Abstract
The purpose of this study was to compare performance of small intestinal submucosa (SIS)-covered endografts (SCEs) to polytetra-fluoroethylene (PTFE)-covered endografts (PCEs) and to bare nitinol stents (BSs) in injured sheep femoral artery (FA). Bare Zilver 6 mm × 40 mm nitinol stents (n = 6), Zilver stents covered with SIS (n = 6), and Palmaz stents 6 mm × 37 mm covered with PTFE (n = 6) were implanted in the balloon-injured FAs of nine female sheep. Follow-up arteriograms were obtained before animal sacrifice at 1, 3 and 6 months, with three animals at each time point. The FAs with the implanted device were explanted for histologic studies and morphologic measurements. Stent implantation was technically successful in all sheep. All BS and SCEs were patent at each time point. Five BSs and five SCEs exhibited formation of progressive eccentric intimal hyperplasia (IH) that was more advanced in SCE at 6 months. Cross-sectional area narrowing averaged 60% for BSs and 67% for SCEs. One BS, one SCE and two patent PCEs exhibited mild-to-moderate formation of concentric IH. Four PCS occluded one at 1 month, two at 3 months and one at 6 months. Performance of the devices placed into sheep FAs depended on their relation to the curving peri-articular portion of the FA during extremity flexion. BSs and SCEs placed in this portion exhibited progressive growth of eccentric IH while PCEs placed in this portion occluded.
Similar content being viewed by others
References
SF Badylak GC Lantz AC Coffey LA Geddes (1989) ArticleTitleSmall intestinal submucosa as a large diameter vascular graft in the dog J Surg Res 47 74–80 Occurrence Handle10.1016/0022-4804(89)90050-4 Occurrence Handle1:STN:280:BiaB1Mvlsl0%3D Occurrence Handle2739401
GC Lantz SF Badylak MC Hiles AC Coffey LA Geddes K Kokini GE Sandusky RJ Morff (1993) ArticleTitleSmall intestinal submucosa as a vascular graft: a review J Invest Surg 6 297–310 Occurrence Handle1:STN:280:ByuD3c7ot1M%3D Occurrence Handle8399001
SF Badylak AC Coffey GC Lantz WA Tacker LA Geddes (1994) ArticleTitleComparison of the resistance to infection of intestinal submucosa arterial auto grafts versus polytetrafluoroethylene arterial prostheses in a dog model J Vasc Surg 19 465–472 Occurrence Handle1:STN:280:ByuC2s3nslc%3D Occurrence Handle8126859
MC Hiles SF Badylak GC Lantz K Kokini LA Geddes RJ Morf (1995) ArticleTitleMechanical properties of xenogenic small-intestinal submucosa when used as an aortic graft in the dog J Biomed Mater Res 29 883–895 Occurrence Handle1:CAS:528:DyaK2MXms1WlsLY%3D Occurrence Handle7593028
D Pavcnik B Uchida HA Timmermans C Corless FS Keller J Rösch (2000) ArticleTitleSquare stent-based large vessel occluder JVIR 11 1227–1234 Occurrence Handle1:STN:280:DC%2BD3cvptVaisw%3D%3D Occurrence Handle11041484
D Pavcnik BT Uchida FS Keller C Corless J Rösch (2000) ArticleTitleAortic and venous valve for percutaneous placement Min Invas Ther Allied Technol 9(3/4) 287–292
K Yamada D Pavcnik BT Uchida HA Timmermans C Corless Q Yin K Yamakado JW Park FS Keller J Rösch M Sato R Yamada (2001) ArticleTitleEndoluminal treatment of ruptured abdominal aortic aneurysm with small intestinal submucosa sandwich endografts: a pilot study in sheep Cardiovasc Intervent Radiol 24 99–105 Occurrence Handle10.1007/s002700000400 Occurrence Handle1:STN:280:DC%2BD3MzoslemtQ%3D%3D Occurrence Handle11443394
D Pavcnik B Uchida HA Timmermans FS Keller J Rösch (2001) ArticleTitleSquare stent: a new self-expandable endoluminal device and its applications Cardiovasc Intervent Radiol 24 207–217 Occurrence Handle10.1007/s00270-001-0041-7 Occurrence Handle1:STN:280:DC%2BD38%2Flt1CgsA%3D%3D Occurrence Handle11779008
D Pavcnik BT Uchida HA Timmermans C Corless M O’Hara N Toyota GL Moneta FS Keller J Rösch (2002) ArticleTitlePercutaneous bioprosthetic venous valve: a long- term study in sheep J Vasc Surg 35 598–602 Occurrence Handle10.1067/mva.2002.118825 Occurrence Handle11877716
N Toyota D Pavcnik W VanAlstine BT Uchida HA Timmermans Q Yin JA Kaufman K Ito FS Keller J Rösch (2002) ArticleTitleComparison of small intestinal submucosa- covered and noncovered nitinol stents in the sheep iliac arteries: a pilot study J Vasc Interv Radiol 13 489–498 Occurrence Handle11997357
Getty R. (1975) Sisson and Grossman’s The anatomy of the domestic animals. WB Saunders, pp 994–995
J Marin F Veith J Cynamon RE Parsons RT Lyon WD Suggs CW Bakal S Waahl LA Sanchez JG Yuan T Ohki (1996) ArticleTitleEffect of polytetra-fluoroethylene covering of Palmaz stents on the development of intimal hyperplasia in human iliac arteries J Vasc Interv Radiol 7 651–656 Occurrence Handle1:STN:280:ByiD2M3mvFc%3D Occurrence Handle8897327
PG Anderson (1992) ArticleTitleRestenosis: animal models and morphometric techniques in studies of the vascular response to injury Cardiovasc Pathol 1 263–278 Occurrence Handle10.1016/1054-8807(92)90037-O
RS Schwartz KC Huber JG Murphy WD Edwards AR Camrud RE Vliestra DR Holmes (1992) ArticleTitleRestenosis and the proportional neointimal response to coronary artery injury: results in a porcine model J Am Coll Cardiol 19 267–274 Occurrence Handle1:STN:280:By2C387ls1A%3D Occurrence Handle1732351
R Kornowski MK Hong FO Tio O Bramwell H Wu MB Leon (1998) ArticleTitleIn-stent restenosis: contributions of inflammatory responses and arterial injury to neointimal hyperplasia J Am Coll Cardiol 31 224–230 Occurrence Handle10.1016/S0735-1097(97)00450-6 Occurrence Handle1:STN:280:DyaK1c%2Fos1SisQ%3D%3D Occurrence Handle9426044
RT Andrews AC Venbrux CA Magee DA Bova (1999) ArticleTitlePlacement of a flexible endovascular stent across the femoral joint: an in vivo study in the swine model J Vasc Interv Radiol 10 1219–1228 Occurrence Handle1:STN:280:DyaK1MvlsVehsQ%3D%3D Occurrence Handle10527199
KH Barth R Virmani J Froelich T Takeda SV Lossef J Newsome R Jones D Lindisch (1996) ArticleTitlePaired comparison of vascular wall reactions to Palmaz stents, Strecker tantalum stents, and Wallstents in canine iliac and femoral arteries Circulation 93 2161–2169 Occurrence Handle1:STN:280:BymB2M7ovFU%3D Occurrence Handle8925585
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Nakata, M., Pavcnik, D., Uchida, B. et al. Comparison of Small Intestinal Submucosa-Covered and Noncovered Nitinol Stents with PTFE Endografts in Injured Ovine Femoral Arteries: A Pilot Study . CVIR 26, 459–467 (2003). https://doi.org/10.1007/s00270-003-3008-z
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00270-003-3008-z