Abstract
Purpose
To describe the characteristics and potential differences between focal and diffuse phenotypes of untreated chronic central serous chorioretinopathy (cCSC).
Methods
For this study, patients were divided in two groups. Focal leakage was defined as 1 “hot spot” of leakage, whereas diffuse leakage was defined as either > 1 hot spot or a larger area of widespread leakage on FA. Clinical characteristics were assessed at presentation. After Bonferroni correction, P values < 0.00125 were deemed statistically significant.
Results
The focal leakage group included 68 eyes (53 males), and the diffuse leakage group included 105 eyes (88 males). Mean best-corrected visual acuity (BCVA) was 77.1 ± 8.1 Early Treatment of Diabetic Retinopathy Study (ETDRS) letters in the focal group and 76.0 ± 9.6 ETDRS letters in the diffuse group (p = 0.440). In the focal group, mean age was 46.9 ± 8.8 years, whereas this was 49.7 ± 8.3 years in the diffuse group (p = 0.033). Mean central foveal thickness was 107.1 ± 21.3 μm in the focal group and 106.2 ± 27.3 μm in the diffuse group (p = 0.818). Mean choroidal thickness was 407.5 ± 114.8 μm in the focal group and 419.1 ± 113.9 μm in the diffuse group (p = 0.578). In the focal group, subretinal fluid was present in the fellow eye in 16% of the patients, as compared to 29% in the diffuse group (p = 0.067).
Conclusions
In untreated cCSC patients with focal or diffuse leakage on FA, no marked differences in clinical characteristics were found. Extensive choroidal abnormalities may be present in both groups, which are presumed to lie at the basis of the development of cCSC.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Central serous chorioretinopathy (CSC) is a chorioretinal disease characterized by an accumulation of subretinal fluid (SRF) that often affects the macula [1,2,3]. Multimodal imaging techniques can provide a detailed assessment of the extent of retinal and choroidal abnormalities. In CSC, optical coherence tomography (OCT) is used to identify the presence of SRF, the integrity of the anatomical layers of the retina, and possible changes in these layers such as outer retinal atrophy and/or posterior cystoid retinal degeneration [4]. Parameters on SD-OCT may be helpful in predicting disease course in CSC [5].
SRF accumulation in CSC is the result of fluid leakage through a disrupted outer blood-retina barrier of the retinal pigment epithelium (RPE), while the underlying choroidal dysfunction seems to be a pivotal and probably primary abnormality in the pathogenesis of CSC. Therefore, both fluorescein angiography (FA) and indocyanine green angiography (ICGA) are valuable imaging techniques in the diagnosis, assessment of the disease activity and extent, as well as informing treatment choices in CSC [6,7,8,9]. FA can be used to detect the location, size, and number of “hot spots” of leakage and the extent of diffuse atrophic RPE alterations (DARA). ICGA can be performed to evaluate the underlying choroidal abnormalities [8, 10, 11]. Both FA and ICGA are therefore used to identify the area(s) for targeted treatment, for instance with photodynamic therapy (PDT) and high-density subthreshold micropulse laser (HSML) treatment [7, 12, 13]. In chronic CSC (cCSC), little is known about the clinical characteristics of patients with different phenotypes such as focal leakage or diffuse leakage on FA. If differences in the clinical characteristics and outcome of cCSC patients with focal leakage or diffuse leakage can be detected, this may also have prognostic and therapeutic consequences, and may give clues about potential difference in etiologies between these groups. The aim of this study is to describe the variety in abnormalities on FA and ICGA in the affected and fellow eye, to assess whether FA and ICGA abnormalities are comparable, and to compare clinical characteristics when dividing patients in groups based on focal or diffuse leakage on FA.
Materials and methods
Data from the “half-dose Photodynamic therapy versus high-density subthreshold micropulse LAser treatment in patients with chronic CEntral serous chorioretinopathy” (PLACE) trial (ClinicalTrials.gov identifier: NCT01797861) was analyzed [13, 14]. The PLACE trial was conducted from 2013 to 2016 at 5 academic medical centers, located in Leiden (the Netherlands), Nijmegen (the Netherlands), Cologne (Germany), Oxford (United Kingdom), and Paris (France). The study was performed in accordance with the tenets of the Declaration of Helsinki, and all participating centers received approval from their respective institutional review board and ethics committee. Written informed consent was obtained from all patients.
Patients who received previous CSC treatments (including oral medication such as eplerenone or spironolactone) or treatment with steroids within 3 months of screening were excluded. Additional inclusion and exclusion criteria are summarized in Table 1.
Patient demographics, BCVA in Early Treatment of Diabetic Retinopathy Study (ETDRS) letters, enhanced depth imaging (EDI) OCT, fundus autofluorescence (FAF), FA, and ICGA (Heidelberg Engineering, Heidelberg, Germany) were obtained at baseline. Eligible patients were divided in two groups, based on the leakage pattern on FA at baseline [15]. The group of patients with focal leakage had a maximum of 1 hot spot of leakage on FA. A hot spot of leakage was defined as an increase in the area of hyperfluorescence between early- and late-phase FA. Patients with diffuse leakage had either > 1 hot spot of leakage or a larger area of hyperfluorescent leakage that could not be linked with a single spot of leakage on the FA image at 3 min after the start of infusion of fluorescein. DARA was defined as hyperfluorescent abnormalities on mid-phase FA [16]. The extent of DARA was divided in three groups based on their cumulative surface: first, < 1 optic disc diameter; second, between 1 and 5 optic disc diameters; and the third group with > 5 optic disc diameters of DARA. The degree of fluorescence on mid-phase ICGA (at 10 min after the start of infusion) at the location corresponding with the hot spot on FA was categorized in intense hyperfluorescence, intermediate hyperfluorescence, or absence of hyperfluorescence [17]. Additionally, the size of the abnormalities on ICGA (< 1 optic disc diameter, 1–5 optic disc diameters, and > 5 optic disc diameters) was obtained. Patients were also categorized based on the correspondence of abnormalities on FA with findings on ICGA. The outcome of FAF imaging was categorized as either predominantly hyperautofluorescent, predominantly hypoautofluorescent, or a combination of hypo- and hyperautofluorescence, based on the degree of autofluorescence that was most common within the vascular arcades. Central foveal thickness (CFT) was defined as the distance between the inner borders of the internal limiting membrane and the inner border of the ellipsoid zone on SD-OCT [18]. Subfoveal choroidal thickness (SFCT) was defined as the distance between the outer border of the RPE layer and the inner border of the choroid-sclera junction on enhanced depth imaging SD-OCT. Both CFT and SFCT were measured with the build-in caliper in the Heidelberg OCT machine software.
For the first 30 patients, FA and ICGA imaging were independently assessed by two experienced observers (EHCvD and TJvR). When there was no consensus, a third experienced observer (CJFB) had the decisive vote. An interobserver agreement calculation was performed for these first 30 patients. Thereafter, all imaging was assessed by TJvR and discussed with the senior author (CJFB) if deemed necessary. When ambiguous, the “draw region” tool in Heidelberg was used to determine the size of the optic disc and the size of abnormalities on FA and ICGA.
Statistical analyses
The statistical analyses were performed with SPSS Statistics (IBM Corp. version 23.0. Armonk, New York, United States of America). Independent t test was used to compare continuous variables and Fisher exact tests for categorical variables between the focal leakage and diffuse leakage groups. After Bonferroni correction for 40 parameters, P values lower than 0.00125 (0.05/40) were considered to be statistically significant.
Results
In the PLACE trial, from November 2013 to September 2016, a total of 309 patients were screened for eligibility. After applying the inclusion and exclusion criteria, 141 male and 32 female patients could be included in this study. The 173 included patients had a mean age of 48.6 ± 8.6 years. The mean duration from the start of ocular complaints until baseline study visit was 7.1 ± 4.4 months. At baseline, mean BCVA was 76.4 ± 9.0 ETDRS letters, mean CFT was 106.6 ± 25.1 μm, and mean SFCT was 414.7 ± 113.9 μm.
Interobserver agreement
For the first 30 patients that were assessed, the interobserver agreement of focal versus diffuse disease on FA was 90%. Cohen’s kappa coefficient was used to assess the interobserver agreements for focal versus diffuse disease, which was found to be 0.80. The first observer (TJvR) re-assessed the imaging of the first 30 patients with regard to focal or diffuse leakage at 6 months after initial assessment. In 97% of the patients, the categorization was identical to the results of the first assessment. For DARA size on FA (smaller than 1 optic disc diameter, between 1 and 5 optic disc diameters, or larger than 5 optic disc diameters), an intraclass correlation coefficient was calculated using a two-way mixed model. There was agreement between the two observers in 87% of patients, with an intraclass correlation coefficient of 0.80.
Clinical characteristics of the focal leakage and diffuse leakage groups
Sixty-eight patients were categorized as having focal leakage (focal leakage group) and 105 patients were categorized as having diffuse leakage on FA (diffuse leakage group). There were 23 out of 68 patients (33.8%) in the focal leakage group with a previous CSC episode, and 25 out of 104 patients (24%) in the diffuse leakage group with a previous episode of CSC (in 1 patient the information was unavailable), which was not a statistically significant difference between the groups (p = 0.162). Characteristics of the patient groups with focal leakage and diffuse leakage on FA are depicted in Fig. 1. In the patients with focal leakage on FA, a mean age of 46.8 ± 8.8 years, a mean duration of symptoms until cCSC diagnosis of 7.3 ± 4.7 months, a mean BCVA of 77.1 ± 8.1 ETDRS letters, a mean CFT of 107.1 ± 21.3 μm, and a mean SFCT of 407.5 ± 114.8 μm were found. CFT could not be measured in 1 patient and SFCT could not be measured in 19 patients, due to suboptimal quality of EDI-OCT imaging. At the screening visit, patients with diffuse leakage on FA had a mean age of 49.7 ± 8.2 years, a mean duration of symptoms until cCSC diagnosis of 7.0 ± 4.2 months, a mean BCVA of 76.0 ± 9.6 ETDRS letters, a mean CFT of 106.2 ± 27.3 μm, and a mean SFCT of 419.2 ± 113.9 μm, none of which were significantly different from the focal leakage group after Bonferroni correction (p = 0.033, p = 0.704, p = 0.440, p = 0.818, p = 0.578, respectively). Because of insufficient EDI-OCT imaging quality (the scleral border could not be determined), SFCT could not be obtained in 27 patients with diffuse leakage on FA. There were no significant differences (p = 0.423) between sex at baseline between the focal leakage group (53 men, 77.9%) and diffuse leakage group (88 men, 83.8%). In the focal leakage group, there were 58 patients (85.3%) with DARA < 1 optic disc diameter, 9 patients (13.2%) with DARA 1–5 optic disc diameters, and 1 patient (1.5%) with DARA of > 5 optic disc diameters on FA. In comparison, the diffuse leakage group consisted of 60 patients (57.1%) with DARA < 1 optic disc diameter, 35 patients (33.3%) with DARA 1–5 optic disc diameters, and 10 patients (9.5%) with DARA of > 5 optic disc diameters (p < 0.001, p = 0.004, and p = 0.052, respectively, compared to the focal leakage group). In the focal leakage group, there were 56 patients (82.4%) with foveal DARA, 12 patients (17.6%) with DARA within 1 optic disc diameter from the fovea, and no patients with DARA outside the fovea, as compared to 91 patients (86.7%), 12 patients (11.4%), and 2 patients (1.9%) with these characteristics in the diffuse leakage group, respectively (p = 0.516, p = 0.269, and p = 0.519, respectively). In the focal leakage group, none of the patients had hypofluorescence on ICGA, while mild hyperfluorescence was observed in 6 patients (8.8%), and intense hyperfluorescence was seen in 62 patients (91.2%). In contrast, the diffuse leakage group consisted of 4 patients (3.8%) with hypofluorescence on ICGA, 20 patients (19.2%) with mild hyperfluorescence on ICGA (p = 0.081), and 81 patients (77.1%) with intense hyperfluorescence on ICGA (p = 0.023, compared to the focal leakage group). The areas of hyperfluorescent abnormalities on ICGA were more extensive on FA in 30 of the patients (44.1%) in the focal leakage group, whereas there were 58 patients (55.2%) in the diffuse leakage group (p = 0.161). In all other patients, the size of the area of hyperfluorescent abnormalities on FA and ICGA was comparable, with none of the patients showing a smaller area of hyperfluorescent abnormalities on ICGA as compared to FA. The autofluorescence description on FAF was predominantly hypoautofluorescent in 27 patients (39.7%), predominantly hyperautofluorescent in 17 patients (25.0%), and both hyper- and hypoautofluorescent in 24 patients (35.3%) in the focal leakage group, while this was the case in 28 patients (26.9%), 29 patients (27.9%), and 47 patients (45.2%) in the diffuse leakage group, respectively. There were no significant differences between the degree of autofluorescence on FAF in patients with predominantly hypoautofluorescence (p = 0.095), predominantly hyperautofluorescence (p = 0.727), and both hyper- and hypoautofluorescence (p = 0.209) on FAF, between the focal and diffuse leakage groups.
Characteristics of the fellow eye on multimodal imaging
The characteristics of the fellow eye for both the focal leakage and diffuse leakage group are shown in Table 2. SRF in the fellow eye was present in 11 patients (16.2%) in the focal leakage group, as compared to 30 patients (29.1%) in the diffuse leakage group (p = 0.067). In the focal leakage group, there were 33 patients (49.3%) without DARA in the fellow eye on FA, 24 patients (35.8%) with DARA < 1 optic disc diameter, 9 patients (13.4%) with DARA between 1 and 5 optic disc diameters, and 1 patient (1.5%) with DARA > 5 optic disc diameters. In comparison, the diffuse leakage group consisted of 29 patients (28.2%) without DARA in the fellow eye on FA (p = 0.009), 53 patients (51.5%) with DARA < 1 optic disc diameters (p = 0.060), 14 patients (13.6%) with DARA between 1 and 5 optic disc diameters (p > 0.999), and 7 patients (6.8%) with DARA > 5 optic disc diameters (p = 0.151). There were no statistically significant differences between the focal and diffuse leakage group regarding the FAF characteristics (Table 2).
Discussion
In this study, cCSC patients were divided into two categories, based on early-phase FA abnormalities: focal leakage was defined as a maximum of one hot spot of leakage, whereas the diffuse leakage group comprised patients with either multiple hot spots of leakage or a larger area of leakage. We hypothesized that more severe and extensive disease would be present in the diffuse leakage group, with a potentially different prognosis and treatment response outcome. In our study, abnormalities on ICGA were never smaller than on FA in all patients in both groups. Most of the patients in both groups had multifocal hyperfluorescent abnormalities on ICGA outside the area of the hotspot on FA. No significant differences in BCVA, CFT, and SFCT between the focal and diffuse leakage group were found. The fellow eye of patients with diffuse leakage on FA was more often affected by SRF, although this difference did not reach the threshold of statistical significance.
In both the focal and the diffuse leakage group, none of the patients had a smaller area of abnormalities on ICGA compared to FA, which corresponds to findings in previous studies [6, 19]. In addition, multifocal areas of hyperfluorescence on ICGA outside the zone of leakage on FA were often present in both groups. ICGA is primarily used to evaluate the status of the choroid, while FA can reveal both DARA and hot spots of fluorescein leakage [10, 20]. For CSC, this suggests that choroidal abnormalities are generally more extensive than abnormalities of the RPE. Chronic CSC may arise as chronic choroidal thickening (pachychoroid) and dysfunction, such as hyperpermeability and congestion, gradually causing RPE damage. This pachychoroid and associated choroidal dysfunction may lead only to DARA without SRF leakage, which is then compatible with pachychoroid pigment epitheliopathy, which can be regarded as the forme fruste of CSC [21]. As a complication, the RPE outer blood-retina barrier can be damaged to such a degree that SRF leaks through an RPE defect, causing active SRF leakage in CSC. Since choroidal abnormalities on ICGA extend further than those on FA, guided treatment would underestimate the extent of the underlying disease and may lead to suboptimal treatment efficacy with a higher risk of recurrences due to inadequate treatment area coverage. ICGA-guided treatment may therefore be preferable for optimal treatment efficacy [7, 13]. The observation that abnormalities on ICGA are generally at least as extensive as the RPE abnormalities on FA may also explain why PDT, which primarily targets the dysfunctional choroid, is more effective in achieving a complete resolution of SRF and leads to a better functional outcome as compared to HSML in the PLACE trial [13].
Patients with an absence of hyperfluorescent abnormalities on ICGA are less likely to respond favorably to PDT treatment [22, 23]. Despite the fact that abnormalities on ICGA are often more widespread compared to FA, strongly suggesting that choroidal changes are underlying in CSC, chronic damage to the RPE may also be of importance in the pathogenesis of SRF leakage even if choroidal hyperfluorescence and leakage become less pronounced in ICGA with time.
BCVA, CFT, and SFCT did not differ significantly between the focal and diffuse leakage groups, which may indicate that patients with diffuse leakage do not necessarily have a functionally more severe phenotype in comparison to patients with focal leakage [16]. The primary pathophysiological mechanism in CSC could thus be the same, resulting in dysfunction of the choroid and RPE, regardless of the CSC subtypes.
Despite the fact that this is the first phenotypic study on cCSC based on a large prospective multimodal imaging dataset, there are limitations to this study. The focal leakage and diffuse leakage categories that were designed for this study may be somewhat arbitrary. However, these categories were based on the results of other studies, clinical experience, and observations of two independent graders [2, 10, 15, 24].
In conclusion, abnormalities on FA appear to be of similar size or larger on ICGA, in both focal and diffuse leakage groups, which may indicate primary dysfunction of the choroid. No significant differences in BCVA, CFT, and SFCT were found between cCSC with focal versus diffuse leakage, which may suggest that the type of leakage is not necessarily associated with a big difference in functional severity of disease. Our findings also indicate that these subgroups are likely to share the same pathophysiologic background. Further studies are needed to assess if there are differences in response to treatment and long-term outcome between these cCSC subgroups.
References
Prunte C, Flammer J (1996) Choroidal capillary and venous congestion in central serous chorioretinopathy. Am J Ophthalmol 121(1):26–34
Nicholson B, Noble J, Forooghian F, Meyerle C (2013) Central serous chorioretinopathy: update on pathophysiology and treatment. Surv Ophthalmol 58(2):103–126. https://doi.org/10.1016/j.survophthal.2012.07.004
Imamura Y, Fujiwara T, Margolis R, Spaide RF (2009) Enhanced depth imaging optical coherence tomography of the choroid in central serous chorioretinopathy. Retina 29(10):1469–1473. https://doi.org/10.1097/IAE.0b013e3181be0a83
Spaide RF, Curcio CA (2011) Anatomical correlates to the bands seen in the outer retina by optical coherence tomography: literature review and model. Retina 31(8):1609–1619. https://doi.org/10.1097/IAE.0b013e3182247535
Lee H, Lee J, Chung H, Kim HC (2016) Baseline spectral domain optical coherence tomographic hyperreflective foci as a predictor of visual outcome and recurrence for central serous chorioretinopathy. Retina 36(7):1372–1380. https://doi.org/10.1097/iae.0000000000000929
Spaide RF, Hall L, Haas A, Campeas L, Yannuzzi LA, Fisher YL, Guyer DR, Slakter JS, Sorenson JA, Orlock DA (1996) Indocyanine green videoangiography of older patients with central serous chorioretinopathy. Retina 16(3):203–213
Yannuzzi LA, Slakter JS, Gross NE, Spaide RF, Costa D, Huang SJ, Klancnik JM Jr, Aizman A (2003) Indocyanine green angiography-guided photodynamic therapy for treatment of chronic central serous chorioretinopathy: a pilot study. Retina 23(3):288–298
Guyer DR, Yannuzzi LA, Slakter JS, Sorenson JA, Ho A, Orlock D (1994) Digital indocyanine green videoangiography of central serous chorioretinopathy. Arch Ophthalmol 112(8):1057–1062
Hua R, Yao K, Xia F, Li J, Guo L, Yang G, Tao J (2016) The hyper-fluorescent transitional bands in ultra-late phase of indocyanine green angiography in chronic central serous chorioretinopathy. Lasers Surg Med 48(3):260–263. https://doi.org/10.1002/lsm.22434
Cardillo Piccolino F, Borgia L, Zinicola E, Zingirian M (1995) Indocyanine green angiographic findings in central serous chorioretinopathy. Eye (Lond) 9(Pt 3):324–332. https://doi.org/10.1038/eye.1995.63
Gajdzik-Gajdecka U, Dorecka M, Nita E, Michalska A, Miniewicz-Kurowska J, Romaniuk W (2012) Indocyanine green angiography in chronic central serous chorioretinopathy. Med Sci Monit 18(2):Cr51–Cr57
Breukink MB, Mohr JK, Ossewaarde-van Norel A, den Hollander AI, Keunen JE, Hoyng CB, Boon CJ (2016) Half-dose photodynamic therapy followed by diode micropulse laser therapy as treatment for chronic central serous chorioretinopathy: evaluation of a prospective treatment protocol. Acta Ophthalmol 94(2):187–197. https://doi.org/10.1111/aos.12938
van Dijk EHC, Fauser S, Breukink MB, Blanco-Garavito R, Groenewoud JMM, Keunen JEE, Peters PJH, Dijkman G, Souied EH, MacLaren RE, Querques G, Downes SM, Hoyng CB, Boon CJF (2018) Half-dose photodynamic therapy versus high-density subthreshold micropulse laser treatment in patients with chronic central serous chorioretinopathy: the PLACE trial. Ophthalmology 125(10):1547–1555. https://doi.org/10.1016/j.ophtha.2018.04.021
Breukink MB, Downes SM, Querques G, van Dijk EHC, den Hollander AI, Blanco-Garavito R, Keunen JEE, Souied EH, MacLaren RE, Hoyng CB, Fauser S, Boon CJF (2015) Comparing half-dose photodynamic therapy with high-density subthreshold micropulse laser treatment in patients with chronic central serous chorioretinopathy (the PLACE trial): study protocol for a randomized controlled trial. Trials 16:419. https://doi.org/10.1186/s13063-015-0939-z
Chung CY, Chan YY, Li KKW (2018) Angiographic and tomographic prognostic factors of chronic central serous chorioretinopathy treated with half-dose photodynamic therapy. Ophthalmologica 240(1):37–44. https://doi.org/10.1159/000484100
Mohabati D, van Rijssen TJ, van Dijk EH, Luyten GP, Missotten TO, Hoyng CB, Yzer S, Boon CJ (2018) Clinical characteristics and long-term visual outcome of severe phenotypes of chronic central serous chorioretinopathy. Clin Ophthalmol 12:1061–1070. https://doi.org/10.2147/OPTH.S160956
Inoue R, Sawa M, Tsujikawa M, Gomi F (2010) Association between the efficacy of photodynamic therapy and indocyanine green angiography findings for central serous chorioretinopathy. Am J Ophthalmol 149(3):441–446.e441-442. https://doi.org/10.1016/j.ajo.2009.10.011
van Rijssen TJ, Mohabati D, Dijkman G, Theelen T, de Jong EK, van Dijk EHC, Boon CJF (2018) Correlation between redefined optical coherence tomography parameters and best-corrected visual acuity in non-resolving central serous chorioretinopathy treated with half-dose photodynamic therapy. PLoS One 13(8):e0202549. https://doi.org/10.1371/journal.pone.0202549
Scheider A, Nasemann JE, Lund OE (1993) Fluorescein and indocyanine green angiographies of central serous choroidopathy by scanning laser ophthalmoscopy. Am J Ophthalmol 115(1):50–56
Yannuzzi LA, Shakin JL, Fisher YL, Altomonte MA (1984) Peripheral retinal detachments and retinal pigment epithelial atrophic tracts secondary to central serous pigment epitheliopathy. Ophthalmology 91(12):1554–1572
Warrow DJ, Hoang QV, Freund KB (2013) Pachychoroid pigment epitheliopathy. Retina 33(8):1659–1672. https://doi.org/10.1097/IAE.0b013e3182953df4
van Rijssen TJ, van Dijk EHC, Dijkman G, Boon CJF (2018) Clinical characteristics of chronic central serous chorioretinopathy patients with insufficient response to reduced-settings photodynamic therapy. Graefes Arch Clin Exp Ophthalmol 256(8):1395–1402. https://doi.org/10.1007/s00417-018-4003-z
Ozkaya A, Garip R, Alkin Z, Taskapili M (2017) The comparison of multimodal imaging findings of central serous chorioretinopathy patients in regard to the early anatomically treatment response to half-fluence photodynamic therapy: a retrospective case–control study. Int J Retina Vitreous 3(1):20. https://doi.org/10.1186/s40942-017-0073-z
Daruich A, Matet A, Dirani A, Bousquet E, Zhao M, Farman N, Jaisser F, Behar-Cohen F (2015) Central serous chorioretinopathy: recent findings and new physiopathology hypothesis. Prog Retin Eye Res 48:82–118. https://doi.org/10.1016/j.preteyeres.2015.05.003
Role of funding organizations
The funding organizations had no role in the design or conduct of the study; collection, management, analysis, and interpretation of the data; preparation, review, or approval of the manuscript; and decision to submit the manuscript for publication. They provided unrestricted grants.
Funding
This research was supported by the following foundations: MaculaFonds, Retina Netherlands, BlindenPenning, and Landelijke Stichting voor Blinden en Slechtzienden, which contributed through UitZicht, as well as Rotterdamse Stichting Blindenbelangen, Haagse Stichting Blindenhulp, ZonMw VENI Grant, and Gisela Thier Fellowship of Leiden University (CJFB).
For the PLACE trial, funding was received from Novartis Pharma B.V. (Arnhem, the Netherlands) solely for the purchase of verteporfin (Visudyne) to enable photodynamic therapy treatment at the Oxford site, because photodynamic therapy currently is not reimbursed routinely by the United Kingdom National Health Service for treating central serous chorioretinopathy. Novartis Pharma B.V. had no role in funding, designing, conducting, or evaluating the study, nor in the writing of this manuscript.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Competing interests
The authors declare that they have no conflict of interest.
Ethical approval
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. This study was approved by the institutional review boards and ethical committees of each participating center.
Informed consent
Written informed consent was obtained from all individual participants included in the study. All patients were provided a means to opt out.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
van Rijssen, T.J., van Dijk, E.H.C., Scholz, P. et al. Patient characteristics of untreated chronic central serous chorioretinopathy patients with focal versus diffuse leakage. Graefes Arch Clin Exp Ophthalmol 257, 1419–1425 (2019). https://doi.org/10.1007/s00417-019-04333-y
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00417-019-04333-y