Introduction

The detection of the 1H NMR Mb (myoglobin) signals in vivo has presented an approach to measure intracellular oxygenation under different physiological conditions (Chung et al. 2005; Ponganis et al. 2008; Kreutzer et al. 1992). Such measurements provide insight into the role of O2 in regulating bioenergetics, especially during muscle contraction. Because these signals also appear in Hb, an opportunity exists to assess both the vascular and intracellular PO2 to clarify the regulatory interaction between metabolism and oxygen transport (Kreutzer et al. 1993; Fetler et al. 1995).

In particular, the NMR methodology depends on the protein structural transition during oxygenation and deoxygenation, which alters the intensity of the proximal histidyl NδH and γCH3Val E11 signals. Given the normalized signal intensity and the in vitro O2 association constant, experiments can determine the intracellular PO2 (Jue 1994; Kreutzer et al. 1992). For the proximal histidyl NδH, its signal intensity reaches a maximum in the fully deoxygenated state. Using the Val E11 avoids the anoxia condition, because the signal reaches a maximum intensity in the oxygenated state. Moreover, using the ratio of the proximal histidyl NδH and γCH3Val E11 signals helps discriminate signal intensity changes arising from oxygenation instead of blood volume (Kreutzer et al. 1992).

However, unlike monomeric Mb, the Val E11 signal intensity of tetrameric Hb reflects both tertiary and quaternary structural changes. Some researchers have raised concerns that the Val E11 signal intensity might not report accurately the state of Hb saturation (Fetler et al. 1995). The concern predicates on the Perutz’s interpretation of the Monod, Wyman and Changeux (MWC) two-state model of Hb oxygen binding. Only the movement of the proximal histidine links directly to the hydrogen bonding at the subunit interface as the quaternary structure shifts between the relaxed (R) to tense (T) state (Monod et al. 1965; Weissbluth 1974; Perutz 1989; Perutz et al. 1998; Bruno et al. 2001). The model does not associate specifically a T to R transition with any structural perturbation affecting the Val E11.

We have hypothesized that the R to T quaternary structural change affects similarly the signals of γCH3 Val E11 and Tyr C7, a quaternary state marker at the subunit interface. These signals will reflect accurately the state of Hb oxygenation. We have conducted a comparative spectrophotometric and NMR study of Hb with and without inositol hexaphosphate (IHP), a stable analog of the endogenous BPG (2, 3 bisphophoglycerate) allosteric effector found in erythrocytes, and at different values of pH and PO2. Indeed, the spectrophotometric and NMR assays yield oxygen-binding curves in excellent agreement with previous literature reports (Chang et al. 2002; Gong et al. 2006; Lukin and Ho 2004; Asakura and Lau 1978; Benesch et al. 1967; Rossi-Fanelli et al. 1961). As a consequence, the results confirm that 1H NMR signal of either the γCH3Val E11 or Tyr C7 responds sensitively to the structural changes in the R to T transition, reports accurately the Hb oxygenation state, and can serve as a vascular oxygen biomarker.

Materials and methods

In vitro experiment preparation

Hemoglobin was prepared as previously reported (Kreutzer et al. 1993; Wang et al. 1997). Fresh outdated red blood cells were centrifuged for 15 min at 600×g and washed three times with 1% NaCl solution. For Hb solution experiments, the erythrocytes were lysed with three volumes of distilled H2O and contaminant proteins precipitated with 20% of saturated ammonium sulfate. The lysate was centrifuged for 30 min at 10,000×g and then dialyzed against 100 mM potassium phosphate buffer (pH 7.4). Bubbling CO then converted the HbO2 to HbCO, which was stored at 4°C. Converting HbCO to HbO2 required a bright light to photodissociate CO from cold HbCO under a stream of O2.

All Hb samples used for optical and NMR studies were 0.025 or 0.125 mM in Hb tetramer in 100 mM phosphate buffer at pH 7.0. Concentration of HbO2 and deoxy Hb on a heme basis was determined by spectrophotometric measurement (UVIKON 941, Kontron Instruments) of the Hb bands. Extinction coefficients of ε 541 = 13.8 mM−1 cm−1, ε 577 = 14.6 mM−1 cm−1 and ε 555 = 12.5 mM−1 cm−1 (Antonini and Brunori 1971) were used to calculate Hb concentration. Visible spectra of the Hb samples were taken before and after the NMR experiment to measure HbO2 concentration and to detect the presence of any metHb. Only data from samples with no detectable metHb were used in the analysis.

Oxygen equilibration system

Appropriate HbO2 saturations were obtained by equilibrating Hb solution in a home-built system shown in Fig. 1. The closed loop system consists of a peristaltic pump (Cole-Parmer, Cartridge pump model: 07519-15), tubing (Pharmed, Lot No.: 201923), gas-mixing chamber with O2 permeable silastic tubing (Dow Corning, Cat.No.: 508-006), polarographic oxygen monitor (Cameron Instruments, OM2000), gas mixer (Cameron Instruments, GF-4/MP) and humidifier. The pump circulated about 40 ml of humidified HbO2 through the silastic tubing wrapped around a plastic rack, which maximized the surface area for O2 exchange, and then through an NMR tube and/or cuvette. At a flow rate of 40 ml/min, the entire solution volume passed through the system within 1 min. The gas mixer introduced a precise ratio of O2 or N2 into the gas-mixing chamber to achieve different PO2. An oxygen meter equipped with a Clark-type oxygen electrode determined the PO2 of the HbO2 solution. A spectrophotometer then measured the HbO2 signals from 450 to 650 nm with 1 nm resolution. The NMR spectrometer recorded the 1H NMR signals of Hb in the presence or absence of IHP and at identical PO2 values. A 5 μm Millipore (Millipore, Molsheim) filter removed any particulate material.

Fig. 1
figure 1

The oxygen equilibration system that permits coordinated spectrophotometric and NMR measurements: The system components comprise a peristaltic pump, gas-mixing chamber with O2 permeable tubing, a gas mixer to create different mixtures of O2 and N2, an O2 monitor, spectrophotometer or NMR spectrometer, and connecting tubings to form a closed loop. Hb injected into inlet port circulates into the gas-mixing chamber, where it equilibrates with the O2/N2 mixture defined by the gas mixer. The equilibrated Hb solution loops through either a spectrophotometer switch or an NMR spectrometer switch. For spectrophotometric assay, the Hb solution would circulate through a cuvette as the spectrophotometer records the optical spectra. For the NMR assay, the Hb solution would enter the NMR tube from the bottom and recirculate into the gas-mixing chamber. The NMR spectrometer would record the 1H NMR spectra. A typical experiment utilizes 40 ml of Hb, which circulates at 40 ml/min

Oxygen-binding curve

A spectrophotometer determined the O2-binding curves of 0.025 mM Hb in 100 mM inorganic phosphate (Pi) buffer as a function of pH (6.6–7.5) with and without IHP at 25°C. Sodium inositol hexaphosphate (IHP) was added in IHP:Hb (tetramer) molar ratio of 5:1. The addition of 0.1 N HCl or 0.1 N NaOH adjusted the pH of HbO2 as verified by a Corning (Model 240) pH meter. The spectrophotometer recorded the Hb saturation after a cycle of deoxygenation and reoxygenation at 0, 1, 1.5, 2, 3, 5, 7, 10 and 21% O2, corresponding to PO2 values between 0 and 154 mmHg. Each PO2 step required about 7 min to equilibrate with the different PO2. Two spectra were recorded for each PO2 step. A complete experiment usually required about 90 min. After the experiment, sodium dithionite was added to create the totally desaturated Hb state and the associated reference spectrum.

HbO2 fractional saturation

The fractional HbO2 saturation \( Y = {\frac{{{\text{HbO}}_{ 2} }}{{{\text{HbO}}_{ 2} + {\text{Hb}}}}} \) was determined from the absorbance change in the HbO2 β (541 nm) and α (577 nm) and the deoxy Hb (555 nm) bands. The analysis of the curve fit of Y versus PO2 with either the equation

$$ Y = {\frac{{P{\text{O}}_{ 2}^{{n_{\text{Hill}} }} }}{{P{\text{O}}_{ 2}^{{n_{\text{Hill}} }} + P_{50}^{{n_{\text{Hill}} }} }}} $$
(1)

or with the Hill equation

$$ \log {\frac{Y}{1 - Y}} = n_{\text{Hill}} \log P{\text{O}}_{ 2} $$
(2)

led to the determination of the P 50 (partial O2 pressure at 50% saturation) and the Hill coefficient, n Hill.

NMR

1H NMR experiments were performed on an Avance 400-MHz Bruker NMR spectrometer using a 20-mm microimaging probe (R31/1 20-40/MI-400-R014). A specially designed sample NMR tube was mounted inside the probe with the entrance port at the bottom and the exit port at the top. After equilibrating the Hb to a specified PO2, the Hb flowed into the probe from the bottom of the magnet and exited from the top to form a closed loop system. Typical experiment used 0.125 mM HbA in 100 mM Pi buffer at 25°C. Chemical shifts were referenced to the water proton signal at 4.75 ppm 25°C, calibrated against 2-dimethyl-2-silapentane-5-sulfonate (DSS).

The 1H NMR signals were normalized to Hb signals under fully oxygenated or deoxygenated conditions. After the NMR experiment, the relative signal intensities (integrated peak areas) of 1H NMR peaks at each oxygenation state were determined by normalizing the signal intensity to its full oxygenated and deoxygenated condition.

A 1–5–10–10–5–1 pulse sequence suppressed the water signal and produced a sufficient uniform excitation profile in the region of interest (Hore 1983). A typical HbO2 spectrum used 8 kHz spectral width, 1 K data points and 512 scans. The 90° pulse calibrated against the water proton signal was 50 μs. Zero-filling improved the spectral resolution. Apodizing the free induction decay (FID) with an exponential or an exponential-Gaussian window function improved the spectra. A spline fit then smoothed the baseline.

Statistical analysis

Statistical analysis used the Sigma Plot/Sigma Stat program (Systat Software, Inc., Point Richmond, CA) and expressed the values as mean value ± standard deviation (SD). Statistical significance was determined by two-tailed unequal variance Student’s t test with no statistical difference indicated by P > 0.05.

Results

Figure 1 shows the schematic representation of the closed loop system, which contains Hb circulating through a gas-mixing chamber, O2 monitor and an NMR tube or a spectrophotometer cuvette. A gas mixer supplies a specific mixture of N2 and O2 to the chamber, which allows the Hb solution to equilibrate at a defined PO2. A spectrophotometer monitors the changes in the Hb bands to ensure full equilibration. After the Hb has equilibrated, these bands lead to the determination of the Hb saturation. A plot of the Hb saturation as a function of PO2 yields the oxygen-binding curve. With the identical protocol, NMR can correlate the changes in the Val E11 and Tyr C7 signals, a tertiary and quaternary protein structure marker, respectively (Acharya et al. 2003; Chang et al. 2002; Dalvitt and Ho 1985; Gong et al. 2006; Lukin and Ho 2004; Viggiano et al. 1979). Table 1 tabulates the P 50 and n Hill of Hb at different pH values as determined by optical and NMR methods.

Table 1 Optical and NMR determined O2-binding parameters for Hb A

Figure 2 shows the visible spectra of 0.025 mM HbO2 in 100 mM Pi buffer pH 7.0 at 25°C with IHP (Fig. 2a) and without IHP (Fig. 2b) at PO2 between 2.6 and 155 mmHg. Keeping the temperature at 25°C ensures protein stability during the course of the experiment. The β and α bands at 541 and 577 nm fall as the PO2 decreases (Fig. 2a). In contrast, the deoxy Hb signal at 555 nm rises. Without IHP, Hb shows a sharper change in oxygen saturation (Fig. 2b). Table 2 shows the P 50 and Hill coefficient of Hb at different pH values and with or without the allosteric effector, IHP.

Fig. 2
figure 2

A representative set of optical spectra of 0.025 mM HbO2 in 100 mM Pi buffer at pH = 7.0 at 25°C a with IHP b without IHP. The oxygen equilibration system presents a defined O2 mixture to establish different Hb saturation states. The resultant Hb spectra show the changes in the β (577 nm) and α (541 nm) of HbO2, as well as the 555 nm band of deoxy Hb. Partially oxygenated samples were obtained by equilibrating Hb in a mixture of O2 and N2, starting from 0, 1, 2, 3, 5, 7, 10 to 21% O2, corresponding to PO2 between 0 and 154 mmHg. Each oxygen saturation step requires about 7 min to reach a steady state. In the IHP experiments, IHP exists in a 5:1 molar ratio of IHP:Hb

Table 2 Comparative analysis of O2-binding parameters for Hb A

The analysis of the visible spectra yields the Hb saturation (Y) as a function of PO2. Figure 3a plots Y against PO2 to produce the O2-binding curves for Hb in the presence of IHP from pH 6.6 to 7.5. The corresponding O2-binding curves in the absence of IHP show a pronounced left shift, reflecting a higher O2 affinity (Fig. 3b).

Fig. 3
figure 3

Oxygen-binding curves of HbO2 at different pH values in 100 mM Pi buffer at 25°C a with IHP b without IHP. IHP right shifts the P 50 at pH 7.0 from 13.20 to 40.75. Y is percentage of HbO2. Error bars representing standard deviation are too small to detect in the figure

Given the O2-binding curve, the analysis based on Eqs. 1 and 2 yields the pH-dependent P 50 and n Hill of Hb with and without IHP over the pH range from 6.6 to 7.5 (Fig. 4). The values of these Hb parameters stand in excellent agreement with previous literature reports (Tables 1, 2; Chang et al. 2002; Gong et al. 2006; Lukin and Ho 2004).

Fig. 4
figure 4

Plot of P 50 and n Hill of Hb A as a function of pH at 25°C with IHP and without IHP. a In the presence of IHP, P 50 decreases from 51.28 to 21.75 as pH increases from 6.6 to 7.5. Without IHP, P 50 decreases only from 17.05 to 10.98, as pH increases from 6.6 to 7.2. b HbO2 with IHP shows n Hill increasing from 2.29 to 2.77 as pH increases from 6.6 to 7.5. Without IHP, the n Hill changes from 2.85 to 2.90 as pH rises from 6.6 to 7.2

Figure 5 shows the 1H NMR spectra of the Tyr C7 peak at 14.0 and the Val E11 peak at −2.48 ppm in the presence (left panel) and absence (right panel) of IHP at PO2 values from 2.8 mmHg. The proton shared in the H-bond between α1 Tyr C7 and β2 Asp 99 in the T state gives rise to 14 ppm signal and reflects the quaternary structural change at the subunit interface during R to T transition (Ho and Russu 1981). As the quaternary state shifts from T to R with increasing PO2, the Tyr C7 signal intensity decreases. The Val E11 signal of HbO2 at −2.48 serves as a marker of Hb tertiary structure in the heme pocket. In contrast, its intensity rises as Hb saturation increases (Acharya et al. 2003; Chang et al. 2002; Dalvitt and Ho 1985; Gong et al. 2006; Lukin and Ho 2004; Viggiano et al. 1979).

Fig. 5
figure 5

1H NMR spectra of Val E11 and Tyr C7 as a function of Hb oxygenation a with IHP b without IHP. As PO2 increases, the Tyr C7 signal at 14.0 ppm falls, while the Val E11 signal at −2.48 ppm rises. The spectra show HbO2 at 0, 12.5, 25, 50, 75 and 100% oxygenation

Figure 6 overlays the measured Hb saturation at pH 7.4 and 25°C, as determined by spectrophotometry and NMR. With and without IHP, the tertiary and quaternary structural markers, as reflected in the Val E11 and Tyr C7 signals, track closely the changes in Hb saturation. Table 3 summarizes the comparison between the spectrophotometric and NMR results. At each oxygen steady state, PO2, with and without IHP, HbO2 saturation determined by optical (n = 3) and by NMR measurements (n = 4–7) shows no statistical significant difference (P > 0.05).

Fig. 6
figure 6

Plot of Hb saturation versus PO2 as determined by spectrophotometry and by the NMR signals of Val E11 and Tyr C7. The solid and dashed lines show the oxygen-binding curves of HbO2 with and without IHP. Overlaying these lines are the corresponding changes in the NMR signals of the Val E11 (filled square) and the Tyr C7 (filled circle) of Hb in the presence of IHP, and the Val E11 (open square) and the Tyr C7 (open circle) signals of Hb in the absence of IHP. Error bars represent standard deviation

Table 3 HbO2 saturation determined by spectrophotometry and NMR

Discussion

Hb oximetry

The closed loop oxygen equilibration system overcomes a major hurdle in studying the structure and function of Hb by establishing a methodological approach to determine the spectral characteristics, given a defined Hb saturation at a specified PO2, pH, allosteric modulation and temperature for both spectrophotometric and NMR experiments. The system avoids the experimental uncertainty of defining Hb saturation by mixing HbO2 with deoxy Hb (Fetler et al. 1995; Viggiano and Ho 1979). Such a mixing protocol does not always define the state of Hb saturation, because it assumes that the Hb saturation will reflect the fractional amount of HbO2 in the mixture. It does not account for the contribution from any dissolved O2 in the solution or from the action of any residual dithionite used to remove excess O2 in the deoxy Hb solution.

With the oxygen equilibration system, the spectrophotometric assay shows that the β (541 nm) and α (577 nm) bands of HbO2 decline with decreasing PO2. Conversely, the deoxy Hb signal at 555 nm increases. At present, the oximeter system can reach a PO2 of about 3 mmHg. No significant Hb degradation to metHb appears during the course of the spectrophotometry experiments. The plot of Hb saturation as a function of PO2 yields the familiar oxygen-binding curves:

At 25°C and without IHP, Hb at pH 7.2 exhibits a P 50 of 10.98 mmHg and a n Hill of 2.90. With IHP and Hb at a ratio of 5:1, the O2-binding curve right shifts as the Hb decreases its O2 affinity. Hb P 50 increases to 31.06 mmHg, while n Hill decreases to 2.52. As pH decreases from pH 7.2 to 6.6 in the absence of IHP, the P 50 also increases from 10.98 to 17.05, consistent with the acid-Bohr effect. The Hill coefficient, however, shows no change. In the presence of IHP and pH 6.6, the P 50 increases from 31.06 to 51.28 and n Hill decreases from 2.52 to 2.29.

These Hb oxygen-binding curves agree with previous literature reports and validate the oxygen equilibration system’s capacity to establish accurately the Hb saturation (Table 2; Ogata 2000; Vorger and Matelin 1985; Yonetani et al. 2002; Imai 1981). They also confirm the effectiveness of IHP, a stable analog of the endogenous allosteric effector BPG (2,3 bisphophoglycerate) in erythrocyte, to modulate the HbO2-binding affinity and cooperativity. Without IHP or BPG, Hb exhibits a high O2 affinity. Hb has a decreased efficiency in unloading O2. With the allosteric effector IHP or BPG, Hb decreases its O2 affinity. The O2-binding curve shifts to the right (Levitzki 1978). Indeed, erythrocytes increase BPG level during physiological adaptation to high altitude in order to improve O2 unloading in the capillary (Weber 2007).

Val E11 signal as a vascular PO2 biomarker

The γCH3Val E11 signal of Mb has presented an approach to measure the intracellular PO2 in isolated myocardium (Kreutzer et al. 1992). Since NMR studies have already observed the proximal histidyl NδH signals from erythrocyte, they implied the availability of the Val E11 and Tyr C7 signals as vascular PO2 biomarkers in vivo (Kreutzer et al. 1993; Tran et al. 1999). Detecting the γCH3 signal of Val E11 would immediately improve the detection sensitivity given the three-proton intensity of the CH3 group versus one-proton intensity of the proximal histidyl NδH. Moreover, it would overcome the requirement to secure a normalizing signal under anoxia, since the Val E11 signal reaches its maximal intensity under oxygenated conditions. However, its function as an oximeter must overcome the criticism that the Val E11 signal might not correspond to Hb saturation, since it does not have a direct role in propagating the quaternary structural perturbation as defined in the Perutz’s interpretation of the Monod, Changeux and Wyman (MWC) two-state model of Hb oxygen binding (Fetler et al. 1995; Monod et al. 1965; Weissbluth 1974; Perutz 1989; Perutz et al. 1998; Bruno et al. 2001).

The present study shows that the Val E11 signal does track closely Hb saturation in the presence and absence of IHP and at different pH values. As Hb saturation increases or decreases, so also does the Val E11 signal intensity. Even though the Perutz model localizes the cooperativity energy in a specific set of quaternary structural changes, it does not dismiss the presence of tertiary structural changes during the R to T transition (Perutz et al. 1968; Muirhead et al. 1967). Such tertiary structural change can still reflect the Hb oxygenation state.

Tyr C7 signal as a vascular PO2 biomarker

The correlation between the tertiary and quaternary structural changes becomes apparent in the comparative analysis of the Val E11 and Tyr C7 signals. From the NMR spectra, the Val E11 signal shows an inverse relation with the Tyr C7 signal, which originates from a T state sensitive hydrogen bond at the subunit interface. As Hb switches from the R to T state, the Perutz model specifies a hydrogen bond formation step (Ho and Russu 1981; Mihailescu and Russu 2001). In essence, the Tyr C7 peak at 14 ppm originating from a hydrogen bond at the α1β2 subunit interface reports directly on the quaternary structure of Hb (Mihailescu and Russu 2001). This unique Hb signal provides an alternative to the proximal histidyl NδH signal of deoxy Mb to assess the deoxygenated state. As Hb desaturates and undergoes the R to T transition, the Tyr C7 signal increases correspondingly.

Both the Val E11 and Tyr C7 signals track closely the Hb saturation and imply that tertiary structural perturbation of Hb, even though unlinked with the direct control of O2 affinity in the Perutz model, can still reflect the Hb saturation state. The observed correlation of both the Val E11 and Tyr C7 signals with the Hb saturation raises a question about imputing a specific localized structural change to explain fully the energetics of cooperativity (Shulman et al. 1975; Eaton et al. 1999).

Implications for in vivo vascular PO2 measurements

Assessing the vascular PO2 gradient in vivo poses many technical challenges. Yet, that measurement provides critical insight into the metabolic regulation in tissue. In the physiology field, many investigators have relied mainly on near infrared spectroscopy (NIRS) methods to assess the vascular PO2 with the NIRS signal of Hb. Both oxygenated and deoxygenated Hb have absorbances at 760 and 850 nm. However, the deoxy Hb has a sharper and more intense absorbance than oxy Hb at 760 nm. The 760 and 850 nm absorption bands form then a basis to assess the overall tissue PO2 (Jobsis 1977). Any blood volume change would affect both the oxy- and deoxy-Hb signals. By arguing that the NIRS signals originate predominantly from Hb, researchers have then presumed an exclusive measurement of the vascular PO2 (Seiyama et al. 1988; Wilson et al. 1989; Seiyama et al. 1988). Unfortunately, Mb exhibits identical spectral features. Others have presented evidence to show that the NIRS signal contains a major Mb contribution (Hoofd et al. 2009; Nioka et al. 2009; Tran et al. 1999; Ponganis et al. 2008).

The 1H NMR approach does not encounter the issue of overlapping spectra, for it can discriminate the Mb and Hb signals of the Val E11 and the proximal histidyl NδH (Kreutzer and Jue 1991; Kreutzer et al. 1992, 1993). Moreover, the Tyr C7 signal only appears in Hb. Even though some researchers have asserted that erythrocyte Hb signals do exhibit an NMR visible signal, many studies have presented experimental evidence countering such a viewpoint (Fetler et al. 1995; Ho and Russu 1981; Lindstrom and Koenig 1974; Wang et al. 1997). In fact, recent NMR experiments have detected the proximal histidyl NδH signal of deoxy Hb in human and seal skeletal muscle (Tran et al. 1999; Ponganis et al. 2008).

However, the algorithm to convert the Hb signals into vascular PO2 differs from the process to obtain the intracellular PO2 with the Mb signal. In the cell, the Mb content does not change. The proximal histidyl NδH or Val E11 peak intensity correlates directly with changes in the cellular PO2. Blood volume, however, does not remain constant and can alter the signal intensity. Both blood volume and vascular oxygenation then can alter the signal intensity of Hb. Relying only on the normalized signal intensity of the deoxy Hb histidyl NδH or Val E11 will lead to an erroneous determination. Blood volume change, however, affects both the Val E11 and the proximal histidyl NδH signal. As a consequence, using the signal intensity ratio of Val E11 and proximal histidyl NδH would overcome confounding contribution from blood volume and lead to the correct determination of the vascular PO2 (Kreutzer et al. 1992).

Even though the present study has established the feasibility of using the Val E11 or Tyr C7 signal as a biomarker of the Hb oxygenation state, the implementation of a routine NMR method to determine vascular PO2 in vivo still requires additional technical advances. These advances must address the interfering background signal arising from lipids and other endogenous molecules in the 1H NMR spectra from typical 1.5 T scanners. Moreover, they must also provide some discrimination of the compartmentalized vascular PO2 in arteries, veins and capillaries. Several studies have already begun to show some promising spectroscopic approaches (Lin et al. 2007). Nevertheless, the study has established that the Val E11 and Tyr C7 signals can report accurately the state of Hb oxygenation and will lead to new insights into the regulation of oxygen transport in tissue.

Conclusion

This study details an oxygen equilibration system that permits a comparative spectrophotometric and NMR determination of Hb saturation and which helps to address the utility of the Val E11 and the Tyr C7 as biomarkers of vascular PO2. Under different PO2, pH values and with or without IHP, the spectrophotometric assay of Hb saturation agrees with the NMR determination using the Val E11 and Tyr C7 signals. The oxygen-binding curves stand in excellent agreement with literature. Consequently, the results verify the validity of using either the Val E11 or Tyr C7 signals to assess Hb saturation and open a new direction to study vascular PO2, oxygen transport and Hb structure–function.