Experimental and theoretical assessment of the performance of Gd2O2S:Tb and La2O2S:Tb phosphors and Gd2O2S:Tb–La2O2S:Tb mixtures for X-ray imaging

  • Physics
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract.

The purpose of this work was to investigate and compare the imaging performance of Gd2O2S:Tb and La2O2S:Tb phosphors as well as of Gd2O2S:Tb and La2O2S:Tb mixtures for use in X-ray imaging detectors (intensifying screens). Phosphors were supplied in powder form and were used to prepare test screens. Three types of screens were prepared: Gd2O2S:Tb; (Gd50La50)O2S:Tb; and La2O2S:Tb. Screens were excited by X-rays with tube voltages from 40 to 120 kV and their efficiency (light intensity or light energy flux over exposure) was measured with a photomultiplier and a dosimeter. The light spectrum was also measured with a monochromator. From these measurements, the number of emitted photons per incident X-ray (NEP) and the zero frequency detective quantum efficiency (DQE(0)) of the screens were determined. Additionally, modulation transfer function (MTF) was measured by the square wave response function (SWRF) method. A theoretical model calculating NEP and DQE was also developed to fit experimental data and predict the performance of Gd2O2S:Tb–La2O2S:Tb mixtures by weight from 10–90% to 90–10%. Gd2O2S:Tb screens exhibited highest NEP, DQE, and MTF at tube voltages higher than 55 kV and lower than 45 kV, whereas La2O2S:Tb screens had better NEP, DQE, and MTF within the 45- to 55-kV range. Maximum NEP values were higher than 700 at 100–120 kV while maximum DQE(0) was 0.314 at 80 kV. Gd2O2S:Tb screens are more efficient for high X-ray tube voltage applications (e.g., abdominal imaging, chest radiography, lumbar spine radiography, CT) and for very low voltage applications (e.g., mammography). La2O2S:Tb screens are useful for medium-range X-ray voltages (e.g., pediatric radiography).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kandarakis, I., Cavouras, D. Experimental and theoretical assessment of the performance of Gd2O2S:Tb and La2O2S:Tb phosphors and Gd2O2S:Tb–La2O2S:Tb mixtures for X-ray imaging. Eur Radiol 11, 1083–1091 (2001). https://doi.org/10.1007/s003300000715

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s003300000715

Navigation