References
Galal S, Shin J, Principe P, Khabyeh-Hasbani N, Mehta R, Hamilton A et al (2021) STRYDE versus PRECICE magnetic internal lengthening nail for femur lengthening. Arch Orthop Trauma Surg. https://doi.org/10.1007/s00402-021-03943-8
Hvid I, Horn J, Huhnstock S, Steen H (2016) The biology of bone lengthening. J Child Orthop 10:487–492. https://doi.org/10.1007/s11832-016-0780-2
Hosny GA (2020) Limb lengthening history, evolution, complications and current concepts. J Orthop Traumatol 21:3. https://doi.org/10.1186/s10195-019-0541-3
Lee DH, Kim S, Lee JW, Park H, Kim TY, Kim HW (2017) A comparison of the device-related complications of intramedullary lengthening nails using a new classification system. Biomed Res Int 2017:8032510. https://doi.org/10.1155/2017/8032510
Frost MW, Rahbek O, Traerup J, Ceccotti AA, Kold S (2021) Systematic review of complications with externally controlled motorized intramedullary bone lengthening nails (FITBONE and PRECICE) in 983 segments. Acta Orthop 92:120–127. https://doi.org/10.1080/17453674.2020.1835321
Morrison SG, Georgiadis AG, Huser AJ, Dahl MT (2020) Complications of Limb Lengthening With Motorized Intramedullary Nails. J Am Acad Orthop Surg 28:e803–e809. https://doi.org/10.5435/JAAOS-D-20-00064
Iobst C, Frost MW, Rölfing JD, Rahbek O, Bafor A, Duncan M et al (2021) Radiographs of 366 removed limb lengthening nails reveal differences in bone abnormalities between different nail types. Bone Joint J2021:103-B(11) (in press). https://doi.org/10.1302/0301-620X.103B.BJJ-2021-0549.R1
Robbins C, Paley D (2020) Stryde Weight-bearing Internal Lengthening Nail. Tech Orthop 35:201–208. https://doi.org/10.1097/BTO.0000000000000475
NuVasive PRECICE device recall by MHRA 2021. https://www.boa.ac.uk/resources/nuvasive-precice-device-recall-by-mhra.html. Accessed 17 May 2021
Rölfing JD, Kold S, Nygaard T, Mikuzis M, Brix M, Faergemann C et al (2021) Pain, osteolysis, and periosteal reaction are associated with the STRYDE limb lengthening nail: a nationwide cross-sectional study. Acta Orthop. https://doi.org/10.1080/17453674.2021.1903278
Vogt B, Roedl R, Gosheger G, Hasselmann J, Fuest C, Toporowski G et al (2021) Focal osteolysis and corrosion at the junction of Precice Stryde intramedullary lengthening device: preliminary clinical, radiological, and metallurgic analysis of 57 lengthened segments. Bone Joint Res 10(7):425–436. https://doi.org/10.1302/2046-3758.107.BJR-2021-0146.R1
Jellesen MS, Lomholt TN, Hansen RQ, Mathiesen T, Gundlach C, Kold S et al (2021) The STRYDE limb lengthening nail is susceptible to mechanically assisted crevice corrosion: an analysis of 23 retrieved implants. Acta Orthop. https://doi.org/10.1080/17453674.2021.1927506
Iliadis AD, Wright J, Stoddart MT, Goodier WD, Calder P (2021) Early results from a single centre ’s experience with the STRYDE nail. Bone Jt J. https://doi.org/10.1302/0301-620X.103B6.BJJ-2020-2165.R1
García-Cimbrelo E, de la Curto Mano A, García-Rey E, Cordero J, Marti-Ciruelos R (2002) The intramedullary elongation nail for femoral lengthening. J Bone Joint Surg Br 84:971–977. https://doi.org/10.1302/0301-620x.84b7.12984
Guichet J-M, Deromedis B, Donnan LT, Peretti G, Lascombes P, Bado F (2003) Gradual femoral lengthening with the Albizzia intramedullary nail. J Bone Joint Surg Am 85:838–848. https://doi.org/10.2106/00004623-200305000-00011
Hasler CC, Krieg AH (2012) Current concepts of leg lengthening. J Child Orthop 6:89–104. https://doi.org/10.1007/s11832-012-0391-5
Sax OC, Conway JD, Standard SC, Assayag M, Herzenberg JE, McClure PK (2021) Risk factors for focal osteolysis in a stainless-steel limb-lengthening device. J Limb Lengthen Reconstr 7:19–25
Johnson MA, Karkenny AJ, Arkader A, Davidson RS (2021) Dissociation of a femoral intramedullary magnetic lengthening nail during routine hardware removal. JBJS Case Connect 11:1–5. https://doi.org/10.2106/JBJS.CC.20.00950
Rölfing JD, Bünger M, Petruskevicius J, Abood A (2021) Removal of broken Stryde limb lengthening nails. Orthop Traumatol Surg Res. https://doi.org/10.1016/j.otsr.2021.102958
Acknowledgements
None.
Funding
There is no funding source.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
BV: board member of GEVR.de without compensation and payment for travel, presentations and lectures by Merete Medical and Nuvasive Specialized Orthopedics, outside the submitted work; JDR: editor and board member of the Danish Society of Orthopaedics (ortopaedi.dk) and consultant for Orthofix Academy. RR: board member of kinderorthopaedie.org (VKO) without compensation and personal fees, consultant for Nuvasive Specialized Orthopedics, Smith + Nephew, Merete Medical, Kyowa Kirin and Biomarine outside the submitted work. AF: no disclosures.
Ethical approval
Not required.
Informed consent
No patients were involved; therefore, consent is not needed.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Vogt, B., Rölfing, J.D., Roedl, R. et al. Letter to the editor on “STRYDE versus PRECICE magnetic internal lengthening nail for femur lengthening”. Arch Orthop Trauma Surg 142, 3563–3564 (2022). https://doi.org/10.1007/s00402-021-04074-w
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00402-021-04074-w