Abstract
Purpose
The aim of this study was to analyse possible indicative parameters for percutaneous ilio-sacral stabilisation and to identify parameters associated with screw misplacement.
Methods
Cohort study, level I trauma centre. Inclusion criteria: (1) unstable pelvic injury, (2) percutaneous ilio-sacral screws placement. Exclusion criteria: (1) sacral dysmorphy, (2) failed closed reduction, (3) navigated techniques. Indicative parameters were age, gender, body mass index, number of screws, screw angulation, fracture type and injury severity. End points were ilio-sacral screw position and associated complications. Screw placement accuracy was graded as follows: grade 0, no perforation; grade 1, perforation <2 mm; grade 2, perforation from 2 to 4 mm; grade 3, ≥4 mm perforation.
Results
Between March 2008 and March 2013, 102 (53 women) patients were included (mean age, 48.5 ± 21.4 years). The Injury Severity Score (ISS) and New Injury Severity Score (NISS) were 18.9 ± 9.9 and 22.3 ± 22.3, respectively. The positions of 137 ilio-sacral screws were analysed. Of all screws, 87.6 % (120) were placed satisfactory (<2 mm perforation). The incidence of screw misplacement was significantly higher in the case of two unilateral S1 screws compared with a single screw (failure rate: two unilateral screws 23.1 % vs single screw 7.0 %; p < 0.05). Screw perforation anterior to the lateral mass (in-out-in) represented the most frequent malposition. Revision was necessary in three cases due to malpositioning. Furthermore, no major complication occurred.
Conclusions
We conclude, that twofold ilio-sacral screw positioning from one side increases the risk for screw misplacement. In this case, alternative techniques like navigation should be considered. Anterior screw perforation represents a common problem with a high incidence and warrants particular attention.
Similar content being viewed by others
References
Collinge C, Coons D, Tornetta P, Aschenbrenner J (2005) Standard multiplanar fluoroscopy versus a fluoroscopically based navigation system for the percutaneous insertion of iliosacral screws: a cadaver model. J Orthop Trauma 19:254–258
Grossterlinden L, Rueger J, Catala-Lehnen P, Rupprecht M, Lehmann W, Rucker A, Briem D (2011) Factors influencing the accuracy of iliosacral screw placement in trauma patients. Int Orthop 35:1391–1396
Osterhoff G, Ossendorf C, Wanner GA, Simmen HP, Werner CM (2011) Percutaneous iliosacral screw fixation in S1 and S2 for posterior pelvic ring injuries: technique and perioperative complications. Arch Orthop Trauma Surg 131:809–813
Ziran BH, Smith WR, Towers J, Morgan SJ (2003) Iliosacral screw fixation of the posterior pelvic ring using local anaesthesia and computerised tomography. J Bone Joint Surg (Br) 85:411–418
Tschoeke SK, Hellmuth M, Hostmann A, Ertel W, Oberholzer A (2007) The early second hit in trauma management augments the proinflammatory immune response to multiple injuries. J Trauma 62:1396–1403, discussion 1403–1394
Hinsche AF, Giannoudis PV, Smith RM (2002) Fluoroscopy-based multiplanar image guidance for insertion of sacroiliac screws. Clin Orthop Relat Res 135–144
Smith HE, Yuan PS, Sasso R, Papadopolous S, Vaccaro AR (2006) An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws. Spine (Phila Pa 1976) 31:234–238
van den Bosch EW, van Zwienen CM, van Vugt AB (2002) Fluoroscopic positioning of sacroiliac screws in 88 patients. J Trauma 53:44–48
Wahnert D, Raschke MJ, Fuchs T (2013) Cement augmentation of the navigated iliosacral screw in the treatment of insufficiency fractures of the sacrum: a new method using modified implants. Int Orthop 37(6):1147–1150
Tile M (1996) Acute pelvic fractures: I. Causation and classification. J Am Acad Orthop Surg 4:143–151
Denis F, Davis S, Comfort T (1988) Sacral fractures: an important problem. Retrospective analysis of 236 cases. Clin Orthop Relat Res 227:67–81
Baker SP, O’Neill B, Haddon W Jr, Long WB (1974) The injury severity score: a method for describing patients with multiple injuries and evaluating emergency care. J Trauma 14:187–196
Harwood PJ, Giannoudis PV, Probst C, Van Griensven M, Krettek C, Pape HC (2006) Which AIS based scoring system is the best predictor of outcome in orthopaedic blunt trauma patients? J Trauma 60:334–340
Osler T, Baker SP, Long W (1997) A modification of the injury severity score that both improves accuracy and simplifies scoring. J Trauma 43:922–925, discussion 925–926
Routt ML Jr, Simonian PT, Mills WJ (1997) Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma 11:584–589
Rao G, Brodke DS, Rondina M, Dailey AT (2002) Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement. J Neurosurg 97:223–226
Vaccaro AR, Rizzolo SJ, Balderston RA, Allardyce TJ, Garfin SR, Dolinskas C, An HS (1995) Placement of pedicle screws in the thoracic spine. Part II: An anatomical and radiographic assessment. J Bone Joint Surg Am 77:1200–1206
Hauschild O, Strohm PC, Culemann U, Pohlemann T, Suedkamp NP, Koestler W, Schmal H (2008) Mortality in patients with pelvic fractures: results from the German pelvic injury register. J Trauma 64:449–455
Vigdorchik JM, Esquivel AO, Jin X, Yang KH, Vaidya R (2013) Anterior internal fixator versus a femoral distractor and external fixation for sacroiliac joint compression and single stance gait testing: a mechanical study in synthetic bone. Int Orthop 37(7):1341–1346
Vallier HA, Cureton BA, Patterson BM (2013) Factors affecting revenue from the management of pelvis and acetabulum fractures. J Orthop Trauma 27:267–274
Tonetti J, Cazal C, Eid A, Badulescu A, Martinez T, Vouaillat H, Merloz P (2004) Neurological damage in pelvic injuries: a continuous prospective series of 50 pelvic injuries treated with an iliosacral lag screw. Rev Chir Orthop Reparatrice Appar Mot 90:122–131
Zwingmann J, Konrad G, Mehlhorn AT, Sudkamp NP, Oberst M (2010) Percutaneous iliosacral screw insertion: malpositioning and revision rate of screws with regards to application technique (navigated vs. conventional). J Trauma 69:1501–1506
Gras F, Marintschev I, Wilharm A, Klos K, Muckley T, Hofmann GO (2010) 2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries—a case series. BMC Musculoskelet Disord 11:153
Moed BR, Geer BL (2006) S2 iliosacral screw fixation for disruptions of the posterior pelvic ring: a report of 49 cases. J Orthop Trauma 20:378–383
Compliance with ethical standards
This article does not contain any studies with human participants or animals performed by any of the authors.
For this type of study formal consent is not required.
Conflict of interest
The authors declare that they have no conflicts of interest.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Pishnamaz, M., Dienstknecht, T., Hoppe, B. et al. Assessment of pelvic injuries treated with ilio-sacral screws: injury severity and accuracy of screw positioning. International Orthopaedics (SICOT) 40, 1495–1501 (2016). https://doi.org/10.1007/s00264-015-2933-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00264-015-2933-1