Introduction

Smaller fields of views (FOVs) in CT are generally associated with higher spatial resolution and clearer images. As the image quality becomes clearer, the ability to find lung nodules and the diagnostic ability to distinguish between benign and malignant nodules are improved [1, 2]. However, noise is increased and image quality deteriorated by reducing the FOV [3, 4]. Recently, ultra-high-resolution CT (U-HRCT) has been developed, characterized by a smaller focal size of the detector elements and the X-ray tube compared with conventional high-resolution CT (conventional HRCT), allowing clearer CT images [5]. U-HRCT with 1024 × 1024 matrix size has been reported to improve image quality and diagnostic potential [6], and that a U-HRCT matrix size of 2048 × 2048 leads to larger improvement than sizes 512 × 512 or 1024 × 1024 [7]. However, no studies investigated the influence of FOV size on image quality in U-HRCT. The spatial resolution of conventional HRCT has been reported to range from 0.23 to 0.35 mm, and that of U-HRCT to be 0.14 mm [5, 7,8,9]. One pixel of matrix size (512 × 512) corresponds to 0.156 mm (0.078 mm) when the FOV size is 80 mm (40 mm). If the pixel size at a given FOV is smaller than the spatial resolution of conventional HRCT, the image quality cannot improve even if the FOV is further decreased. Therefore, we hypothesized that even at FOV sizes for which the image quality is not further improved in conventional HRCT, an improvement could still be seen in U-HRCT. The purpose of our study was to compare the effect of FOV size on image quality in U-HRCT and conventional HRCT, so as to test such hypothesis.

Materials and methods

Cadaveric lungs

The study was approved by our Institutional Review Board and did not require informed consent due to its retrospective design. Eleven cadaveric lungs from patients with a history of pulmonary disease were used. The lungs were inflated and fixed using Heitzman’s method [10], namely distended through the main bronchus with fixative fluid containing polyethylene glycol 400, 95% ethyl alcohol, 40% formalin, and water in the proportion of 10:5:2:3. The specimens were immersed in the fixative fluid for 2 days and then air-dried.

These samples were pathologically characterized as tuberculosis (n = 2), usual interstitial pneumonia (n = 2), diffuse pan bronchiolitis, metastatic disease, cardiogenic edema, diffuse alveolar hemorrhage, diffuse alveolar damage, emphysema, and lymphangitic carcinomatosis (n = 1 each).

U-HRCT and conventional HRCT scanners

U-HRCT (Aquilion Precision™; Canon Medical Systems) and conventional HRCT (Aquilion ONE™; Canon Medical Systems) were used as CT scanners. In U-HRCT, the detector element size is 0.25 × 0.25 mm, with 160 rows and 1792 channels, and the focus size of the X-ray tube is 0.4 × 0.5 mm. On the other hand, in conventional HRCT, the detector element size is 0.5 × 0.5 mm, with 320 rows and 896 channels, and the focus size of the X-ray tube is 0.8 × 0.9 mm. The detector size of the U-HRCT scanner is thus half the size of the conventional CT detector elements in both the xy plane and the z-axis direction, and the focus size of the X-ray tube in U-HRCT is approximately 1/3 that of conventional HRCT.

Image acquisition

The lungs were scanned with U-HRCT and conventional HRCT. U-HRCT images were obtained with a gantry rotation of 1.5 s, pitch factor 0.81, 120 kV, 200 mA, and CT dose index 23.2 mGy. Conventional HRCT images were obtained with a gantry rotation of 1.5 s, pitch factor 0.81, 120 kV, 200 mA, and CT dose index 23.9 mGy. Each lung was scanned at three different position levels. CT images with slice thickness 0.5 mm were reconstructed using the following FOV sizes: 40, 80, 160, 240, and 320 mm. The images were reconstructed at a 512 × 512 matrix size. FC81 was used as the reconstruction kernel (Figs. 1 and 2). In total, we obtained 330 images (66 per each FOV size).

Fig. 1
figure 1

Images of conventional HRCT of cadaveric lung (usual interstitial pneumonia) at FOV 40 mm (a), 80 mm (b), 160 mm (c), 240 mm (d), and 320 mm (e). Sharpness of bronchi walls (arrowhead) and overall image quality were improved as the FOV was reduced from 320 to 240 or 160 mm. However, when the FOV was reduced from 160 to 80 or 40 mm, sharpness of bronchi walls (arrowhead) and overall image quality improved only slightly or were essentially unchanged

Fig. 2
figure 2

Images of U-HRCT of cadaveric lung (usual interstitial pneumonia) at FOV 40 mm (a), 80 mm (b), 160 mm (c), 240 mm (d), and 320 mm (e). Sharpness of bronchi walls (arrowhead) and overall image quality were improved as the FOV was reduced from 320 to 240, 160, or 80 mm. However, when the FOV was reduced from 80 to 40 mm, sharpness of bronchi walls (arrowhead) and overall image improved only slightly

Evaluation of image quality

To clarify the influence of FOV in conventional HRCT and U-HRCT, three image quality evaluations were performed. In the first evaluation, conventional HRCT image quality was compared among the FOV values. In the second evaluation, the same comparison was performed using the U-HRCT images. In the third evaluation, the image quality of conventional HRCT was compared with that of U-HRCT. Image quality was evaluated using an 8.3-megapixel, 32-in. color liquid crystal display monitor.

Evaluation of conventional HRCT image quality

In the first evaluation, we compared the image quality with conventional HRCT among the FOVs (40, 80, 160, 240, and 320 mm) in the following items: bronchi (n = 66), small vessel (n = 66), bronchiectasis (n = 6), bronchovascular bundle thickening (n = 4), consolidation (n = 4), emphysema (n = 5), faint nodules (n = 9), ground-glass opacity (n = 6), honeycombing (n = 9), interlobular septal thickening (n = 7), reticulation (n = 6), and solid nodules (n = 14). These items were marked in advance to obtain uniform evaluation points. Overall image quality (n = 66) was evaluated on the whole image. An image was randomly selected from the five FOVs and evaluated with respect to the image with FOV 160 mm at the same level, independently by three radiologists (with 8, 17, and 25 years of experience) on a 5-point scale. The images were presented in random order and the evaluators were blinded to the next image to be presented.

The scoring scale was defined in comparison to the reference image as follows: score 1, obviously poor image quality (almost impossible to detect structures or very difficult to clearly evaluate their margin or internal characteristics); score 2, poor image quality (possible to detect structures but difficult to clearly evaluate their margin or internal characteristics); score 3, fair image quality (margin or internal characteristics can be detected and evaluated as well as in the reference image); score 4, better image quality (easier to detect structures and to evaluate their margin or internal characteristics); and score 5, excellent image quality (significantly easier to detect structures and to evaluate their margin or internal characteristics, without any indistinct findings).

Evaluation of U-HRCT image quality

In the second evaluation, the same comparisons were performed on U-HRCT images, using the same 5-point scale, by the same three radiologists in a blinded manner.

Comparison of conventional HRCT and U-HRCT

In the third evaluation, we selected one image obtained with conventional HRCT and the U-HRCT image of the same case, at the same FOV and slice level, and evaluated overall image quality. The two images were displayed side by side, with random assignment of the side and the order of image presentation. The image presented on the right side was evaluated with reference to the image presented on the left side. Overall image quality was evaluated on the whole image. The scoring was independently performed by three radiologists in comparison with the reference image using a 3-point scale: score 1, poor image quality (possible to detect structures but difficult to clearly evaluate their margin or internal characteristics); score 2, fair image quality (margin or internal characteristics can be detected and evaluated as well as in the reference image); and score 3, excellent image quality (easier to detect structures and to evaluate their margin or internal characteristics, without any indistinct findings).

Quantitative evaluation of noise

Image noise was quantitatively obtained using the workstation by measuring the standard deviation (SD) values of circular regions of interest (ROI), which were drawn on the air portion of images. We used the same monitor as in the abovementioned evaluations. It has been reported that noise can be quantitatively evaluated by measuring the SD value with an ROI in the air portion [11,12,13]. Images for which ROIs could be drawn with all FOVs were extracted, and one to three ROIs of the same size were placed at the same location on the selected conventional HRCT image and the U-HRTC image. The SD value was calculated in cases with one ROI, and the average SD in cases with multiple ROIs.

Statistical analysis

In the first and second evaluation, the median values of the subjective scores of the three radiologists and the statistical significance of the differences among FOVs were analyzed using Shapiro–Wilk test to test normality and ANOVA with Bonferroni post hoc test. P values < 0.005 were considered significant. In the third evaluation, the median values of the subjective scores of the three radiologists and the statistical significance of the differences between conventional HRCT and U-HRCT at the same FOV were analyzed using Shapiro–Wilk test to test normality and two-way ANOVA with Bonferroni post hoc test. P values < 0.05 were considered significant. In the quantitative noise evaluation, two-way ANOVA and Bonferroni post hoc test were used to compare the various FOVs in each CT model (p < 0.005 considered significant) and the CT models at each FOV (p < 0.05 considered significant). In all evaluations, the results of normality test were nonparametric. SPSS (version 24; IBM) was used for statistical processing.

Results

Evaluation of conventional HRCT image quality

The scores (FOV 40, 80, 160, 240, and 320 mm) and the results of the comparisons between FOVs (40 vs. 80 mm, 40 vs. 160 mm, and 80 vs. 160 mm) are summarized in Table 1, while the results of the other comparisons are summarized in Supplemental Table 1 (F > 27.2, p < 0.001 in all ANOVA comparisons).

Table 1 Subjective evaluation of conventional HRCT: CT findings

Overall image quality scores clearly improved as the FOV was reduced from 320 to 240 or 160 mm (all p < 0.001). However, when the FOV was reduced from 160 to 80 mm, the score was not significantly different, and a further reduction from 80 to 40 mm led to a slight improvement (p = 0.002).

Likewise, the scores of all the evaluation items clearly improved as the FOV was reduced from 320 to 160 mm (p < 0.001). When the FOV was reduced from 160 to 80 or 40 mm, the scores improved only slightly (p < 0.001) or showed no significant differences.

Evaluation of U-HRCT image quality

The scores for each FOV and the results of the comparison between the FOVs are summarized in Table 2, while the results of the other comparisons are shown in Supplemental Table 2 (F > 80.8, p < 0.001 in all ANOVA comparisons).

Table 2 Subjective evaluation of U-HRCT: CT findings

The overall image quality scores clearly improved as the FOV was reduced from 320 to 240, 160, or 80 mm (p < 0.001). When the FOV was reduced from 80 to 40 mm, the score improved slightly (p < 0.001).

Similarly, the scores of all the evaluations clearly improved as the FOV was reduced from 320 to 80 mm (p < 0.001). However, when the FOV was further reduced from 80 to 40 mm, the scores slightly improved (p < 0.001) or showed no significant differences.

Comparison of conventional HRCT and U-HRCT

The results are summarized in Table 3 (two-way ANOVA for the comparison among FOV sizes: F = 0.041, p = 0.997; two-way ANOVA analyzing CT model, FOV size, and their interaction: F > 5.6, p < 0.001). The U-HRCT overall image quality scores were superior to those of conventional HRCT at all FOVs (all p < 0.001, Figs. 3 and 4). A significant interaction between FOV size and CT model (p < 0.001) and a significant main effect of CT model (p < 0.001), but not of FOV (p = 0.997), were detected.

Table 3 Subjective comparison of U-HRCT and conventional HRCT: CT findings
Fig. 3
figure 3

Images of conventional HRCT (a, c) and U-HRCT (b, d) of cadaveric lung (usual interstitial pneumonia) at FOV 40 mm. Overall image quality of U-HRCT was improved compared with conventional HRCT and noise was more severe in U-HRCT compared with conventional HRCT

Fig. 4
figure 4

Images of conventional HRCT (a, c) and U-HRCT (b, d) of cadaveric lung (usual interstitial pneumonia) at FOV 320 mm. Overall image quality was improved in U-HRCT compared with conventional HRCT and no difference in noise was detected

Quantitative evaluation of noise

The results are summarized in Table 4 (two-way ANOVA including FOV size, CT model, and their interaction: F > 235, p < 0.001). In conventional HRCT, there were significant differences between all pairs of FOVs (p < 0.001), except between 40 and 80 mm (p = 0.13). In U-HRCT, there were significant differences between all pairs of FOVs (p < 0.001). When comparing conventional HRCT with U-HRCT at each FOV, there were significant differences at FOV 40, 80, and 160 mm (p < 0.001), but not at 240 and 320 mm (p = 0.12 and p = 0.13, respectively). A significant interaction between FOV size and CT model was detected (p < 0.001), as well as significant main effects of both FOV size and CT model (both p < 0.001).

Table 4 Quantitative evaluation of noise on conventional HRCT and U-HRCT: SD value

Discussion

Conventional HRCT image quality showed significant improvements when the FOV was reduced to 160 mm, but further FOV reduction led to slight or nonsignificant improvements. Similar results were obtained for U-HRCT; however, significant improvements could be observed when the FOV was reduced to 80 mm. Comparing U-HRCT and conventional HRCT, the U-HRCT overall image quality scores were superior to those of conventional HRCT at all FOVs. The image noise of U-HRCT, but not conventional HRCT, was increased when the FOV was reduced from 80 to 40 mm.

The spatial resolution of conventional HRCT is in the range of 0.23–0.35 mm [5, 9, 10]. When using a 512 × 512 matrix size, the size of one pixel at FOV 160 mm (80 mm) is 0.313 mm (0.156 mm). Therefore, the spatial resolution of conventional HRCT is higher than the pixel size at FOV 160 mm and lower at FOV 80 mm. These considerations are relevant to the quantitative evaluation of noise. It has been reported that image quality is improved and the noise is enhanced at higher resolution [3, 4]. We can conclude that in conventional HRCT improvements in image quality cannot be expected, and noise would not significantly increase, when the FOV is reduced from 80 to 40 mm, because the pixel size becomes smaller than the resolution. In U-HRCT, the spatial resolution is 0.14 mm [5, 7,8,9]. When using a 512 × 512 matrix size, the pixel size at FOV 40 mm is 0.078 mm. Therefore, the spatial resolution of U-HRCT is higher (lower) than the pixel size at FOV 80 mm (40 mm). Therefore, improvements in U-HRCT image quality can be expected as the FOV is reduced to 80 mm, because the resolution of U-HRCT is still higher than the pixel size, and the same applies to image noise. The quantitative evaluation of noise showed a synergic effect of FOV size and CT model, and both factors affected image noise independently. In particular, U-HRCT noise becomes more severe compared with conventional HRCT when the FOV is reduced. At FOV 240 and 320 mm, noise is almost equal in U-HRCT and HRCT, suggesting that the noise increase associated with U-HRCT might not affect clinical practice, where these or larger FOVs are frequently used.

Therefore, the use of U-HRCT allows clearer diagnostic images compared with conventional HRCT, without increasing noise. A study reported that in U-HRCT, minute structures such as bronchi were clearly delineated, and noise was reduced, in comparison with conventional HRCT [14]. It was also reported that images acquired using U-HRCT with a 0.25-mm slice thickness showed improved performance compared with a 0.5-mm thickness in visualizing the Adamkiewicz artery [15] and allowed visualizing calcified lesions of the coronary artery with fewer artifacts [16]. These reports support the results of our study. Regarding structures such as nodules, the average interslice volume was reported to be reduced, and small nodule detection improved, by using thin sections [17].

Image quality affects the quantitative and qualitative evaluation of lung field lesions [18, 19]. Improvement in image quality in the lung field plays an important role in diagnosis. Studies reported that U-HRCT can improve nodule images in the lung or bronchi, thereby improving diagnostic confidence [6, 20]. It was also reported that when using U-HRCT with a small FOV (100 mm), the lung nodule image quality and diagnostic confidence were improved compared with conventional HRCT with a larger FOV (350 mm) [18]. In summary, U-HRCT can be expected to improve the quality of diagnostic imaging of the lung and reduce the noise in clinical practice by allowing reduced FOVs.

This study has some limitations. Cadaveric lungs were used, and we did not evaluate the effects of absorption and scattering in the thorax on image quality. Moreover, image evaluation using cadaveric lungs does not include respiratory variation or fluctuations of the chest wall. Thus, image acquisition in this study does not necessarily correspond to actual clinical practice, making unclear to what extent our results can be applied to clinical practice; it will be necessary to study the influence of these fluctuations on U-HRCT image quality. Moreover, the sample size was relatively small. Regarding the evaluation procedure, the radiologists who evaluated the various items may have been unconsciously influenced by other information such as noise. Thus, it is possible that the evaluations of the different items were not completely independent. The side-by-side comparison used to evaluate conventional HRCT and U-HRCT may bias the radiologist’s evaluation. Only Canon CT scanners were used in the study, and therefore, strictly speaking, the results can be applied to U-HRCT developed by Canon Medical Systems, and it is unknown whether the same results would apply to U-HRCT developed by other companies. Despite our best efforts to match the slice position, the match was not perfect, so that the slice positions of the evaluation image and the reference image were slightly different, and such slight difference in slice position may have affected the image quality evaluation. It was reported that the FC81 reconstruction kernel performs different processes between conventional HRCT and U-HRCT [14], and such difference in reconstruction may affect image quality. We used pathologically diagnosed cadaveric lungs to our study, but we did not correlate abnormal CT findings such as solid nodules with the pathological assessments. The cadaveric lungs were inflated and fixed using the Heitzman’s method, and we do not know in detail the effects of such procedure on lung tissue, which could in principle affect both pathological diagnosis and image evaluation. However, the conventional HRCT and U-HRCT images were acquired almost at the same time, so that there was no difference in the quality of the cadaveric lungs between conventional HRCT and U-HRCT. A method to evaluate image quality by measuring tumor SNR has been reported [21], but SNR was not measured in this study. Because some evaluation items were not uniform (such as honeycombing, reticulation, etc.), unlike in tumors, when setting ROIs, the signal varied with the evaluation items, leading to instability of the quantitative evaluation.

In conclusion, since the spatial resolution of U-HRCT is higher than that of conventional HRCT, the limit of FOV at which image quality improves with conventional HRCT is 160 mm, while with U-HRCT image quality improves even when the FOV is reduced to 80 mm. Moreover, at all FOVs, U-HRCT image quality is improved compared with conventional HRCT. Thus, improvement of clinical diagnostic performance may be expected using U-HRCT, although further clinical studies will be needed.