Skip to main content

Advertisement

Log in

Simultaneous in utero assessment of AV nodal and ventricular electrophysiologic parameters in the fetal sheep heart

  • Original contribution
  • Published:
Basic Research in Cardiology Aims and scope Submit manuscript

Abstract

Background Fetal tachyarrhythmias are usually of supraventricular origin. To investigate whether specific electrophysiologic properties of the fetal heart contribute to this preponderance by either favoring supraventricular tachycardias or by rendering ventricular tachycardias unlikely, we measured fetal electrophysiologic parameters in utero using transuterine fetal transesophageal electrocardiograms in fetal sheep. Since overdrive pacing may help to establish the mechanism of an arrhythmia and may be used to treat fetal tachycardias, different modes of transesophageal pacing in utero were also assessed. Methods and results Decapolar electrophysiology catheters were fetoscopically inserted into the esophagus of 9 fetal sheep (pregnancy duration 94 – 105 days, term = 145 days). Electrocardiograms were recorded simultaneously from all adjacent bipoles and from two pacing wires sutured onto the fetal shoulders. Pacing was attempted either via two adjacent electrodes of the intraesophageal catheter or via the most distal and most proximal electrode.

Fetal cycle length, PQ, and QT intervals were close to (approx. 75 %), but fetal QRS duration was < 20 % of maternal values, thus shifting the relation between activation and repolarization towards longer excitation wave lengths. Fetal QT dispersion was small (≤ 10 ms). Atrial pacing was achieved in all fetuses using distant electrodes, and with lower thresholds when compared to closely spaced bipolar electrodes (p < 0.05). Conclusions (I) An altered relation between ventricular activation and repolarization and a low dispersion of ventricular repolarization may protect the fetal heart against ventricular reentrant tachycardias. (II) Relatively normal fetal AV nodal conduction delay already provides one of the prerequisites for supraventricular reentrant tachycardias involving the AV node at this stage of fetal development. (III) High-rate esophageal pacing of the fetal atria is best achieved using widely spaced bipolar pacing electrodes.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 26 July 2000, Returned for 1. revision: 16 August 2000, 1. Revision received: 28 November 2000, Returned for 2. revision: 18 December 2000, 2. Revision received: 23 January 2001, Accepted: 24 January 2001

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kirchhof, P., Kohl, T., Eckardt, L. et al. Simultaneous in utero assessment of AV nodal and ventricular electrophysiologic parameters in the fetal sheep heart. Basic Res Cardiol 96, 251–257 (2001). https://doi.org/10.1007/s003950170055

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s003950170055

Navigation