Abstract
Introduction
The choice between a cementless taper wedge stem and a fit-and-fill stem in total Hip arthroplasty (THA) for various proximal femoral morphological types has not been thoroughly evaluated. This study aimed to compare the risk of stem-related complications between these two stem types in Dorr type A, B, and C femurs.
Materials and Methods
From January 2015 through April 2021, we retrospectively reviewed 1995 cementless THA procedures. We stratified all procedures into three groups: Dorr type A (N = 360, 18.0%), B (N = 1489, 74.7%) and C (N = 146, 7.3%). The primary outcome domain was stem-related complications, including stem subsidence ≥ 3 mm, intraoperative fracture, periprosthetic fracture and aseptic stem loosening. We performed multivariate regression analysis to compare the risk of stem-related complication between the two stem types. Other factors included age, sex, body mass index, diagnosis, age-adjusted Charlson comorbidity index, stem alignment and canal fill ratio.
Results
The incidence of stem-related complications in the taper wedge and fit-and-fill stem groups was 4.4% (N = 15) and 6.5% (N = 107), respectively. Fit-and-fill stems showed an increased risk of stem-related complications (aOR: 9.903, 95% CI: 1.567–62.597) only in Dorr type C femurs. No significant difference in risk was observed in Dorr type A and B femurs. Furthermore, the canal fill ratio at the lesser trochanter, 2 cm and 7 cm below the lesser trochanter, did not exhibit an association with stem-related complications in any Dorr type.
Conclusions
Concerning the risk of stem-related complications, the taper wedge stem was a better choice in Dorr type C femurs. However, there was no difference in risk between the taper wedge stem and fit-and-fill stem in Dorr type A and B femurs.
Similar content being viewed by others
Data availability
The data of this study are available upon request from the corresponding author.
References
Dorr LD, Faugere MC, Mackel AM, Gruen TA, Bognar B, Malluche HH (1993) Structural and cellular assessment of bone quality of proximal femur. Bone 14(3):231
Wilkerson J, Fernando ND (1939) Classifications in brief: the Dorr classification of femoral bone. Clin Orthop Relat Res 478(8):2020
Khanuja HS, Vakil JJ, Goddard MS, Mont MA (2011) Cementless femoral fixation in total hip arthroplasty. J Bone Joint Surg Am 93(5):500
Gromov K, Bersang A, Nielsen CS, Kallemose T, Husted H, Troelsen A (2017) Risk factors for post-operative periprosthetic fractures following primary total hip arthroplasty with a proximally coated double-tapered cementless femoral component. Bone Joint J 99(4):451
Ishii S, Homma Y, Baba T, Ozaki Y, Matsumoto M, Kaneko K (2016) Does the canal fill ratio and femoral morphology of asian females influence early radiographic outcomes of total hip arthroplasty with an uncemented proximally coated, tapered-wedge stem? J Arthroplasty 31(7):1524
Zhao R, Cai H, Liu Y, Tian H, Zhang K, Liu Z (2017) Risk factors for intraoperative proximal femoral fracture during primary cementless THA. Orthopedics 40(2):e281
Park CW, Eun HJ, Oh SH, Kim HJ, Lim SJ, Park YS (2019) Femoral stem survivorship in Dorr type A femurs after total hip arthroplasty using a cementless tapered wedge stem: a matched comparative study with type B femurs. J Arthroplasty 34(3):527
Ikemura S, Motomura G, Hamai S, Fujii M, Kawahara S, Sato T, Hara D, Shiomoto K, Nakashima Y (2022) Tapered wedge stems decrease early postoperative subsidence following cementless total hip arthroplasty in Dorr type C femurs compared to fit-and-fill stems. J Orthop Surg Res 17(1):223
Rattanaprichavej P, Laoruengthana A, Chotanaphuti T, Khuangsirikul S, Phreethanutt C, Pongpirul K (2011) Subsidence of hydroxyapatite-coated femoral stem in Dorr type C proximal femoral morphology. J Arthroplasty 34(9):2019
Kim JT, Jeong HJ, Lee SJ, Kim HJ, Yoo JJ (2019) Does proximally coated single-wedge cementless stem work well in Dorr type C femurs? minimum 10-year followup. Indian J Orthop 53(1):94
Bornes TD, Radomski LR, Bonello JP, Mortensen-Truscott L, Safir OA, Gross AE, Kuzyk PRT (2023) Subsidence of a single-taper femoral stem in primary total hip arthroplasty: characterization, associated factors, and sequelae. J Arthroplasty 38(7S):S174
Tsai SW, Chen CF, Wu PK, Chen TH, Liu CL, Chen WM (2015) Modified anterolateral approach in minimally invasive total hip arthroplasty. Hip Int 25(3):245
Al-Najjim M, Khattak U, Sim J, Chambers I (2016) Differences in subsidence rate between alternative designs of a commonly used uncemented femoral stem. J Orthop 13(4):322
Albers A, Aoude AA, Zukor DJ, Huk OL, Antoniou J, Tanzer M (2016) Favorable results of a short, tapered, highly porous, proximally coated cementless femoral stem at a minimum 4-year follow-up. J Arthroplasty 31(4):824
Kim YH, Kim JS, Joo JH, Park JW (2012) A prospective short-term outcome study of a short metaphyseal fitting total hip arthroplasty. J Arthroplasty 27(1):88
Zhen P, Chang Y, Yue H, Chen H, Zhou S, Liu J, He X (2021) Primary total hip arthroplasty using a short bone-conserving stem in young adult osteoporotic patients with Dorr type C femoral bone. J Orthop Surg Res 16(1):17
Dalury DF, Kelley TC, Adams MJ (2012) Modern proximally tapered uncemented stems can be safely used in Dorr type C femoral bone. J Arthroplasty 27(6):1014
Zhen P, Liu J, Li X, Lu H, Zhou S (2019) Primary total hip arthroplasty using an uncemented Wagner SL stem in elderly patients with Dorr type C femoral bone. J Orthop Surg Res 14(1):377
Ma HH, Chou TA, Tsai SW, Chen CF, Wu PK, Chen WM (2021) Uncemented femoral stem design might have an impact on postoperative periprosthetic femur fracture pattern: a comparison between flat-wedge and dual-wedge stems. Injury 52(11):3461
Li M, Zeng Y, Wu Y, Liu Y, Wu L, Shen B (2022) Cementless femoral stems with lower canal fill ratio have similar mid-term to long-term outcomes to those with adequate fill ratio in Dorr type C femurs. Arch Orthop Trauma Surg 142(6):1265
Delsmann MM, Strahl A, Muhlenfeld M, Jandl NM, Beil FT, Ries C, Rolvien T (2021) High prevalence and undertreatment of osteoporosis in elderly patients undergoing total hip arthroplasty. Osteoporos Int 32(8):1661
Bottai V, Dell’Osso G, Celli F, Bugelli G, Cazzella N, Cei E, Guido G, Giannotti S (2015) Total hip replacement in osteoarthritis: the role of bone metabolism and its complications. Clin Cases Miner Bone Metab 12(3):247
Lindberg-Larsen M, Jorgensen CC, Solgaard S, Kjersgaard AG, Kehlet H, Lunbeck H, Knee R (2017) Increased risk of intraoperative and early postoperative periprosthetic femoral fracture with uncemented stems. Acta Orthop 88(4):390
Liu B, Ma W, Li H, Wu T, Huo J, Han Y (2019) Incidence, classification, and risk factors for intraoperative periprosthetic femoral fractures in patients undergoing total hip arthroplasty with a single stem: a retrospective study. J Arthroplasty 34(7):1400
Maier GS, Kolbow K, Lazovic D, Maus U (2016) The importance of bone mineral density in hip arthroplasty: results of a survey asking orthopaedic surgeons about their opinions and attitudes concerning osteoporosis and hip arthroplasty. Adv Orthop 2016:8079354
Wagner ER, Kamath AF, Fruth KM, Harmsen WS, Berry DJ (2016) Effect of body mass index on complications and reoperations after total hip arthroplasty. J Bone Joint Surg Am 98(3):169
Onggo JR, Onggo JD, de Steiger R, Hau R (2020) Greater risks of complications, infections, and revisions in the obese versus non-obese total hip arthroplasty population of 2,190,824 patients: a meta-analysis and systematic review. Osteoarthritis Cartilage 28(1):31
Jeschke E, Citak M, Gunster C, Halder AM, Heller KD, Malzahn J, Niethard FU, Schrader P, Zacher J, Gehrke T (2018) Obesity increases the risk of postoperative complications and revision rates following primary total hip arthroplasty: an analysis of 131,576 total hip arthroplasty cases. J Arthroplasty 33(7):2287
Migliorini F, Maffulli N, Pilone M, Velaj E, Hofmann UK, Bell A (2024) Demographic characteristics influencing the stem subsidence in total hip arthroplasty: an imaging study. Arch Orthop Trauma Surg 144(2):887
Stihsen C, Radl R, Keshmiri A, Rehak P, Windhager R (2012) Subsidence of a cementless femoral component influenced by body weight and body mass index. Int Orthop 36(5):941
Funding
This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Ethical standards
The ethics committee and institutional review board of Taipei Veterans General Hospital approved this study (2023–011-001BC). The requirement for informed consent was waived due to the retrospective nature of the study. The authors declare that they have no conflicts of interest.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Lee, KH., Hung, YT., Chang, CY. et al. The cementless taper wedge vs. fit-and-fill stem in primary total hip arthroplasty: risk of stem-related complication differs across Dorr types. Arch Orthop Trauma Surg (2024). https://doi.org/10.1007/s00402-024-05361-y
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s00402-024-05361-y