the imaging modalities are shown in Fig. 2. Of all resected malignancies, 20 % were missed by CT scan, 16 % by MRI scan, 38 % by inspection, 12 % by LUS, and 8 % by NIR fluorescence imaging. Sensitivity of all imaging modalities of lesions sized <10 mm dropped considerably. However, these differences were not statistically significant. The lesions missed by LUS were all superficially located. The lesions missed by intraoperative NIR fluorescence imaging (a CRLM and UMLM) were located >8 mm below the liver capsule. During gross examination at the pathology department, the resected CRLM did show rim-type fluorescence (Fig. 3). The other false-negative lesion was located several centimeters below the liver capsule, and diagnosis was confirmed after biopsy. A sensitivity of 100 % was reached when fluorescence imaging and LUS were combined.
No additional malignancies were identified only by intraoperative inspection. LUS alone identified one additional malignant tumor (Fig. 3B). NIR fluorescence imaging solely identified three additional malignancies in two patients suffering from CRLM. The first patient presented with a synchronous, solitary CRLM in segment 6, which partially responded to neoadjuvant chemotherapy. During laparoscopic metastasectomy, two additional lesions in segment 3 were visualized by typical rim-type fluorescence, whereupon resection of these lesions was performed (see Video 1 in ESM). Histopathological analysis confirmed the diagnosis of two metastatic intestinal-type adenocarcinomas of 1 and 3 mm, respectively. The second patient suffered from multiple CRLM resected by bi-segmentectomy. The additional occult lesion, sized 2 mm, was identified within the planned resection area.
Positive predictive values were 71 % (CT), 80 % (MRI), 52 % (inspection), 77 % (LUS), 75 % (NIR fluorescence imaging), and 70 % (LUS combined with NIR fluorescence imaging). The differences did not reach statistical significance. Lesions that appeared suspicious by NIR fluorescence imaging included a bile duct hamartoma, steatotic liver tissue, necrosis (3 times), cholestatic and inflamed liver tissue, FNH, and a biliary adenofibroma (Fig. 4). Other benign lesions, such as cysts and fibrosis, were negative for NIR fluorescence. In hindsight, four benign lesions were unnecessarily removed because inspection alone was positive. One benign lesion was removed because NIR fluorescence imaging alone was positive.
Fluorescence imaging resulted in clear intraoperative demarcation of tumors. Resection could be performed more accurately using fluorescence guidance (see Video 2 in ESM). Prior to resection, the planned margins could be checked again by LUS. Histopathological evaluation of all resected malignant tumors revealed a radical resection rate of 88 % (22/25). One large UMLM was only biopsied to confirm diagnosis, since multiple similar liver lesions were detected during surgery. In one patient, intraoperative NIR fluorescence imaging after resection showed a fluorescent margin, located on the right portal vein. LUS and inspection did not show any remaining tumor. Based on the latter results, and the goal of preserving as much liver volume as possible, it was decided not to extend the resection to a full hemihepatectomy. Ex vivo evaluation of the resected tissue showed a tumor-positive resection margin, suggesting that a full hemihepatectomy should have been considered.
In the second patient, the positive resection margin was in retrospect visible during surgery (Fig. 5). The positive resection margin in the third patient, suffering from a multinodular HCC, was not visible during surgery.
Discussion
The present study describes the largest series of intraoperative fluorescence imaging during minimally invasive oncological liver surgery. Laparoscopic resection of liver tumors is believed to have several advantages over open surgery: less intraoperative blood loss, lower morbidity rates, and decreased length of hospital stay [12, 13]. Importantly, overall and disease-free survival remains similar for patients with HCC and CRLM. However, implementation of the laparoscopic technique occurs slowly. In France for instance, currently approximately 15 % of all liver resections are performed laparoscopically [14]. The main concerns include technical feasibility, safety of the technique, and the substantial learning curve [15]. Indeed, depth perception and the range of motion are hampered by a lack of tactile feedback and three-dimensional vision, as well as by altered orientation and scale of the surgical field [16]. No randomized controlled trials exist, but one can imagine that, compared to open procedures, the more technically demanding laparoscopic approach may expose patients to a higher risk of R1 resection. A recent meta-analysis showing a significant lower incidence of R1 resections after laparoscopic resection of CRLM may be the result of a selection bias, as some tumor locations with a higher risk of incomplete resection, such as the posterior segments, make an open approach preferable [17]. NIR fluorescence guidance during laparoscopic oncologic liver surgery reveals the localization of the tumor, enhances demarcation, and hopefully results in fewer incomplete resections. The current study showed that no NIR fluorescence should be visible at the resection margin to ensure a surgical margin of at least 8 mm. The radical resection rate was 88 % (22 of 25 malignancies) which is comparable with the literature [18]. All three incompletely removed tumors were located in the technically more demanding segments 6, 7, and 8.
Two patients from the current study were excluded because fluorescence imaging several days after ICG injection resulted in fluorescence signals that were too low. Other studies described adequate fluorescence imaging up to 2 weeks after ICG administration [19]. Patients included in these studies underwent a standard-of-care ICG clearance test to assess liver function and received a dose of 0.5 mg/kg ICG. In the Netherlands, this test is not standard of care. Moreover, we have previously optimized dose and timing of administration resulting in a lower dose by a factor of 3–5 [8]. The two excluded patients demonstrate that if a procedure is postponed, adequate fluorescence imaging demands a repeated dose of ICG, a higher initial dose of ICG, or a more sensitive fluorescence imaging system.
The appearance of the fluorescence signal during surgery depends not only on ICG dose and timing of administration, but also on tumor type and localization. Superficial metastases are recognizable by rim-type fluorescence, while deeper located metastases are completely surrounded by liver tissue and thus show total staining. In the current study, ex vivo fluorescence imaging showed rim-type fluorescence of all liver metastases and of the intrahepatic cholangiocarcinoma, while HCC also showed partial fluorescence. After intravenous administration, ICG is rapidly eliminated from the blood via the liver with a half-life of 2–3 min. Retention of ICG around liver tumors is not only due to simple mechanical compression of bile ducts. Recent studies revealed an underlying molecular mechanism. The transition zone between tumor and healthy liver tissue is composed of dedifferentiated hepatocytes with a keratine-7-positive immature phenotype [8]. These hepatocytes show down-regulation of anion transporters and are consequently unable to transport ICG into biliary canaliculi [20]. ICG is thus entrapped around tumors in these immature hepatocytes. Normally differentiated hepatocytes throughout the liver have already excreted their ICG and appear dark, just like metastases from extrahepatic tumors and poorly differentiated HCC, resulting in high contrast ratios. In differentiated HCC, the portal uptake function is preserved, leading to the accumulation of ICG in the tumor itself [21]. A similar mechanism may play a role in ICG retention in FNH and biliary adenofibroma, as shown in this study (Fig. 4). Observations in resected liver tumors showed that ICG is not only preserved in fresh tissue, but also in paraffin-embedded tissue [22]. Ex vivo fluorescence imaging remains possible in samples as old as 3 years.
The laparoscopic imaging system used in this study, i.e., the Karl Storz HD fluorescence laparoscope, allows easy switching between white light modus and fluorescence modus using a foot pedal. A drawback of this system is that no overlay of fluorescence and white light images is available. This makes orientation during fluorescence imaging sometimes challenging. Several other laparoscopic fluorescence imaging systems are available, including the commercially available Pinpoint endoscopic fluorescence imaging system (Novadaq Technologies Inc, Toronto, Canada) [23] and FireFly fluorescence imaging for the da Vinci Si surgical robot (Intuitive Surgical, Inc., Sunnyvale, CA, USA) [24]. These two systems do possess an overlay function, which may improve ease of use.
Near-infrared light (700–900 nm) has the advantage of higher photon penetration into tissue and lower autofluorescence compared to the visible light spectrum (400–700 nm). The reported depth penetration is however limited to a maximum of ≈8 mm [25]. In the present study, both lesions missed by fluorescence imaging were located >8 mm below the liver surface. Although the missed CRLM did show rim-type fluorescence ex vivo (Fig. 3B), these lesions were intraoperatively only visible using LUS. This finding demonstrates that fluorescence imaging must be seen as a complementary technique to LUS. The combination of LUS and fluorescence imaging reached a sensitivity of 100 %. However, only suspect lesions were resected, and this value is therefore not accurate, just like specificity and negative predictive value. No significant differences were found because this study was not designed and powered to do so. Deeper located liver tumors may also be visualized using intraoperative photoacoustic tomography [26]. This technique combines the specific uptake of ICG by some liver tumors with enhanced depth penetration of ultrasonography. Although feasible, technical improvements are required to make this technique available for clinical use.
Multiple studies illustrated the highly sensitive intraoperative detection of HCC and CRLM using fluorescence imaging [7, 8, 10, 21]. However, only one small study and three case reports describe this technique during minimally invasive liver surgery [9, 27–29]. Our group previously reported the feasibility of UMLM detection in three patients during laparoscopic resection [9]. Additional metastases were identified in two patients. Kudo et al. showed fluorescent detection of 12 out of 16 HCCs and 11 out of 16 CRLM in 17 patients [27]. Contrary to our current study, no comparison was made between lesions detected by fluorescence imaging and by other imaging modalities. Moreover, no information was provided about false-positive lesions detected by fluorescence imaging. The rather disappointing results of this study may be the result of a less sensitive imaging system, a suboptimal ICG dose, or variations in timing of ICG administration. To improve homogeneity, we chose to use a fixed ICG dose and to administer the dose the day before surgery. This strategy allowed visualization of all included tumors in vivo or ex vivo.
Fluorescence imaging can assist in differentiating between benign and malignant lesions, such as cysts, fibrosis, and hemangiomas. In the current study, four necrotic lesions were suspicious using fluorescence imaging. These lesions were resected in two CRLM patients who received neoadjuvant therapy. It may be that these lesions were in fact tumors that fully responded to the chemotherapy. In addition, two other resected lesions (a biliary adenofibroma and FNH) were considered false-positive, because they were benign. Nonetheless, imaging of these large lesions (18–84 mm) was still relevant as these lesions were preoperatively planned to be resected. Other studies describing fluorescence imaging during laparoscopic resection of liver tumors do not mention false-positivity rates.
Three occult, otherwise undetected, liver tumors (12 %) were identified in two patients suffering from CRLM. Other studies describe similar results. van der Vorst et al. [8] identified additional lesions in 12.5 % (5 of 40) of patients suffering from CRLM. Ishizawa et al. [21] examined resected liver specimens of patients with HCC and identified 7.7 % (21 of 273) additional HCCs that were not identified by gross examination. A key unanswered question is whether these additional lesions are “harbingers” of even more tumors not yet visible by any means or the only sites of disease that would otherwise have not been resected. One patient in the current study developed multiple liver metastases 3 months after surgery. The second patient is still disease-free after 6 months. Of the five patients with additional detected tumors in the study of van der Vorst et al. [8], two developed hepatic recurrence within 1 year, but three are currently still disease-free after a period of 3–6 years. Although these results should be interpreted cautiously, it appears that NIR fluorescence imaging can indeed prevent recurrence in some patients.
This study demonstrates the added value of intraoperative navigation using NIR fluorescence imaging during laparoscopic resection of a broad variety of malignant liver tumors. It is an easy, effective, and safe method. NIR fluorescence imaging can assist in localization and demarcation of known tumors, as well as identification of otherwise undetectable occult liver tumors. Large studies are required to confirm whether fluorescence-guided resection of liver tumors can improve radical resection rates and patient outcomes, but based on our results, we believe this method could quickly be an important component of laparoscopic resection of liver tumors.
References
Cummings LC, Payes JD, Cooper GS (2007) Survival after hepatic resection in metastatic colorectal cancer: a population-based study. Cancer 109(4):718–726
Hsu CY, Liu PH, Hsia CY, Lee YH, Nagaria TS, Lee RC, Lin HC, Huo TI (2016) Surgical resection is better than transarterial chemoembolization for patients with hepatocellular carcinoma beyond the milan criteria: a prognostic nomogram study. Ann Surg Oncol 23(3):994–1002
Feng Q, Chi Y, Liu Y, Zhang L, Liu Q (2015) Efficacy and safety of percutaneous radiofrequency ablation versus surgical resection for small hepatocellular carcinoma: a meta-analysis of 23 studies. J Cancer Res Clin Oncol 141(1):1–9
Karanjia ND, Lordan JT, Fawcett WJ, Quiney N, Worthington TR (2009) Survival and recurrence after neo-adjuvant chemotherapy and liver resection for colorectal metastases: a ten year study. Eur J Surg Oncol 35(8):838–843
Franssen B, Jibara G, Tabrizian P, Schwartz ME, Roayaie S (2014) Actual 10-year survival following hepatectomy for hepatocellular carcinoma. HPB (Oxford) 16(9):830–835
Rethy A, Lango T, Marvik R (2013) Laparoscopic ultrasound for hepatocellular carcinoma and colorectal liver metastasis: an overview. Surg Laparosc Endosc Percutan Tech 23(2):135–144
Ishizawa T, Fukushima N, Shibahara J, Masuda K, Tamura S, Aoki T, Hasegawa K, Beck Y, Fukayama M, Kokudo N (2009) Real-time identification of liver cancers by using indocyanine green fluorescent imaging. Cancer 115(11):2491–2504
van der Vorst JR, Schaafsma BE, Hutteman M, Verbeek FP, Liefers GJ, Hartgrink HH, Smit VT, Lowik CW, van de Velde CJ, Frangioni JV, Vahrmeijer AL (2013) Near-infrared fluorescence-guided resection of colorectal liver metastases. Cancer 119(18):3411–3418
Tummers QR, Verbeek FP, Prevoo HA, Braat AE, Baeten CI, Frangioni JV, van de Velde CJ, Vahrmeijer AL (2015) First experience on laparoscopic near-infrared fluorescence imaging of hepatic uveal melanoma metastases using indocyanine green. Surg Innov 22(1):20–25
Boogerd LS, Handgraaf HJ, Lam HD, Braat AE, Baranski AG, Swijnenburg RJ, Frangioni JV, Vahrmeijer AL, Ringers J (2016) Application of near-infrared fluorescence imaging during modified associating liver partition and portal vein ligation for staged hepatectomy. Surgery 159(5):1481–1482
Troyan SL, Kianzad V, Gibbs-Strauss SL, Gioux S, Matsui A, Oketokoun R, Ngo L, Khamene A, Azar F, Frangioni JV (2009) The FLARE intraoperative near-infrared fluorescence imaging system: a first-in-human clinical trial in breast cancer sentinel lymph node mapping. Ann Surg Oncol 16(10):2943–2952
Allard MA, Cunha AS, Gayet B, Adam R, Goere D, Bachellier P, Azoulay D, Ayav A, Navarro F, Pessaux P (2015) Early and long-term oncological outcomes after laparoscopic resection for colorectal liver metastases: a propensity score-based analysis. Ann Surg 262(5):794–802
Ciria R, Cherqui D, Geller DA, Briceno J, Wakabayashi G (2016) Comparative Short-term Benefits of Laparoscopic Liver Resection: 9000 Cases and Climbing. Ann Surg 263(4):761–777
Farges O, Goutte N, Dokmak S, Bendersky N, Falissard B (2014) How surgical technology translates into practice: the model of laparoscopic liver resections performed in France. Ann Surg 260(5):916–921
Wakabayashi G, Cherqui D, Geller DA, Buell JF, Kaneko H, Han HS, Asbun H, O’Rourke N, Tanabe M, Koffron AJ, Tsung A, Soubrane O, Machado MA, Gayet B, Troisi RI, Pessaux P, Van Dam RM, Scatton O, Abu HM, Belli G, Kwon CH, Edwin B, Choi GH, Aldrighetti LA, Cai X, Cleary S, Chen KH, Schon MR, Sugioka A, Tang CN, Herman P, Pekolj J, Chen XP, Dagher I, Jarnagin W, Yamamoto M, Strong R, Jagannath P, Lo CM, Clavien PA, Kokudo N, Barkun J, Strasberg SM (2015) Recommendations for laparoscopic liver resection: a report from the second international consensus conference held in Morioka. Ann Surg 261(4):619–629
Hallet J, Gayet B, Tsung A, Wakabayashi G, Pessaux P (2015) Systematic review of the use of pre-operative simulation and navigation for hepatectomy: current status and future perspectives. J Hepatobiliary Pancreat Sci 22(5):353–362
Luo LX, Yu ZY, Bai YN (2014) Laparoscopic hepatectomy for liver metastases from colorectal cancer: a meta-analysis. J Laparoendosc Adv Surg Tech A 24(4):213–222
Nguyen KT, Gamblin TC, Geller DA (2009) World review of laparoscopic liver resection-2804 patients. Ann Surg 250(5):831–841
Lim C, Vibert E, Azoulay D, Salloum C, Ishizawa T, Yoshioka R, Mise Y, Sakamoto Y, Aoki T, Sugawara Y, Hasegawa K, Kokudo N (2014) Indocyanine green fluorescence imaging in the surgical management of liver cancers: current facts and future implications. J Visc Surg 151(2):117–124
de Graaf W, Hausler S, Heger M, van Ginhoven TM, van Cappellen G, Bennink RJ, Kullak-Ublick GA, Hesselmann R, van Gulik TM, Stieger B (2011) Transporters involved in the hepatic uptake of (99 m)Tc-mebrofenin and indocyanine green. J Hepatol 54(4):738–745
Ishizawa T, Masuda K, Urano Y, Kawaguchi Y, Satou S, Kaneko J, Hasegawa K, Shibahara J, Fukayama M, Tsuji S, Midorikawa Y, Aburatani H, Kokudo N (2014) Mechanistic background and clinical applications of indocyanine green fluorescence imaging of hepatocellular carcinoma. Ann Surg Oncol 21(2):440–448
Shimada S, Ohtsubo S, Ogasawara K, Kusano M (2015) Macro- and microscopic findings of ICG fluorescence in liver tumors. World J Surg Oncol 13(198). doi:10.1186/s12957-015-0615-5
Fengler J (2015) Near-infrared fluorescence laparoscopy-technical description of PINPOINT(R) a novel and commercially available system. Colorectal Dis 17(Suppl 3):3–6
Tobis S, Knopf J, Silvers C, Yao J, Rashid H, Wu G, Golijanin D (2011) Near infrared fluorescence imaging with robotic assisted laparoscopic partial nephrectomy: initial clinical experience for renal cortical tumors. J Urol 186(1):47–52
Vahrmeijer AL, Hutteman M, van der Vorst JR, van de Velde CJ, Frangioni JV (2013) Image-guided cancer surgery using near-infrared fluorescence. Nat Rev Clin Oncol 10(9):507–518
Miyata A, Ishizawa T, Kamiya M, Shimizu A, Kaneko J, Ijichi H, Shibahara J, Fukayama M, Midorikawa Y, Urano Y, Kokudo N (2014) Photoacoustic tomography of human hepatic malignancies using intraoperative indocyanine green fluorescence imaging. PLoS ONE 9(11):e112667
Kudo H, Ishizawa T, Tani K, Harada N, Ichida A, Shimizu A, Kaneko J, Aoki T, Sakamoto Y, Sugawara Y, Hasegawa K, Kokudo N (2014) Visualization of subcapsular hepatic malignancy by indocyanine-green fluorescence imaging during laparoscopic hepatectomy. Surg Endosc 28(8):2504–2508
Kawaguchi Y, Nagai M, Nomura Y, Kokudo N, Tanaka N (2015) Usefulness of indocyanine green-fluorescence imaging during laparoscopic hepatectomy to visualize subcapsular hard-to-identify hepatic malignancy. J Surg Oncol 112(5):514–516
Sakoda M, Ueno S, Iino S, Hiwatashi K, Minami K, Kawasaki Y, Kurahara H, Mataki Y, Maemura K, Uenosono Y, Shinchi H, Natsugoe S (2014) Anatomical laparoscopic hepatectomy for hepatocellular carcinoma using indocyanine green fluorescence imaging. J Laparoendosc Adv Surg Tech A 24(12):878–882
Smith JJ, D’Angelica MI (2015) Surgical management of hepatic metastases of colorectal cancer. Hematol Oncol Clin North Am 29(1):61–84
Acknowledgments
The authors gratefully acknowledge H.A.J.M. Prevoo for her support and immunohistochemical expertise. We thank David J. Burrington Jr. for editing.
Funding
This work was supported in part by the Dutch Cancer Society Grant UL2010-4732 and National Institutes of Health Grant R01-CA-115296. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Disclosures
Dr. Frangioni is CEO of Curadel, LLC, a for-profit company that has licensed FLARE® technology from the Beth Israel Deaconess Medical Center. Drs. Boogerd, Drs. Handgraaf, Drs. Lam, Dr. Huurman, Dr. Farina-Sarasqueta, Dr. van de Velde, Dr. Braat, and Dr. Vahrmeijer have no conflicts of interest or financial ties to disclose.
Additional information
Leonora S. F. Boogerd and Henricus J. M. Handgraaf have contributed equally and share first authorship.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Supplementary material 1 (WMV 121385 kb)
Supplementary material 2 (WMV 155111 kb)
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
Boogerd, L.S.F., Handgraaf, H.J.M., Lam, HD. et al. Laparoscopic detection and resection of occult liver tumors of multiple cancer types using real-time near-infrared fluorescence guidance. Surg Endosc 31, 952–961 (2017). https://doi.org/10.1007/s00464-016-5007-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00464-016-5007-6