Abstract
Biomarker analysis for colorectal cancer has been shown to be reliable in Europe with 97% of samples tested by EQA participants to be correctly classified. This study focuses on errors during the annual EQA assessment. The aim was to explore the causes and actions related to the observed errors and to provide feedback and assess any improvement between 2016 and 2017. An electronic survey was sent to all laboratories with minimum one genotyping error or technical failure on ten tumor samples. A workshop was organized based on 2016 survey responses. Improvement of performance in 2017 was assessed for returning participants (n = 76), survey respondents (n = 13) and workshop participants (n = 4). Survey respondents and workshop participants improved in terms of (maximum) analysis score, successful participation, and genotyping errors compared to all returning participants. In 2016, mostly pre- and post-analytical errors (both 25%) were observed caused by unsuitability of the tumor tissue for molecular analysis. In 2017, most errors were due to analytical problems (50.0%) caused by methodological problems. The most common actions taken (n = 58) were protocol revisions (34.5%) and staff training (15.5%). In 24.1% of issues identified no action was performed. Corrective actions were linked to an improved performance, especially if performed by the pathologist. Although biomarker testing has improved over time, error occurrence at different phases stresses the need for quality improvement throughout the test process. Participation to quality improvement projects and a close collaboration with the pathologist can have a positive influence on performance.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Metastatic colorectal carcinoma (mCRC) is the third most commonly diagnosed malignancy and the fourth leading cause of cancer death worldwide [1]. Besides standard chemotherapy, mCRC patients are currently receiving personalized treatment by anti-epidermal growth factor receptor (EGFR) monoclonal antibodies, which has been shown to significantly increase the median survival time from 18.5 to 23.5 months of mCRC patients [2].
In 2008, mutations in exon 2 of the Kirsten rat sarcoma viral oncogene homolog (KRAS) gene were shown to be a negative predictor for anti-EGFR therapy benefit [2, 3]. In 2013, the same was demonstrated for mutations in KRAS exons 3 and 4, and for the less frequent mutations in neuroblastoma rat sarcoma (NRAS) viral oncogene homolog exon 2–4 [4, 5], resulting in an extension of the drug labels for cetuximab and panitumumab by the European Medicine Agency (EMA) [6, 7]. Consequently, molecular diagnostic laboratories were challenged to include these new test requirements in a correct and timely manner [4].
Since 2009, the European Society of Pathology (ESP) has been involved in the organization of a yearly colon external quality assessment (EQA) scheme to assess and improve RAS biomarker analysis in mCRC [8, 9]. Based on the updated requirements, the 2013 ESP colon EQA scheme was expanded by the assessment of full RAS testing (exon 2, 3, and 4 of both KRAS and NRAS) [10]. Since that same year, laboratories could also optionally test the BRAF (B-Raf proto-oncogene) gene, which has demonstrated prognostic value and is increasingly being analyzed in Europe [11].
Results from the 2013 scheme revealed that full RAS testing was only implemented by half of the laboratories (49.3%, n = 131 laboratories) and that there were numerous errors in testing the new gene segments [10]. In addition, EQA data confirmed that molecular diagnostic laboratories in Europe are using a large variation in methods for (a) the estimation of the neoplastic cell content [12], (b) for DNA extraction [13], and (c) for determining the RAS and BRAF status [13].
A 2016 study showed that the vast majority of samples (97%) tested by laboratories participating to an EQA scheme had been correctly classified. For about 2% of samples tested, an incorrect outcome was obtained that could potentially lead to a different anti-EGFR therapy advice [14]. Given the potential impact of predictive biomarker analyses on patient outcome, it is important to evaluate the exact causes of errors and to provide tailored feedback to diagnostic laboratories for quality improvement [15]. In turn, laboratories are encouraged to implement the necessary corrective and preventive actions (CAPA) as a required by the ISO15189 standard [16] or national equivalents, and the Clinical Laboratory Improvement Amendments of 1988 [17].
In clinical biology and forensics, error causes have been shown to occur mostly during the pre- (46–86%) and post-analytical (18–47%) phases of the total test process (TTP) compared to the analytical phase (7–13%) [18, 19], although the lack of standardization in taxonomy accounts for some of the variation seen in these error rates [20].
Although EQA schemes reflect the performance of diagnostic laboratories, more detailed information is required on the error causes and distribution throughout the TTP for molecular cancer diagnostics, as well as the actions undertaken by laboratories to improve quality in the long-term [21].
Therefore, the objectives of this study were (a) to evaluate the causes, distribution, and follow-up of laboratory errors from laboratories participating to the ESP colon EQA scheme; (b) to provide feedback to laboratories as to how practice can be improved, and (c) to assess potential improvement between 2016 and 2017 EQA schemes.
Material and methods
The 2016 and 2017 ESP colon EQA schemes were organized according to the ISO 17043 standard for proficiency testing [22] and the guideline on the requirements of external quality assessment programs in molecular pathology [23]. Participation to EQA was free of choice and open to all laboratories worldwide. Details on validation, results submission, and feedback provided to the laboratories have been previously described ([13], Supplemental Table 1).
At the end of both EQA schemes, all laboratories with at least one major genotyping error, a score “i,” or technical failure (in which no result could be obtained for a case) in one of the ten provided formalin-fixed paraffin-embedded cases were invited by e-mail to complete an electronic survey with both laboratory-specific (general) questions and case-specific questions for each observed error. A list of definitions was included to clarify all questionnaire terms (Supplemental Table 2). Data was collected for 1 month, laboratories received a first reminder after 14 days and a second the day before the deadline.
All participants to the 2016 EQA scheme were invited to attend a 1.5-day long optional workshop, organized in December 2016 at the Radboud University Medical Center, The Netherlands. Topics were based on the 2016 survey output and included issues occurring in the pre-, post-, and analytical phase as cited by the survey respondents. A separate microscopy session focusing on the estimation of neoplastic cell content was held outside this project (Dufraing et al., submitted for publication).
Improvement of RAS testing was evaluated between both ESP colon EQA scheme years on three levels: (a) laboratories who participated in both schemes, (b) 2016 survey respondents, and (c) participants to the 2016 workshop. For these three categories, the average genotyping score, percentage of participants with the maximum score of 20, the percentage of successful participants, and re-occurrence of genotyping errors and/or technical failures were assessed.
Response bias was assessed by investigating the difference in laboratory characteristics between survey respondents and non-responders. Missing data were reported in the tables accordingly and not included in the statistical analysis. The reported accreditation statuses and laboratory settings were validated on the websites of the relevant national accreditation bodies and the laboratories’ website, respectively. Comparison of categorical variables was performed using chi-squared (Χ2) tests or a Fisher’s exact (FE) test if one of the row or column cells counted below five. For the difference in the sample amounts tested and people involved in the laboratory between responders and non-respondents, categories were treated as ordinal data following a Mann-Whitney U (MWU) test. For a combination of categorical and continuous variables (e.g., improvement of the average genotyping score between more than two groups) a one-way ANOVA with Tukey’s HSD was performed. Bonferroni corrections were applied when necessary. The significance level was set at α = 0.05. All statistical analyses were performed using SPSS Statistics Subscription version 1.0.0.903 (IBM, Armonk, NY, USA). Graphs were created using Microsoft Excel Professional Plus 2013.
Results
ESP Colon EQA scheme results
In the 2016 and 2017 colon EQA schemes, 123 laboratories from 27 countries and 105 from 29 countries participated, respectively. Seventy-six laboratories participated in both EQA schemes. They displayed a significant correlation between the average genotyping scores in 2016 and 2017 (Spearman R = 0.29, p = 0.011). Participants with a genotyping error or the maximum score in 2016 were more likely to obtain a genotyping error (p = 0.032) and reach the maximum score (p = 0.022) in 2017.
In 2017, the average genotyping score was 82.5% and the successful participation according to pre-defined scoring criteria [23] was 57.1% (60/105). In addition, 45.7% (48/105) laboratories obtained the maximum score of 20/20. In 2017, the number of participants making a genotyping error was 41.9% (44/105), whereas the number of participants with a technical failure was 3 participants (2.9%).
The total number of genotyping errors and technical failures on sample level is shown in Table 1.
The proportion of samples misclassified was 4.6% (56/1230) in 2016 and 6.1% (64/1050 samples) in 2017. The average genotyping score, the number of participants with a successful participation and the number of technical errors were lower in the 2017 compared to the 2016 EQA scheme. The number of genotyping errors were higher in 2017, but not related to (a) new participants, (b) laboratories who switched methods, or (c) used a specific method type.
Characteristics of survey respondents
Based on the EQA results, 51 and 49 laboratories received the survey in 2016 and 2017, respectively. Twenty-two (43.1%) participants in 2016 and 18 (36.7%) in 2017 responded within 20 days. Data from one survey participant in 2016 was not taken into account for further analysis, as only one of the questions was answered. Response rates did not differ depending on the country, or whether they had completed the previous (2016) survey.
The laboratory characteristics during the 2016 and 2017 EQA schemes are shown in Table 2. For both schemes most respondents performed RAS and BRAF analysis in a routine clinical setting using commercial kits. The majority were not accredited for molecular analysis and were situated in a university or general hospital. For most of the respondents the analysis was performed under the department of pathology (61.9% and 88.9% in 2016 and 2017, respectively), and included on average between 1 and 10 people. Six (28.6%) laboratories that participated in the 2016 scheme responded that the analysis was performed by another laboratory (compared to 0.0% in 2017). Of these, 5 laboratories outsourced the evaluation of the neoplastic cells, and 1 the DNA extraction step. For all participants, the estimation of the percentage of neoplastic cells was performed by a pathologist.
Laboratory characteristics collected during the EQA scheme for those participating in the survey were compared to the non-respondents. In 2016, the survey participants were less likely to have performed the analysis under the pathology department compared to non-participants. Similarly, the 2016 respondents were more likely to have outsourced the analysis to another laboratory (Table 2).
Error cause analysis
Responses to the case-specific questions resulted in a total of 35 (2016) and 24 (2017) issues that were further analyzed. The issues examined in this study comprised 42.9% and 39.1% of the total genotyping errors and 66.7% and 25.0% of the technical failures observed in the 2016 and 2017 EQA schemes, respectively. An overview of case-specific and laboratory-specific answers is given in Table 3.
The majority of the 2016 errors (37.1%) occurred in the post-analytical phase of the testing process, compared to analytical problems in 2017 (50.0%). “Tissue problems” caused by the insuitability of the tumor tissue (e.g., insufficient amount of neoplastic cells or degradation of the DNA), and methodological problems were the most frequent detailed causes. In 2017, problems were more frequently detected before release of the final EQA results, and more often no CAPA was undertaken. Looking at all test phases, only laboratories with an error in the pre-analytical phase were less likely to obtain a maximum score in 2017 (p = 0.031). There was no difference in the number of errors in subsequent test phases and their specific causes compared to genotyping errors, technical failures, successful participations, or maximum scores obtained in 2017.
In both years, occurrence throughout the TTP differed significantly for different analysis methods (KRAS p = 0.019, NRAS p = 0.044, BRAF p = 0.006). Analytical and post-analytical errors occurred more for commercial kits, compared to pre-analytical errors for non-commercial users. However, specific error causes and the CAPAs undertaken were not linked to a certain methodology.
Corrective/preventive actions
On average between 1 and 2 persons were included in carrying out the respective CAPA although errors in 2017 required more often involvement of the laboratory director compared to the (lead) technician in 2016 [Table 3]. There was no link between the phase or cause of the problem and the number or occupation of persons involved. However, only errors followed-up by the pathologist, were less likely to result in a genotyping error in 2017 and were more likely to result in a successful participation (both p = 0.012).
The most performed CAPAs included protocol revisions (n = 20) and staff trainings (n = 9). The CAPA type was linked to the cause of the errors, but not to a test phase [Fig. 1]. For 14 problems, no action was undertaken at all. Seven of them included problems with the tissue material [Fig. 1]. In 2016, the type of CAPA was correlated to less genotyping errors, successful participation (both p = 0.027), and obtaining the maximum score (p = 0.045) in the 2017 EQA scheme, especially for protocol revisions. Time of error registration (before or after the release of the EQA results) had no influence on the next scheme’s performance.
At laboratory level, more laboratories changed their method or protocol in 2016 compared to 2017 (Table 3). In both years, interpretation as well as reporting of the results was mainly performed by the molecular biologist and pathologist. Whereas the pathologist mainly interpreted results of commercial kits, non-commercial methods were mainly interpreted by the laboratory director.
In case a pathologist was involved in reporting, participants were more likely to obtain no genotyping errors (p = 0.15), a higher genotyping score (p = 0.034), the maximum score (p = 0.028), and a successful participation (p = 0.015) in 2017. This was not the case for the interpretation or reporting by any of the other responsible persons.
Feedback to laboratories
Ten participants from six laboratories at different countries (Austria, Germany, Israel, Portugal, Romania, and Turkey) accepted the invitation to attend the workshop. From those six institutes who attended, four of them also completed the 2016 survey and participated again in the 2017 scheme. Attendees scored the quality and usefulness for routine implementation of the workshop at 95 and 89 on 100 points, respectively. Participants responded that the main hurdles to overcome related to biomarker testing were routine problems including time and staff constraints (8/10), organizational and institutional barriers (5/10), an increasing workload (4/10), or costs or reimbursement issues (3/10).
The improvement in 2017 was evaluated for three groups: (a) laboratories participating in both schemes who received individual feedback (n = 76), (b) survey respondents (n = 13), and (c) workshop participants (n = 4) (Fig. 2). The number of laboratories making a genotyping error in 2017 (p = 0.036) increased significantly for returning EQA participants, in contrast to survey respondents and workshop participants. For those last two groups, an increase was observed in the average genotyping score (p = 0.037) and the percentage of laboratories obtaining the maximum score (p = 0.039), respectively.
Discussion
Accurate biomarker tests are crucial to determine appropriate treatment options for mCRC patients. To further improve the standard of biomarker testing, diagnostic laboratories are encouraged [16, 17, 24, 25] to implement measures for continual quality improvement, including CAPAs, education of laboratory personnel, and participation to EQA to compare the laboratory’s performance to peers and identify improvement priorities. This study focused on laboratories that reported an error during the annual EQA assessment. It included an in-depth analysis of EQA results to assess the influence of the exact error causes and their follow-up on performance, which have been reported in other fields besides molecular pathology [15, 18,19,20]. It included a survey and evaluation of customized feedback provided to the participant laboratories.
EQA participation has been shown to reflect RAS testing performance in routine practice [14]. This was confirmed by this study by a significant link between recurring errors and a lower average analysis score for participants who performed less in the first EQA scheme. This also suggests that EQA might exert a positive influence on laboratory performance, as previously reported for non-small cell lung cancer [21]. The results of this study demonstrated 6.1% of samples misclassified in 2017. Given the impact of the biomarker status on treatment choice it is important to continue improving biomarker testing.
Active participation to quality improvement projects aids laboratories in the critical evaluation of their results, as shown by the improved performance for workshop participants and survey respondents compared to general participants. Indeed, protocol revisions were frequently reported as CAPAs in the survey, and performing this CAPA type led to less errors and a better score in the next scheme. These revisions might be technical (e.g., a change to the analysis protocol) or general of nature (e.g., a general change to prevent errors from occurring such as building in a second check step when entering the results in to the online system). Moreover, the fact that the type of action performed (instead of type of error) influences the performance in the next scheme, suggests an active role for laboratories in quality improvement.
Survey respondents were a good representation of EQA participants, and error monitoring was not restricted to larger laboratories, laboratories in a research setting or who are accredited for molecular pathology. Although receiving accreditation was not linked to a better performance in this study, it has previously been shown to aid in the successful implementation of a new biomarker [26]. These surveys had the advantage of a standardized taxonomy, which allows to monitor error causes on a longitudinal level. The availability of multiple international laboratories’ data enables to link error causes to specific laboratory characteristics and methodologies. This can reveal systematic shortcomings and critical points in the TTP, eventually guiding molecular diagnostic laboratories.
In terms of continuous education, many laboratories did not perform additional training for results interpretation besides a person’s educational degree. Although training of the staff for a specific methodology should be well documented, and re-evaluated at frequent intervals [16], this was not reflected in the EQA performance.
Analysis of 56.2% technical failures and 40.8% of genotyping errors in both schemes combined, stresses the need of risk analysis in the TTP instead of merely the analytical phase. Consistent with previous results [15, 18], the pre- and post-analytical phases constituted a high fraction of the observed causes. In addition, as pre-cut and pre-labeled slides were provided to participants, an evaluation of the pre-analytical errors in routine practice of prior steps (deparaffinization, cutting, labeling) is advisable [27] as well as of errors at phases outside the laboratory’s responsibility. Namely, errors were reported in the pre-pre-analytical phase (from test request to sample reception at the laboratory) and the post-post-analytical phase (interpretation of the reported results by the clinician and making the appropriate therapy decision), albeit in other fields [15, 18,19,20].
This study demonstrates that pre-analytical errors were more likely to result in not obtaining the maximum score in the next scheme, and that a close involvement of the pathologist in results reporting and error follow-up contributes to a better scheme performance and less pre-analytical problems, especially when using a commercial kit, in line with a previous longitudinal study [13]. This stresses the importance for standardization of the neoplastic cell content determination for test outcome interpretation in mCRC [13] (Dufraing et al., submitted for publication). This is supported by the observation that only for 1 out of 12 cases for which the laboratories reported that the tumor tissue was not optimally suited for analysis in 2016, this was good practice, as it was indeed a case without neoplastic cells. Coincidently, survey respondents in 2016 were less likely to perform the analysis at the department of pathology and more frequently outsourced the selection of the neoplastic cell to another laboratory. Therefore, it might be useful to analyze a larger dataset or to evaluate non-conformities in routine practice to evaluate if these responder characteristics might have skewed the data and if non-conformities observed during routine reflect non-conformities reported during EQA, as even more challenging cases might occur in routine.
In 2017, more (analytical) methodological and personnel errors were observed, and more frequently no CAPA was implemented compared to the pre-analytical issues reported in 2016. This is surprising, as this is a requirement of the ISO 15189 and similar quality framework. Also, CAPAs were more likely to be monitored by the laboratory director at the expense of the laboratory technicians and were performed more often before the official release of the EQA results. This might suggest that these analytical problems are considered to be more severe by participants as compared to pre- and post-analytical problems in 2016, and direct follow-up may be more difficult. Indeed, reported causes included (a) unknown factors for which the manufacturer needed to be contacted or (b) a variant that was not included in the method for analysis, not linked to a specific methodology. Surprisingly, in spite of the large number of NGS users, none of the laboratories included a bio-informatician to interpret the results [28]. However, it must be noted that not all survey respondents in 2016 (n = 24) registered again in the next EQA scheme of 2017, as yearly participation is not required to demonstrate high quality performance. Therefore, we contacted those participants (n = 8) to ask for the reasons of refraining from participation. Two laboratories mentioned they only participate once every 2 years. One laboratory merged with another institute and therefore stopped RAS analyses, while another laboratory experienced bureaucratic issues with the payment of the registration fee. One participant did not agree with their awarded analysis score in 2016. The other three laboratories did not respond.
To interpret the error rates in the EQA schemes there are four points that need to be taken into account: (a) More samples were included containing a KRAS variant. However, no differences were observed when re-calculating the error rates based on the number of included samples per gene. (b) The ten distributed samples each had a different origin. Error rates were highest for a case containing the c.436G > A p.(Ala146Thr) variant (15.4%, n = 123) in 2016, and for the c.176C > A p.(Ala59Glu) variant (24.8%, n = 105) in 2017. The reason is that laboratories may be using an analysis method which may not include all necessary codons, consistent with previous EQA schemes [10]. (c) Many laboratories incorrectly analyzed the sample without any neoplastic cells, for which numbers and consequences have been previously described [13]. (d) Pre-defined scoring criteria differed as laboratories with an error in the online datasheet but correct written report received full points in 2017 and no points in 2016. However, this had no influence on the scores in this study.
As a conclusion, quality improvement projects such as the study described here are important to further improve the current high standards of biomarker testing in Europe. To avoid any issues with testing, laboratories need to work according to pre-defined procedures and document any changes. Laboratories need to be aware that reporting and monitoring of errors is required for quality improvement. To assure quality of biomarker analysis, it is thus clear that a holistic approach [29] is needed at all phases in combination with quality improvement projects within the laboratory and organized by EQA providers.
Data availability
The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.
Abbreviations
- BRAF :
-
B-Raf proto-oncogene
- EGFR :
-
Epidermal growth factor receptor
- ESP:
-
European Society of Pathology
- FE:
-
Fisher’s exact test
- KRAS :
-
Kirsten rat sarcoma viral oncogene homolog
- mCRC:
-
Metastatic colorectal carcinoma
- MWU:
-
Mann-Whitney U test
- NGS :
-
Next-generation sequencing
- NRAS :
-
neuroblastoma rat sarcoma
- WT:
-
Wild-type
- Χ 2 :
-
Chi-squared test
References
Arnold M, Sierra MS, Laversanne M, Soerjomataram I, Jemal A, Bray F (2017) Global patterns and trends in colorectal cancer incidence and mortality. Gut 66(4):683–691. https://doi.org/10.1136/gutjnl-2015-310912
Dattatreya S (2013) Metastatic colorectal cancer-prolonging overall survival with targeted therapies. South Asian J Cancer 2(3):179–185. https://doi.org/10.4103/2278-330X.114152
Amado RG, Wolf M, Peeters M, Van Cutsem E, Siena S, Freeman DJ, Juan T, Sikorski R, Suggs S, Radinsky R, Patterson SD, Chang DD (2008) Wild-type KRAS is required for panitumumab efficacy in patients with metastatic colorectal cancer. J Clin Oncol 26(10):1626–1634. https://doi.org/10.1200/JCO.2007.14.7116
Douillard JY, Oliner KS, Siena S, Tabernero J, Burkes R, Barugel M, Humblet Y, Bodoky G, Cunningham D, Jassem J, Rivera F, Kocákova I, Ruff P, Błasińska-Morawiec M, Šmakal M, Canon JL, Rother M, Williams R, Rong A, Wiezorek J, Sidhu R, Patterson SD (2013) Panitumumab-FOLFOX4 treatment and RAS mutations in colorectal cancer. N Engl J Med 369(11):1023–1034. https://doi.org/10.1056/NEJMoa1305275
Schwartzberg LS, Rivera F, Karthaus M, Fasola G, Canon JL, Hecht JR, Yu H, Oliner KS, Go WY (2014) PEAK: a randomised, multicentre phase II study of panitumumab plus modified fluouracil, leucovorin, and oxiplatin (mFOLFOX6) or bevacizumab plus FOLFOLX6 in patients with previously untreated, unresectable, wild-type KRAS exon 2 metastatic colorecatal cancer. J Clin Oncol 53:2473–2247. https://doi.org/10.1200/JCO.2013.53.2473
European Medicines Agency (2014) Erbitux (cetuximab) European Public Assessment Report. http://www.ema.europa.eu/docs/en_GB/document_library/EPAR_-_Summary_for_the_public/human/000558/WC500029111.pdf. Accessed 2 August 2018
European Medicines Agency (2017) Vectibix (panitumumab) European Public Assessment Report. http://www.ema.europa.eu/docs/en_GB/document_library/EPAR_-_Summary_for_the_public/human/000741/WC500047704.pdf. Accessed 2 August 2018
http://kras.eqascheme.org. accessed 2 August 2018
Dequeker EMC, Ligtenberg MJ, Vander Borght S, van Krieken JH (2011) Mutation analysis of KRAS prior to targeted therapy in colorectal cancer: development and evaluation of quality by a European external quality assessment scheme. Virchows Arch 459(2):155–160. https://doi.org/10.1007/s00428-011-1094-x
Tack V, Ligtenberg MJ, Tembuyser L, Normanno N, Vander Borght S, Han van Krieken JH, Dequeker EMC (2015) External quality assessment unravels interlaboratory differences in quality of RAS testing for anti-EGFR therapy in colorectal cancer. Oncologist 20(3):257–262. https://doi.org/10.1634/theoncologist.2014-0382
Cohen R, Cervera P, Svrcek M, Pellat A, Dreyer C, de Gramont A, André T (2017) BRAF-mutated colorectal Cancer: what is the optimal strategy for treatment? Curr Treat Options in Oncol 18(2):9. https://doi.org/10.1007/s11864-017-0453-5
Boleij A, Tack V, Taylor A, Kafatos G, Jenkins-Anderson S, Tembuyser L, Dequeker EMC, van Krieken JH (2016) RAS testing practices and RAS mutation prevalence among patients with metastatic colorectal cancer: results from a Europe-wide survey of pathology centres. BMC Cancer 16(1):825. https://doi.org/10.1186/s12885-016-2810-3
Dufraing K, De Hertogh G, Tack V, Keppens C, Dequeker E, van Krieken JH (2018) External quality assessment identifies training needs to determine the neoplastic cell content for biomarker testing. J Mol Diagn S1525-1578(17):30617. https://doi.org/10.1016/j.jmoldx.2018.03.003
Tack V, Ligtenberg MJL, Siebers AG, Rombout PDM, Dabir PD, Weren RDA, van Krieken JHJM, Dequeker EMC (2018) RAS testing for colorectal cancer patients is reliable in European laboratories that pass external quality assessment. Virchows Arch 472(5):717–725. https://doi.org/10.1007/s00428-017-2291-z
Plebani M, Lippi G (2016) Improving diagnosis and reducing diagnostic errors: the next frontier of laboratory medicine. Clin Chem Lab Med 54(7):1117–1118. https://doi.org/10.1515/cclm-2016-0217
International Organization for Standardization (2012) ISO 15189:2012 medical laboratories - particular requirements for quality and competence. ISO, Geneva
Clinical Laboratory Improvement Amendments of 1988, 42 U.S.C. 263a PL100–578, 1988 (2003) Laboratory Requirements, 42 C.F.R. Chapter IV, Part 493
Hammerling A (2012) Review of medical errors in laboratory diagnostics and where we are today. Lab Med 43(2):41–44. https://doi.org/10.1309/LM6ER9WJR1IHQAUY
Kloosterman A, Sjerps M, Quak A (2014) Error rates in forensic DNA analysis: definition, numbers, impact and communication. Forensic Sci Int Genet 12:77–85. https://doi.org/10.1016/j.fsigen.2014.04.014
Hawkins R (2012) Managing the pre- and post-analytical phases of the total testing process. Ann Lab Med 32(1):5–16. https://doi.org/10.3343/alm.2012.32.1.5
Keppens C, Tack V, Hart ‘t N, Tembuyser L, Ryska A, Pauwels P, Zwaenepoel K, Schuuring E, Cabillic F, Tornillo L, Warth A, Weichert W, Dequeker EMC (2018) A stitch in time saves nine: external quality assessment rounds demonstrate improved quality of biomarker analysis in lung cancer. Oncotarget 9(29):20524–20538. https://doi.org/10.18632/oncotarget.24980
International Organization for Standardization (2010) ISO 17043:2010 conformity assessment - general requirements for proficiency testing. ISO, Geneva
van Krieken JH, Normanno N, Blackhall F, Boone E, Botti G, Carneiro F, Celik I, Ciardiello F, Cree IA, Deans ZC, Edsjö A, Groenen PJTA, Kamarainen O, Kreipe HH, Ligtenberg MJL, Marchetti A, Murray S, Opdam FJM, Patterson SD, Patton S, Pinto C, Rouleau E, Schuuring E, Sterck S, Taron M, Tejpar S, Timens W, Thunnissen E, van de Ven PM, Siebers AG, Dequeker E (2013) Guideline on the requirements of external quality assessment programs in molecular pathology. Virchows Arch 462(1):27–37. https://doi.org/10.1007/s00428-012-1354-4
International Organization for Standardization (2008) ISO/TS 22367:2008 medical laboratories - reduction of error through risk management and continual improvement. ISO, Geneva
Wayne PA (2009) Clinical and Laboratory Standards Institute. Risk management techniques to identify and control laboratory error sources. Approved guideline-2nd ed. EP18-A2. https://clsi.org/media/1429/ep18a2_sample.pdf. Accessed 2 August 2018
Tack V, Schuuring E, Keppens C, ‘t Hart N, Pauwels P, Dequeker EMC, Ligtenberg M, van Krieken JH (2018) Accreditation, setting and experience as important indicators to assure quality in oncology biomarker testing laboratories. Br J Cancer 119(5):605–614. https://doi.org/10.1038/s41416-018-0204-9
Kristensen GB, Aakre KM, Kristoffersen AH, Sandberg S (2014) How to conduct external quality assessment schemes for the pre-analytical phase? Biochem Med 24(1):114–122. https://doi.org/10.11613/BM.2014.013
Tack V, Spans L, Schuuring E, Keppens C, Zwaenepoel K, Pauwels P, Van Houdt J, Dequeker E (2018) Describing the reportable range is important for reliable treatment decisions: a multi-laboratory study for molecular tumour profiling using next-generation sequencing. J Mol Diagn S1525-1578(17):30624–30753. https://doi.org/10.1016/j.jmoldx.2018.06.006
Plebani M (2015) Diagnostic errors and laboratory medicine - causes and strategies. EJIFCC 26(1):7–14
Acknowledgements
This project would not have been possible without the support of the following people: All laboratories that participated to the 2016 and 2017 ESP Colon EQA schemes, completed the survey, and/or attended the workshop, for their contribution in providing of the data. The ESP, specifically Raed Al Dieri, Lora Kostova, Sarah Byaruhanga, and Malgorzata Short for the administrative support during the schemes. Sabada Dube for the coordination of this project. The regional scheme organizers for validation and preparation of the 2016 EQA samples: Bettina Bisig, Berna Savaş, Etienne Rouleau, Gerald Höfler, Gert De Hertogh, Giancarlo Troncone, José Carlos Machado, and Karin De Stricker. Marjolijn Ligtenberg for sample validation and preparation, technical expertise, and assessment of the results. Riki Willems for sample validation and preparation. Sara Vander Borght for sample validation and assessment of the results. Véronique Tack for the coordination, assessment of results, and confirmation of laboratory settings and accreditation statuses. Lien Tembuyser for the coordination and assessment of the results. Nicola Normanno to take part as an assessor. Astrid Eijkelenboom and Paul Rombout for presenting during the workshop. Annouschka Laenen for the statistical advice.
Funding
This study was funded by a research grant from Amgen Inc., Thousand Oaks, CA 91320, USA (grant number not applicable).
Author information
Authors and Affiliations
Contributions
CK, JHVK, AGS, GK, KL, GD, and EMCD conceived and designed the study set-up. CK, KD, and EMCD collected the results in accordance with ISO17043. CK and EMCD were responsible for creation and sending of the survey, statistical analysis, and writing of the manuscript. CK, KD, JHVK, and EMCD interpreted the data. KD, JHVK, AGS, GK, KL, and GD critically revised the manuscript. JHVK and AGS were in charge of the organization and content of the workshop. GK, KL, and GD provided administrative support and sponsoring.
Corresponding author
Ethics declarations
Conflict of interest
CK, KD, AGS, and EMCD have nothing to declare. JHVK received a research grant from Amgen. GK, KL, and GD are employees and shareholders from Amgen.
Ethics
The samples originated from tissue blocks of leftover patient material obtained during routine care. Each scheme organizer signed a subcontractor agreement stating that the way in which the samples were obtained conformed to the national legal requirements for the use of patient samples. The samples were excluded from research regulations requiring informed consent.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
This article is part of the Topical Collection on Quality in Pathology
Rights and permissions
OpenAccess This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
Keppens, C., Dufraing, K., van Krieken, H.J. et al. European follow-up of incorrect biomarker results for colorectal cancer demonstrates the importance of quality improvement projects. Virchows Arch 475, 25–37 (2019). https://doi.org/10.1007/s00428-019-02525-9
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00428-019-02525-9