Abstract
Background
Previously, overall comparable outcomes were seen for balloon-expandable (BE) or self-expanding (SE) transfemoral transcatheter aortic valve replacement (TAVR). However, subgroup analyses based on large case numbers are still needed.
Methods
German national data of all BE and SE transfemoral TAVR treating aortic valve stenosis in 2019 and 2020 were analysed. We then compared different outcomes and performed a subgroup analysis for the endpoint in-hospital mortality.
Results
Overall, 46,243 TAVR were analysed, 19,910 BE, and 26,333 SE. Patients in the SE group had a significantly higher logistic EuroSCORE (13.61 vs 12.66%, p < 0.001), age (81.55 vs 79.99a, p < 0.001), and proportion of women (54.82 vs 40.06%, p < 0.001). Both groups showed a similar in-hospital mortality with 2.37% in BE and 2.35% in SE (p = 0.916). In-hospital mortality also did not differ significantly after risk adjustment (OR = 0.98 [0.86, 1.13], p = 0.799). Patients in the SE group had a significantly lower risk of major bleeding (OR = 0.83 [0.73, 0.95], p = 0.006), but a significantly higher risk of stroke (OR = 1.38 [1.19, 1.59], p < 0.001), delirium (OR = 1.15 [1.06, 1.24], p = 0.001), and permanent pacemaker implantation (OR = 1.29 [1.21, 1.37], p < 0.001). In the subgroup analysis of in-hospital mortality, there were no significant differences in any of the observed subgroups (age < 75/75–79/80–84/ ≥ 85a, logistic EuroSCORE < 4/4– < 9/ ≥ 9, gender, NYHA III/IV, previous CABG, peripheral vascular disease, COPD, pulmonary hypertension, renal disease GFR < 30 ml/min, and diabetes mellitus).
Conclusion
In the direct comparison of balloon-expandable and self-expanding TAVR, there are no differences for in-hospital mortality in subgroups.
Graphical abstract

Introduction
The question remains whether there is a difference in outcomes between balloon-expandable (BE) and self-expanding (SE) devices in transcatheter aortic valve replacement (TAVR). In a previous analysis [1], we found overall comparable results for BE as well as SE transfemoral (TF-)TAVR in Germany. In a randomized study, Thiele et al. [2] also demonstrated concordant outcomes in a subgroup analysis for the primary endpoint of all-cause mortality, stroke, moderate and severe paravalvular leakage, as well as permanent pacemaker implantation within 30 days. On the other hand, a French analysis by Deharo et al. [3] showed better results for BE TAVR, which corresponds to Van Belle et al. [4], who also saw this in a subgroup analysis for a composite endpoint of at least moderate paravalvular regurgitation and in-hospital mortality. The international CENTER study observed a lower rate of conversion to open heart surgery, stroke as well as pacemaker implantation and a higher bleeding rate in new-generation BE TAVR, but no difference in in-hospital mortality or within 30 days [5]. Subsequently, the authors also saw no difference between subgroups for mortality and stroke within one year except for valve sizes > 26 mm with lower mortality in BE TAVR [6]. In addition, regarding valve-in-valve procedures, they found lower bleeding rates within 30 days in SE TAVR, but again no difference in mortality [7].
Taking these studies together, outcomes of BE and SE TAVR appear to be overall comparable. In order to investigate this subsequently, further subgroup analyses based on large case numbers are needed. Therefore, we now compared all balloon-expandable and self-expanding transfemoral TAVR for aortic stenosis in Germany in 2019 or 2020, and formed subgroups for the endpoint in-hospital mortality.
Materials and methods
Since 2005, the German Federal Statistical Office, by means of its Research Data Centre DESTATIS, has provided the data on all patient stays in German hospitals. Those are based on inpatient hospital charges within the German DRG system. The DRG system makes use of fixed charge groups, which are formed based on diagnoses (coded according to ICD-10) respectively procedures performed (coded according to OPS).
Data on 46,243 cases of TAVR procedures performed in 2019 or 2020 were extracted from this database. As described in a previous study, patients with a baseline diagnosis of pure aortic regurgitation (principal or secondary diagnosis other than I35.0, I35.2, I06.0, I06.2) were excluded [1, 8].
In our analysis, the investigators did not have a direct access to data from individual patients. They solely had access to summary results provided by the Research Data Centre. Therefore, according to German law, ethics committee approval as well as informed consent were not required. All pooled results have been anonymized by DESTATIS. This means that any information that could be used to identify an individual patient or a single center was censored by DESTATIS to ensure privacy. In addition, the data are checked and censored by DESTATIS to prevent any conclusions being drawn about an individual center.
The analysis focused on nine differing endpoints: in-hospital mortality, major bleeding events, stroke, acute kidney injury, postoperative delirium, mechanical ventilation > 48 h, permanent pacemaker implantation, length of hospital stay, and reimbursement. Stroke as well as acute kidney injury were defined through ICD, Tenth Revision (ICD-10) codes (secondary diagnosis I63* or I64 and N17*).
Major bleeding was defined as the need for transfusion of > 5 units of red blood cells (OPS codes 8–800.c1 to 8–800.cr). In-hospital mortality, duration of mechanical ventilation, length of hospital stay, and reimbursement were part of the main DESTATIS variable set. Regarding all other comorbidities, the existing anamnestic or acute specific codes were used (OPS and ICD codes have been discussed in detail previously [1, 8]).
For the calculation of the estimated logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation), all fields could be filled in except for critical preoperative status and left ventricular function. For these, we presumed a normal status (i.e., no critical preoperative status and no left ventricular dysfunction), thus calculated a best-case scenario.
p values were calculated on the basis of Student's t tests or chi-square tests. In previous studies [1, 8], a number of baseline characteristics were identified for description of the risk profiles between the treatment groups. As there was no randomization of patients to the two observed procedural options (use of balloon-expandable or self-expanding TAVR), we applied multivariable logistic or linear regression models with use of these baseline characteristics included as potential confounders (see Table 1 for the covariates listed). Furthermore, a random intercept at center level was used to account for the correlation of error terms for patients that were treated in the same center. The results of the different regression analyses are shown in Supplementary Appendix 1. Missing values could not be imputed in this analysis as there were no codes to indicate any missing data. If the electronic health record of a patient did not contain information on a specific clinical characteristic, it was presumed to be absent. No adjustment was made for multiple testing. Hence, p values should not be interpreted as confirmatory, but are of a descriptive nature. Furthermore, inferences that are drawn from the 95% confidence intervals may not be reproducible.
Following previous approaches on the topic of subgroup analyses in aortic valve replacement [9, 10], predefined subgroups were examined for subgroup-specific treatment effects: age < 75/75–79/80–84/ ≥ 85a, logistic EuroSCORE < 4/4– < 9/ ≥ 9, gender, NYHA III/IV (New York Heart Association), previous coronary artery bypass graft (CABG), peripheral vascular disease, chronic obstructive pulmonary disease (COPD), pulmonary hypertension, renal disease with glomerular filtration rate (GFR) < 30 ml/min, and diabetes mellitus.
All analyses were performed using Stata 17 (StataCorp, College Station, Texas, USA).
Results
Baseline characteristics
Overall, 46,243 transfemoral TAVR procedures for aortic valve stenosis were performed in 2019 or 2020, with 19,910 balloon-expandable and 26,333 self-expanding valves (Table 1). Patients in the SE group had a significantly higher logistic EuroSCORE of 13.61 vs 12.66% in BE (p < 0.001), age of 81.55 vs 79.99a (p < 0.001), and proportion of women of 54.82 vs 40.06% (p < 0.001). Furthermore, there were significantly more patients in the BE group with coronary artery disease with 55.43 vs 52.57% in SE (p < 0.001), peripheral vascular disease with 10.22 vs 8.33% (p < 0.001), as well as carotid disease with 6.91 vs 5.40% (p < 0.001).
Unadjusted in-hospital outcomes of balloon-expandable or self-expanding TAVR in 2019/2020
Regarding the unadjusted in-hospital mortality (Table 2), both groups showed a similar mortality rate of 2.37% in BE and 2.35% in SE (p = 0.916). Patients treated with BE TF-TAVR had a significantly higher rate of major bleeding (2.81 vs 2.31%, p = 0.001). However, the BE group showed a lower rate of stroke (1.85 vs 2.55%, p < 0.001), delirium (7.22 vs 8.74%, p < 0.001), and permanent pacemaker implantation (12.13 vs 14.62%, p < 0.001). No difference was seen in acute kidney injury (9.49 vs 9.56%, p = 0.798) and mechanical ventilation > 48 h (2.24 vs 2.10%, p = 0.305).
Regarding resource utilization parameters, patients receiving SE TF-TAVR had a significantly shorter length of hospital stay (11.86 vs 11.61 days, p = 0.001). There was no difference in reimbursement (26,223 vs 26,131 €, p = 0.108).
Risk-adjusted in-hospital outcomes of balloon-expandable or self-expanding TAVR in 2019/2020
In-hospital mortality also did not differ significantly after risk adjustment (risk-adjusted OR = 0.98 [95% CI 0.86, 1.13], p = 0.799; Fig. 1). Patients receiving SE TF-TAVR had a significantly lower risk of major bleeding (OR = 0.83 [0.73, 0.95], p = 0.006). However, they had a significantly higher risk of stroke (OR = 1.38 [1.19, 1.59], p < 0.001), delirium (OR = 1.15 [1.06, 1.24], p = 0.001), and permanent pacemaker implantation (OR = 1.29 [1.21, 1.37], p < 0.001). There was no significant difference after risk adjustment for acute kidney injury (OR = 1.05 [0.98, 1.14], p = 0.180) and mechanical ventilation > 48 h (OR = 1.01 [0.88, 1.17], p = 0.871). Resource utilization parameters also did not differ regarding length of hospital stay (risk-adjusted Coefficient = 0.19d [− 0.01d, 0.39d], p = 0.066) and reimbursement (Coefficient = 117€ [− 22€, 257€], p = 0.099; Table 3).
Primary risk factors regarding in-hospital mortality were higher grade renal disease (GFR < 15 ml/min: OR = 2.67 [2.04, 3.50], p < 0.001; GFR < 30 ml/min: OR = 1.59 [1.24, 2.04], p < 0.001), higher grade heart failure NYHA III/IV (OR = 1.81 [1.56, 2.10], p < 0.001), and atrial fibrillation (OR = 1.43 [1.26, 1.62], p < 0.001; Supplementary Appendix 1).
Risk-adjusted subgroup analysis for the endpoint in-hospital mortality comparing balloon-expandable and self-expanding TAVR
Furthermore, we performed a subgroup analysis for the endpoint in-hospital mortality. The full regression analysis can be found in the Supplementary Appendix 2. Looking at the endpoint in-hospital mortality (Table 4, Fig. 2), there were no significant differences between SE and BE TF-TAVR in any of the subgroups: age < 75a (SE instead of BE: OR = 1.02 [0.69, 1.50], p = 0.935), 75-79a (OR = 1.20 [0.89, 1.61], p = 0.225), 80-84a (OR = 0.89 [0.72, 1.11], p = 0.294), ≥ 85a (OR = 0.90 [0.72, 1.14], p = 0.386); EuroSCORE < 4 (OR = 1.27 [0.53, 3.04], p = 0.594), 4- < 9 (OR = 0.87 [0.67, 1.12], p = 0.280), ≥ 9 (OR = 1.01 [0.86, 1.18], p = 0.941); gender (OR = 0.89 [0.74, 1.07], p = 0.204); NYHA III/IV (OR = 1.00 [0.84, 1.17], p = 0.957); previous CABG (OR = 1.49 [0.96, 2.31], p = 0.073); peripheral vascular disease (OR = 1.10 [0.78, 1.55], p = 0.588); COPD (OR = 0.99 [0.67, 1.45], p = 0.957); pulmonary hypertension (OR = 0.96 [0.74, 1.25], p = 0.779); renal disease GFR < 30 ml/min (OR = 1.32 [0.96, 1.82], p = 0.091); diabetes mellitus (OR = 1.21 [0.95, 1.54], p = 0.128).
Discussion
In our analysis of 46,243 BE and SE TF-TAVR in Germany in 2019 or 2020, we found that patients who received SE TF-TAVR had a significantly lower risk of major bleeding, but showed a significantly higher risk of stroke, delirium, and permanent pacemaker implantation. However, there were no differences for in-hospital mortality in the subgroup analysis.
In a previous study [1], we saw overall comparable results for BE as well as SE TF-TAVR in Germany in 2018. Risk of permanent pacemaker implantation differed significantly towards better results in BE TAVR. This corresponds to our current analysis. ORs for major bleeding, stroke, and delirium were not significant in the previous study. However, there were similar trends of lower bleeding rates and higher rates of stroke and delirium in SE TAVR, which were significant in our current analysis. This can be explained by the fact that we now analysed an even larger number of cases over two years instead of just one year. Length of hospital stay was significantly shorter for SE TAVR in both analyses. However, it should be noted that the overall differences are rather small. Furthermore, both analyses showed similar results for in-hospital mortality.
Consistent with our findings, the CENTER study also found lower rates of stroke and permanent pacemaker implantation as well as a higher rate of major or life-threatening bleeding in new-generation BE TAVR. However, there was no significant difference in mortality during the hospital admission or within 30 days [5], which fits our results. In addition, another analysis of the CENTER study investigated valve-in-valve TAVR and showed lower rates of major bleeding within 30 days with SE TAVR. However, the authors again saw no difference in mortality [7]. Furthermore, Habertheuer et al. [11] observed higher stroke rates within 30 days in SE TAVR, but no difference in midterm stroke rates. They also found no difference in mortality, readmission, renal failure, pacemaker implantation as well as paravalvular regurgitation within 30 days, and no difference in midterm mortality as well as readmission. In addition, Abdel-Wahab et al. [12] showed comparable clinical results for mortality, stroke, repeat hospitalization due to heart failure, myocardial infarction, bleeding events, and vascular complications for BE and SE TAVR in the German CHOICE-study in a 5-year follow-up, with lower pacemaker implantation rates in BE TAVR, but better forward-flow hemodynamics in SE valves.
Our data showed a mean permanent pacemaker implantation rate of 12.13% in BE and 14.62% in SE TAVR. Reviews in the literature have also analysed this topic. Bruno et al. [13] found values from 6.7 to 39.2% and the pooled incidence was 19%. van Rosendael et al. [14] saw mean rates between 2.3% and 36.1% for new-generation devices within a peri-procedural to 2-year follow-up, 4.0–24.0% for new-generation BE prostheses and 14.7–26.7% for SE. In addition, analyses of the German Aortic Valve Registry (GARY) revealed rates of 12.6% in BE and 19.5% in SE current-generation TAVR devices within the hospital stay [15] and 13.0–21.9% in second-generation valves at 1 year [16].
Regarding the further complications, a GARY analysis [15] revealed a lower in-hospital rate of disabling stroke of 1.1% in BE and 1.2% in SE TAVR. However, we analysed every coded stroke, not just disabling ones. In addition, the authors observed a blood transfusion rate of > 4 units of 1.4% in both BE and SE TAVR. We found rates of 2.81% in BE and 2.31% in SE TAVR requiring > 5 units. It should be noted that the data provided by DESTATIS cannot be used to distinguish whether an in-hospital complication was directly related to TAVR or whether it was a complication related to another procedure during the same hospital stay.
In our subgroup analysis comparing BE and SE TAVR for the endpoint in-hospital mortality, we did not find significant differences in any of the observed subgroups. Our data therefore suggest that, regarding the endpoint in-hospital mortality, the choice between BE or SE valves in case of a TF-TAVR can be made almost independently of the observed characteristics or pre-existing conditions of patients. The European [17] and American [18] guidelines for the management of valvular heart disease also do not specify whether BE or SE valves might be the better choice in the presence of certain patient characteristics or pre-existing conditions [7]. Other factors, such as anatomical conditions of the individual patient, may be relevant to valve selection [1, 2], as also mentioned in the American guideline [18].
Our German analysis contrasts with the French results of Van Belle et al. [4], who found better outcomes with BE TAVR in a subgroup analysis for a composite endpoint of at least moderate paravalvular regurgitation and in-hospital mortality. However, our results are consistent with the German SOLVE-TAVI trial by Thiele et al. [2], which found similar outcomes for BE and SE TAVR in a subgroup analysis for the primary endpoint consisting of all-cause mortality, stroke, moderate and severe paravalvular leakage as well as permanent pacemaker implantation within 30 days. In addition, the CENTER study also found no significant differences between the observed subgroups for mortality and stroke within one year except for valve sizes > 26 mm with a lower mortality rate in BE TAVR. The authors therefore conclude that mortality and stroke rates within one year were similar for BE as well as SE TAVR [6].
Strengths and limitations of this study are in accordance with previous analyses [1, 19,20,21,22,23]. The strength is the evaluation of complete German national data comparing all balloon-expandable and self-expanding transfemoral TAVR for aortic valve stenosis. Limitation of administrative data is possible coding error. The analysed factors depend on the coded values and for example reimbursement may influence the coding. In addition, we can only approximate Valve Academic Research Consortium 3 (VARC-3) criteria [24]. Because of the characteristics of the data, a long-term follow-up, e.g. outcomes within 1 year, cannot be performed. Finally, we cannot assure the inclusion of all relevant parameters in our study and some information—e.g. the precise valve type, anatomical conditions, pacemaker indications, causes of in-hospital mortality or a differentiation of BE and SE procedures of the same center—is not available in the data set.
Conclusions
In conclusion, we compared outcomes of 46,243 balloon-expandable and self-expanding TAVR for aortic valve stenosis in Germany in 2019 or 2020, and performed a subgroup analysis for the endpoint in-hospital mortality. Patients receiving SE TF-TAVR had a lower risk of major bleeding, but a higher risk of stroke, delirium, and permanent pacemaker implantation. However, there were no differences for in-hospital mortality in all observed subgroups.
Data availability
Data are available upon reasonable request. The patients’ data are stored on the server of the Federal Bureau of statistics and not available due to data protection. The calculated raw data are sent anonymized to the scientist.
References
Stachon P, Hehn P, Wolf D, Heidt T, Oettinger V, Zehender M et al (2021) In-hospital outcomes of self-expanding and balloon-expandable transcatheter heart valves in Germany. Clin Res Cardiol 110(12):1977–1982
Thiele H, Kurz T, Feistritzer HJ, Stachel G, Hartung P, Eitel I et al (2020) Comparison of newer generation self-expandable vs. balloon-expandable valves in transcatheter aortic valve implantation: the randomized SOLVE-TAVI trial. Eur Heart J 41(20):1890–1899
Deharo P, Bisson A, Herbert J, Lacour T, Saint Etienne C, Grammatico-Guillon L et al (2020) Impact of Sapien 3 balloon-expandable versus Evolut R self-expandable transcatheter aortic valve implantation in patients with aortic stenosis: data from a nationwide analysis. Circulation 141(4):260–268
Van Belle E, Vincent F, Labreuche J, Auffret V, Debry N, Lefèvre T et al (2020) Balloon-expandable versus self-expanding transcatheter aortic valve replacement: a propensity-matched comparison from the FRANCE-TAVI registry. Circulation 141(4):243–259
Vlastra W, Chandrasekhar J, Muñoz-Garcia AJ, Tchétché D, de Brito Jr FS, Barbanti M et al (2019) Comparison of balloon-expandable vs self-expandable valves in patients undergoing transfemoral transcatheter aortic valve implantation: from the CENTER-collaboration. Eur Heart J 40(5):456–465
van Nieuwkerk AC, Santos RB, Andraka L, Tchetche D, de Brito FS, Barbanti M et al (2021) Balloon-expandable versus self-expandable valves in transcatheter aortic valve implantation: complications and outcomes from a large international patient cohort. J Clin Med 10(17):4005
van Nieuwkerk AC, Santos RB, Fernandez-Nofrerias E, Tchetche D, de Brito Jr FS, Barbanti M et al (2022) Outcomes in Valve-in-Valve Transcatheter Aortic Valve Implantation. Am J Cardiol 172:81–89
Reinöhl J, Kaier K, Reinecke H, Schmoor C, Frankenstein L, Vach W et al (2015) Effect of availability of transcatheter aortic-valve replacement on clinical practice. N Engl J Med 373(25):2438–2447
Stachon P, Kaier K, Zirlik A, Bothe W, Heidt T, Zehender M et al (2019) Risk-Adjusted Comparison of In-Hospital Outcomes of Transcatheter and Surgical Aortic Valve Replacement. J Am Heart Assoc 8(7):e011504
Stachon P, Kaier K, Oettinger V, Bothe W, Zehender M, Bode C et al (2021) Transapical aortic valve replacement versus surgical aortic valve replacement: a subgroup analyses for at-risk populations. J Thoracic Cardiovasc Surg 162(6):1701–1709. e1
Habertheuer A, Gleason TG, Kilic A, Schindler J, Kliner D, Bianco V et al (2021) Outcomes of current-generation transfemoral balloon-expandable versus self-expandable transcatheter aortic valve replacement. Ann Thorac Surg 111(6):1968–1974
Abdel-Wahab M, Landt M, Neumann FJ, Massberg S, Frerker C, Kurz T et al (2020) 5-Year Outcomes After TAVR With Balloon-Expandable Versus Self-Expanding Valves: Results From the CHOICE Randomized Clinical Trial. JACC Cardiovasc Interv 13(9):1071–1082
Bruno F, D’Ascenzo F, Vaira MP, Elia E, Omede P, Kodali S et al (2021) Predictors of pacemaker implantation after transcatheter aortic valve implantation according to kind of prosthesis and risk profile: a systematic review and contemporary meta-analysis. Eur Heart J Qual Care Clin Outcomes 7(2):143–153
van Rosendael PJ, Delgado V, Bax JJ (2018) Pacemaker implantation rate after transcatheter aortic valve implantation with early and new-generation devices: a systematic review. Eur Heart J 39(21):2003–2013
Abdel-Wahab M, Fujita B, Frerker C, Bauer T, Beckmann A, Bekeredjian R et al (2020) Transcatheter Versus Rapid-Deployment Aortic Valve Replacement. JACC Cardiovasc Interv 13(22):2642–2654
Rudolph TK, Herrmann E, Bon D, Walther T, Bauer T, Ensminger S, et al. Comparison of contemporary transcatheter heart valve prostheses: data from the German Aortic Valve Registry (GARY).Clin Res Cardiol 2023:1–11
Vahanian A, Beyersdorf F, Praz F, Milojevic M, Baldus S, Bauersachs J et al (2022) 2021 ESC/EACTS Guidelines for the management of valvular heart disease: developed by the Task Force for the management of valvular heart disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J 43(7):561–632
Otto CM, Nishimura RA, Bonow RO, Carabello BA, Erwin JP, Gentile F et al (2021) 2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation 143(5):e72–e227
Oettinger V, Kaier K, Heidt T, Hortmann M, Wolf D, Zirlik A et al (2020) Outcomes of transcatheter aortic valve implantations in high-volume or low-volume centres in Germany. Heart 106(20):1604–1608
Kaier K, Oettinger V, Reinecke H, Schmoor C, Frankenstein L, Vach W et al (2018) Volume-outcome relationship in transcatheter aortic valve implantations in Germany 2008–2014: a secondary data analysis of electronic health records. BMJ Open 8(7):e020204
Schrage B, Becher PM, Gossling A, Savarese G, Dabboura S, Yan I et al (2021) Temporal trends in incidence, causes, use of mechanical circulatory support and mortality in cardiogenic shock. ESC Heart Fail 8(2):1295–1303
Neumann JT, Gossling A, Sorensen NA, Blankenberg S, Magnussen C, Westermann D (2020) Temporal trends in incidence and outcome of acute coronary syndrome. Clin Res Cardiol 109(9):1186–1192
Freisinger E, Fuerstenberg T, Malyar NM, Wellmann J, Keil U, Breithardt G et al (2014) German nationwide data on current trends and management of acute myocardial infarction: discrepancies between trials and real-life. Eur Heart J 35(15):979–988
Généreux P, Piazza N, Alu MC, Nazif T, Hahn RT, Pibarot P et al (2021) Valve academic research consortium 3: updated endpoint definitions for aortic valve clinical research. Eur Heart J 42(19):1825–1857
Funding
Open Access funding enabled and organized by Projekt DEAL. This work was supported by internal funding of the University Heart Center/Medical Center—University of Freiburg.
Author information
Authors and Affiliations
Contributions
VO: substantial contributions to the conception and design of the work as well as analysis and interpretation of the data, drafting the work and revising it critically for important intellectual content. IH: substantial contributions to the analysis and interpretation of data, revising the work critically for important intellectual content. DWo: substantial contributions to the analysis and interpretation of data, revising the work critically for important intellectual content. JR: substantial contributions to the analysis and interpretation of data, revising the work critically for important intellectual content. AM: substantial contributions to the analysis and interpretation of data, revising the work critically for important intellectual content. MZ: substantial contributions to the analysis and interpretation of data, revising the work critically for important intellectual content. DWe: substantial contributions to the analysis and interpretation of data, revising the work critically for important intellectual content. KK: substantial contributions to the conception and design of the work as well as acquisition and analysis and interpretation of the data, drafting the work and revising it critically for important intellectual content. CvzM: substantial contributions to the conception and design of the work as well as analysis and interpretation of the data, drafting the work and revising it critically for important intellectual content. All authors have approved the submitted version to be published and have agreed to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethics approval and informed consent
In our analysis, the investigators did not have a direct access to data from individual patients. They solely had access to summary results provided by the Research Data Centre. Therefore, according to German law, ethics committee approval and informed consent were not required. All pooled results have been anonymized by DESTATIS. This means that any information that could be used to identify an individual patient or a single center was censored by DESTATIS to ensure privacy. In addition, the data are checked and censored by DESTATIS to prevent any conclusions being drawn about an individual center.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Oettinger, V., Hilgendorf, I., Wolf, D. et al. Comparing balloon-expandable and self-expanding transfemoral transcatheter aortic valve replacement based on subgroups in Germany 2019/2020. Clin Res Cardiol (2023). https://doi.org/10.1007/s00392-023-02326-w
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s00392-023-02326-w