Abstract
A novel rheometer based on the U-tube technique of Saunders and Ward has been developed to determine the shear moduli of very weak gels and foams. The instrument is fully automatic and operates in both static and oscillatory modes. The change of the shear modulus, with the time, was monitored in three series of samples to illustrate the performance of the instrument. The first series comprised gelatinized maize starch aqueous suspensions ranging in starch concentration from 6% to 12%. The second was a series of gelatine aqueous solutions ranging in gelatine content from 2% to 12%. The third was two commercial samples of shaving foam. The results indicated that the instrument is particularly suitable for the study of the gelation mechanism in very weak gels as well as for the study of the stability of foams in relation to time.
Similar content being viewed by others
References
Arenaz MF, Lozano JE (1998) Measurement of gelpoint temperature and modulus of pectin gels. J Food Sci 63:979–982
Atkin G, Sherman P(1980) Further applications of the modified gel rigidity modulus apparatus. J Texture Stud 10:253–259
Dahme A (1992) Gelpoint measurements on high-methoxyl pectin gels for different techniques. J Texture Stud 23:1–11
Kinkel E, Sauer EZ (1925) Angew Chem 38:413
Komatsu H, Sherman P(1974) A modified rigidity modulus technique for studying the rheological properties of w/o emulsion containing microcrystalline wax. J Texture Stud 5:97–103
Saunders PS, Ward AG(1953) An absolute method for the rigidity modulus of gelatine gel. In: Harrison VGW (ed) Proceedings of the 2nd international congress on rheology, Butterworths pp 284–290
Scott Blair GW, Burnett J (1957) An apparatus for measuring the elastic properties of very soft gels. Lab Practice 6:570–572
Scott Blair GW, Burnett J (1958) Physical changes in milk caused by the action of rennet. J Dairy Res 25:297–303
Scott Blair GW, Burnett J (1959) On the creep, recovery,relaxation and elastic “memory” of some renneted milk gels. Brit J Appl Phys 10:15–20
Stainsby G, Ring SG, Chivers GR (1984) A static method for determining the absolute shear modulus of a syneresing gel. J Texture Stud 15:23–32
Timson WJ, Kelly WD, (1966) Determination of rigidity modulus of gelatins. Photographic Sci Eng 10:278–280
Xu Z-M, Raphaelides SN, Karapantsios TD, Tellos E, Bounarelis C (2004) U-tube rheometer for the dynamic measurement of elasticity. Patent pending. European Patent application No 03386003.2. Publication bulletin. 2004/43
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Xu, Z., Raphaelides, S.N. A dynamic U-tube rheometer of novel design for the study of weak gels and foams. Rheol Acta 45, 77–82 (2005). https://doi.org/10.1007/s00397-005-0451-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00397-005-0451-6