Abstract
The endovascular repair of abdominal aortic aneurysm (AAA) with stent grafts is rapidly becoming an important alternative to open repair. Suprarenal stent grafting, recently modified from conventional infrarenal stent grafting, is a technique for the purpose of treating patients with inappropriate aneurysm necks. Unlike open repair, the success of endoluminal repair cannot be ascertained by means of direct examination and thus relies on imaging results. The use of conventional angiography for arterial imaging has become less dominant, while helical computed tomography angiography (CTA) has become the imaging modality of choice for both preoperative assessment and postoperative followup after treatment with stent graft implants. There is an increasing likelihood that radiologists will become more and more involved in the procedure of aortic stent grafting and in giving the radiological report on these patients treated with stent grafts. It is necessary for radiologists to be familiar with the imaging findings, including common and uncommon appearances following aortic stent grafting. The purpose of this pictorial essay is to describe and present normal and abnormal imaging appearances following aortic stent grafting based on helical CTA.
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00270-003-0034-9/MediaObjects/fig1.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00270-003-0034-9/MediaObjects/fig2.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00270-003-0034-9/MediaObjects/fig3.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00270-003-0034-9/MediaObjects/fig4.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00270-003-0034-9/MediaObjects/fig5.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00270-003-0034-9/MediaObjects/fig6.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00270-003-0034-9/MediaObjects/fig7.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00270-003-0034-9/MediaObjects/fig8.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00270-003-0034-9/MediaObjects/fig9.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00270-003-0034-9/MediaObjects/fig10.gif)
Similar content being viewed by others
References
GD Rubin S Napel AN Leung (1996) ArticleTitleVolumetric analysis of volumetric data: Achieving a paradigm shift. Radiology 200 312–317 Occurrence Handle1:STN:280:BymB1MvlsFw%3D Occurrence Handle8685316
J Rydberg KK Kopecky MS Johnson NH Patel SA Pershon SG Lalka (2001) ArticleTitleEndovascular repair of abdominal aortic aneurysms: Assessment with multislice CT. AJR 177 607–614 Occurrence Handle1:STN:280:DC%2BD3MvntFKrug%3D%3D
M Prokop (2000) ArticleTitleMultislice CT angiography. Eur J Radiol 36 86–96 Occurrence Handle10.1016/S0720-048X(00)00271-0 Occurrence Handle1:STN:280:DC%2BD3M7ht1GitA%3D%3D Occurrence Handle11116172
R Dorffner S Thurnher S Youssefzadeh F Winkelbauer T Holzenbein P Polterauer J Lammer (1997) ArticleTitleSpiral CT angiography in the assessment of abdominal aortic aneurysms after stent grafting: Value of maximum intensity projections. J Comput Assit Tomgr 21 472–477 Occurrence Handle10.1097/00004728-199705000-00025 Occurrence Handle1:STN:280:ByiB1c7jsFc%3D
J Rydberg KK Kopecky SG Lalka MS Johnson MC Dalsing SA Perohn (2001) ArticleTitleStent grafting of abdominal aortic aneurysms: Pre- and postoperative evaluation with multislice helical CT. J Comput Assit Tomgr 25 580–586 Occurrence Handle10.1097/00004728-200107000-00013 Occurrence Handle1:STN:280:DC%2BD3MvisVCgtg%3D%3D
SC Whitaker (2001) ArticleTitleImaging of abdominal aortic aneurysm before and after endoluminal stent graft repair. Eur J Radiol 39 3–15 Occurrence Handle10.1016/S0720-048X(01)00337-0 Occurrence Handle1:STN:280:DC%2BD3MzosFanug%3D%3D Occurrence Handle11439226
T Whitbread P Birch S Rogers JD Beard PA Gaines (1997) ArticleTitleThe effect of placing an aortic wallstent across the renal artery origins in an animal model. Eur J Vasc Endovasc Surg 13 154–158 Occurrence Handle1:STN:280:ByiB38njtV0%3D Occurrence Handle9091148
P Desgranges E Hutin C Kedzia E Allaire JP Becquemin (1997) ArticleTitleAortic stents covering the renal arteries ostia: An animal study. J Vasc Intervent Radiol 8 77–82 Occurrence Handle1:STN:280:ByiC2sjlt1w%3D
M Tillich RE Bell DS Paik D Fleischmann MC Sofilos LJ Logan GD Rubin (2001) ArticleTitleIliac arterial injuries after endovascular repair of abdominal aortic aneurysms: correlation with iliac curvature and diameter. Radiology 219 129–136 Occurrence Handle1:STN:280:DC%2BD3M7oslKhtw%3D%3D Occurrence Handle11274547
JJ Wever JD Blankensteijn WP Mali BC Eikelboom (2000) ArticleTitleMaximal aneurysm diameter follow-up is inadequate after endovascular abdominal aortic aneurysm repair. Eur J Vasc Endovasc Surg 20 177–182 Occurrence Handle10.1053/ejvs.1999.1051 Occurrence Handle1:STN:280:DC%2BD3cvjtlOhtQ%3D%3D Occurrence Handle10942691
M Malina J Brunkwall B Lindblad T Resch K Ivancey (1999) ArticleTitleEndovascular management of the juxtarenal aortic aneurysm: Can uncovered stents safely cross the renal arteries? Semin Vasc Surg 12 182–191 Occurrence Handle1:STN:280:DyaK1Mvis1Gnuw%3D%3D Occurrence Handle10498261
Sun Z, Winder J, Kelly B, Ellis P, Hirst D (2003) CT virtual intravascular endoscopy of abdominal aortic aneurysms treated with suprarenal endovascular stent grafting. Abdom Imaging (in press)
U Blum G Voshage J Lammer F Beyersdorf D Tollner G Kretschmer G Spillner P Polterauer G Nagel T Holzenbein (1997) ArticleTitleEndoluminal stent-grafts for infrarenal abdominal aortic aneurysms. N Eng J Med 336 13–20 Occurrence Handle10.1056/NEJM199701023360103 Occurrence Handle1:STN:280:ByiC383ksFM%3D
GH White W Yu J May X Chaufour MS Stephen (1997) ArticleTitleEndoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: Classification, incidence, diagnosis and management. J Endovasc Surg 4 152–168 Occurrence Handle1:STN:280:ByiA38fks1E%3D Occurrence Handle9185003
T Resch K Ivancev M Lindh V Nyman J Brunkwall M Malina B Lindblad (1998) ArticleTitlePersistent collateral perfusion of abdominal aortic aneurysm after endovascular repair does not lead to progressive change in aneurysm diameter. J Vasc Surg 28 242–249 Occurrence Handle1:STN:280:DyaK1czotlyjsw%3D%3D Occurrence Handle9719319
JA Kaufman SC Geller DC Brewster CM Fan RP Cambria GM LaMuraglia JP Gertler WM Abbott AC Waltman (2000) ArticleTitleEndovascular repair of abdominal aortic aneurysms: Current status and future directions. AJR 175 289–302 Occurrence Handle1:STN:280:DC%2BD3cvgvVSgsg%3D%3D
GH White J May RC Waugh X Chaufour W Yu (1998) ArticleTitleType III and type IV endoleak: Towards a complete definition of blood flow in the sac after endoluminal aortic aneurysm repair. J Endovasc Surg 5 305–309 Occurrence Handle1:STN:280:DyaK1M%2FotlajtQ%3D%3D Occurrence Handle9867318
ML Marin RE Parsons LH Hollier HA Mitty J Ahn T Temudom M D’Ayala M McLaughlin L DePalo R Kahn (1998) ArticleTitleImpact of transrenal aortic endograft placement on endovascular graft repair of abdominal aortic aneurysms. J Vasc Surg 28 638–646 Occurrence Handle1:STN:280:DyaK1M%2FgtVWqtQ%3D%3D Occurrence Handle9786258
JA Burks PL Faries EC Gravereaux LH Hollier ML Marin (2002) ArticleTitleEndovascular repair of abdominal aortic aneurysms: Stent-graft fixation across the visceral arteries. J Vasc Surg 35 109–113 Occurrence Handle10.1067/mva.2002.119387 Occurrence Handle11802140
MD Armerding GD Rubin CF Beaulieu SM Slonim EW Olcott SL Samuels MJ Jorgensen CP Semba RB Jr. Jeffrey MD Dake (2000) ArticleTitleAortic aneurysmal disease: Assessment of stent-grafted treatment-CT versus conventional angiography. Radiology 215 138–146 Occurrence Handle1:STN:280:DC%2BD3c3hslWrsQ%3D%3D Occurrence Handle10751479
J Golzarian L Dussaussois HT Abada PA Genenois D Van Gansbeke J Ferreira J Struyven (1998) ArticleTitleHelical CT of aorta after endoluminal stent-graft therapy: Value of biphasic acquisition. AJR 171 329–331 Occurrence Handle1:STN:280:DyaK1czlslyiug%3D%3D
DO Kessel I Robertson J 5th Patel K Peters EJ Taylor LJ Denton B Bambhra (2002) ArticleTitleCarbon-dioxide-guided vascular interventions: Technique and pitfalls. Cardiovasc Intervent Radiol 25 476–483 Occurrence Handle10.1007/s00270-002-1925-x Occurrence Handle12132028
MR Back JG Caridi IF Jr Hawkins JM Seeger (1998) ArticleTitleAngiography with carbon dioxide (CO2). Surg Clin North Am 78 575–591 Occurrence Handle1:STN:280:DyaK1czpslCnug%3D%3D Occurrence Handle9728202
E Neri D Caramella C Bisogni E Laiolo F Trincavelli A Viviani C Vignali R Cioni C Bartolozzi (1999) ArticleTitleDetection of accessory renal arteries with virtual vascular endoscopy of the aorta. Cardiovasc Intervent Radiol 22 1–6
SB Bauer AD Perlmutter AB Retik (1992) Anomalies of the upper urinary tract. PC Walsh (Eds) Campbell’s urology, sixth edn W.B. Saunders Philadelphia 1357–1435
DB Kaplan CC Kwon ML Marin LH Hollier (1999) ArticleTitleEndovascular repair of abdominal aortic aneurysms in patients with congenital renal vascular anomalies. J Vasc Surg 30 407–416 Occurrence Handle1:STN:280:DyaK1Mvgs1yksg%3D%3D Occurrence Handle10477633
RA Aquino RY Rhee SC Muluk EY Tzeng NM Carrol MS MaKaroun (2001) ArticleTitleExclusion of accessory renal arteries during endovascular repair of abdominal aortic aneurysms. J Vasc Surg 6 1–8
M Malina K Ivancev TA Chuter M Lindh T Lanne B Lindblad J Brunkwall B Risberg (1997) ArticleTitleChanging aneurysmal morphology after endovascular grating: relation to leakage or persistent perfusion. J Endovasc Surg 4 23–30 Occurrence Handle1:STN:280:ByiC1cjks1Y%3D Occurrence Handle9034915
M Malina J Brunkwall K Ivancev J Jonsson J Malina B Lindblad (2000) ArticleTitleEndovascular healing is inadequate for fixation of Dacron stent grafts in human aortailiac vessels. Eur J Vasc Endovasc Surg 19 5–11 Occurrence Handle10.1053/ejvs.1999.0867 Occurrence Handle1:STN:280:DC%2BD3c7ntlyhtw%3D%3D Occurrence Handle10706828
W Moore (1997) ArticleTitleThe EVT tube and bifurcated endograft systems: Technical considerations and clinical summery. J Endovasc Surg 4 182–194 Occurrence Handle1:STN:280:ByiA38fks1w%3D Occurrence Handle9185006
M Malina B Lindblad K Ivancev M Lindh J Malina J Brunkwall (1998) ArticleTitleEndovascular AAA exclusion: Will stents with hooks and barbs prevent stent-graft migration? J Endovasc Surg 5 310–317 Occurrence Handle1:STN:280:DyaK1M%2Fotlajug%3D%3D Occurrence Handle9867319
T Resch K Ivancev J Brunkwall V Nyman M Malina B Lindblad (1999) ArticleTitleDistal migration of stent-grafts after endovascular repair of abdominal aortic aneurysms. J Vasc Intervent Radiol 10 257–264 Occurrence Handle1:STN:280:DyaK1M3gtVeisw%3D%3D
R Sawhney RK Kerlan SD Wall LM Reilly TA Chuter DE Ruiz CJ Canto JM LaBerge LM Reilly J Yee MW Wilson J Jean-Claude RM Farugi RL Gordon (2001) ArticleTitleAnalysis of initial CT findings after endovascular repair of abdominal aortic aneurysm. Radiology 220 157–160 Occurrence Handle1:STN:280:DC%2BD3MzmsVOqug%3D%3D Occurrence Handle11425989
K Schurmann D Vorwerk A Bucker J Neurburg B Klosterhalfen A Bucker RW Gunther (1997) ArticleTitlePerigraft inflammation due to dacron-covered stent-grafts in sheep iliac arteris: Correlation of MR imaging and histopathological findings. Radiology 204 757–763 Occurrence Handle1:STN:280:ByiH38vjtlc%3D Occurrence Handle9280255
SR Vallabhaneni RG McWilliams A Anbarasu PC Rowlands JA Brennan DA Gould PL Harris (2001) ArticleTitlePerianeurysmal fibrosis: A relative contra-indication to endovascular repair. Eur J Vasc Endovasc Surg 22 535–541 Occurrence Handle10.1053/ejvs.2001.1521 Occurrence Handle1:STN:280:DC%2BD3MnptFKjtg%3D%3D Occurrence Handle11735203
WG Tennant GG Hartnell RN Baird M Horrocks (1993) ArticleTitleRadiologic investigation of abdominal aortic aneurysm disease: Comparison of three modalities in staging and the detection of inflammatory change. J Vasc Surg 17 703–709 Occurrence Handle10.1067/mva.1993.40728 Occurrence Handle1:STN:280:ByyB3MfgtF0%3D Occurrence Handle8464089
L Engellau EM Larsson U Albrechtsson T Jonung E Ribbe J Thorne Z Zdanowski L Norgren (1998) ArticleTitleMagnetic resonance imaging and MR angiography of endoluminally treated abdominal aortic aneurysms. Eur J Vasc Endovasc Surg 15 212–219 Occurrence Handle1:STN:280:DyaK1c3kvVyrtw%3D%3D Occurrence Handle9587333
OC Velazquez JP Carpenter RA Baum CF Barker M Golden F Criado A Pyeron RM Fairman (1999) ArticleTitlePerigraft air, fever, and leukocytosis after endovascular repair of abdominal aortic aneurysms. Am J Surg 178 185–189 Occurrence Handle10.1016/S0002-9610(99)00144-0 Occurrence Handle1:STN:280:DyaK1MvlsVGmuw%3D%3D Occurrence Handle10527435
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Sun, Z. Helical CT Angiography of Abdominal Aortic Aneurysms Treated with Suprarenal Stent Grafting: A Pictorial Essay . CVIR 26, 290–295 (2003). https://doi.org/10.1007/s00270-003-0034-9