Abstract
Background: During complex laparoscopic operations, the surgeon often has to use both instruments to one side of the telescope (off-optical axis work). This experimental study was undertaken to compare this orthodox versus the off-optical axis endoscopic manipulations regarding the performance parameters and motion analysis and muscle work of the surgeon's dominant upper limb. Methods: Ten surgeons participated in the study; each sutured 50-mm enterotomy in pig's small bowel in each of three setups: (1) in-optical axis manipulation (one instrument on either side of the laparoscope) (2) off-optical axis manipulation (both instruments on one side of the laparoscope to the dominant hand of the surgeon), and (3) off-optical axis manipulation both instruments on one side of the laparoscope on the nondominant side). The main outcome measures were the placement error score, execution time, leakage pressure, motion analysis, and telemetric electromyography parameters of the surgeon's dominant upper limb. Results: There was no significant difference in all parameters of performance, muscle work, and fatigue between setup 1 and setup 3. However, marked degradation of all parameters of performance with increased muscle work and fatigue was observed with setup 2 compared to setups 1 and 3. The reason for the deterioration with setup 2 is related to the altered "monitor display angle" which are different from the actual physical angles. With this setup, the instrument-to-target physical angle of 30° appears on the screen as ?30° and this disturbs both the manipulation and the azimuth angles obscuring the needle–tissue entry point. In addition, the instrument casts a shadow on its medial side and this tends to obscure the exact relations between instrument, needlepoint, and the tissue. Conclusions: Off-optical axis work is a good alternative to the orthodox setup provided the instruments are placed to the nondominant hand. The marked degradation in performance encountered during off-optical axis work to the dominant hand of the surgeon is due to the resulting altered monitor display angles. The importance of these monitor display angles in influencing task performance has been previously overlooked.
Similar content being viewed by others
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Emam, T., Hanna, G. & Cuschieri, A. Comparison of orthodox versus off-optical axis endoscopic manipulations . Surg Endosc 16, 401–405 (2002). https://doi.org/10.1007/s00464-001-8137-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00464-001-8137-3