Abstract
Capsular contracture is the most troublesome and distressing complication after breast augmentation for both the surgeon and patient. The etiology of capsular contracture remains unclear. Clinical treatment for this complication is based on the surgeon’s evaluation, the condition of the breast, and a number of other factors. In a previous study, the authors investigated whether measurement of mammary compliance as a means of assessing capsular contracture was comparable with other methods described for the assessment of capsular contracture. The purpose of this study was to evaluate whether capsular contracture varies significantly over time. A prospective study was performed to measure mammary compliance in 60 female patients who received a total of 120 implants between 2000 and 2002. The implants used were anatomic prostheses filled with cohesive silicone gel and round double-lumen prostheses filled with silicone gel and saline solution. All the patients were followed up for at least 2 years. Statistical analysis of the data also was performed to assess significance. The results showed a general trend in mammary compliance values over time.
Similar content being viewed by others
References
Alfano C, Costantini M, Mazzocchi M: Clinical examination and follow-up of mammary implants. Eur Plast Surg Rew 4:4–8, 1999
Alfano C, Mazzocchi M, Scuderi N: Mammary compliance: An objective measurement of capsular contracture. Aesth Plast Surg 28:75–79, 2004
Baker JL: Augmentation mammoplasty. In: Owsley JQ, Peterson R (eds) Symposium on aesthetic surgery of the breast. Mosby: St Louis, pp. 125–152, 1978
Baker JL: Classification of spherical contractures. Read at the Aesthetic Breast Symposium, Scottsdale, Arizona, 1975
Becker H, Springer R: Prevention of capsular contracture. Plast Reconstr Surg 103:1766–1768, 1999
Burkhardt BR, Schhnur PL Tofield JJ, Dempsey PD: An objective clinical assessment of fibrosus capsular contracture. Plast Reconstr Surg 69:794–799, 1982
Camirand A, Doucet J, Harris J: Breast augmentation: Compression: A very important factor in preventing capsular contracture. Plast Reconstr Surg 104:529–538, 1999
Chandler PJ, Jr. Talc and capsular contracture. Ann Plast Surg 52:288–292, 2004
Codner MA, Cohen AT, Hester TR: Complication in breast augmentation: Prevention and correction. Clin Plast Surg 28:587–596, 2001
Collis N, Sharpe D: Recurrence of subglandular breast implant capsular contracture: Anterior versus total capsulectomy. Plast Reconstr Surg 106:792–797, 2000
Eisenmann-Klein M: Breast implants: The past, the present, the future. Eur Plast Surg Rew 3:33–43, 1999
Fagrell D, Berggren A, Tarpila E: Capsular contracture around saline-filled fine textured and smooth mammary implants: A prospective 7.5-year follow-up. Plast Reconstr Surg 108:2108–2112, 2001
Gylbert LO: Applanation tonometry for the evaluation of breast compressibility. Scand J Plast Reconstr Surg Hand Surg 23:223–229, 1989
Gylbert LO: Constant compression caliper for objective measurement of breast capsular contracture. Scand J Plast Reconstr Surg Hand Surg 23:137–142, 1989
Hayes H, McLeod P: Indentation tonometry of the breasts. Plast Reconstr Surg 63:13–21, 1979
Hoflehner H, Pierer G: Subjective and objective assessment of capsular contracture. Eur J Plast Surg 17:69–74, 1994
Hoflehner H, Pierer G, Rehak P: Mammary compliance: An objective technique for measuring capsular fibrosis. Plast Reconstr Surg 80:1078–1084, 1993
Moore JR. Applanation tonometry of breasts. Plast Reconstr Surg 63:9–12, 1979
Mulder JW, Nicolai JP: Breast tonometry: A practical device for accurate measurement of capsule formation. Eur J Plast Surg 13:274–282, 1990
Rehak PH, Glanzer H: “ Mamma compliance transmitter”: A novel instrument for the objective measurement of the degree of capsular fibrosis following breast prosthesis implantation. Phys Med Biol 39a(Part 2):574–581, 1994
Rohrich R, Kenkel J, Adams W: Preventing capsular contracture in breast augmentation: In Search of the Holy Grail. Plast Reconstr Surg 103:1759–1760, 1999
Ulrich D, Lichtenegger F, Eblenkamp M, Repper D, Pallua N: Matrix metalloproteinases, tissue inhibitors of metalloproteinases, aminoterminal propeptide of procollagen type III, and hyaluronan in sera and tissue of patients with capsular contracture after augmentation with trilucent breast implants. Plast Reconstr Surg 114:229–236, 2004
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Mazzocchi, M., Alfano, C., Fioramonti, P. et al. Changes over Time in Mammary Compliance Values After Breast Augmentation. Aesth Plast Surg 30, 198–205 (2006). https://doi.org/10.1007/s00266-005-0165-2
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00266-005-0165-2