Long axial field-of-view (LAFOV) PET/CT scanners have been introduced recently [1, 2], which offer numerous advantages [3]. One important advantage of using LAFOV PET/CT for imaging 89Zr-labelled monoclonal antibodies (mAbs), i.e., immunoPET, is the substantial increase in sensitivity compared with standard axial field-of-view (SAFOV) PET/CT systems, which may lead to a remarkable image quality improvement. This first study showcases such improvement for immunoPET with Biograph Vision Quadra™ (VQ) LAFOV PET/CT (Siemens Healthineers, Knoxville, TN, USA).

Two patients suffering from metastatic HER2-positive breast cancer were administered with 37 MBq [89Zr]trastuzumab in order to assist clinical decision-making [4, 5]. Patients were scanned 4 days postinjection with a Biograph™ mCT PET/CT (patient A) or a Biograph Vision™ PET/CT (patient B) (Siemens Healthineers, Knoxville, TN, USA), according to local standard operating procedures with overall scan durations of 45 min and 32 min, for, respectively, mCT and Vision. Following the clinical scans, patients were scanned with VQ. For VQ, we choose to apply a long scan duration of 30 min (patient A) and 32 min (patient B) to improve image quality rather than shortening the overall scan duration, as compared to Vision. For SAFOV systems, the acquisition and reconstruction parameters complied with EARL1, whilst for LAFOV, we also applied clinically (CLIN) recommended settings (Table 1) [6, 7].

Table 1 Acquisition and reconstruction parameters for the different systems

PET/CT images of patient A are shown in the top two rows (a-h), for patient B in the bottom rows (i-p). The same intensity scale, SUV range 0–10, applies for all images, except the fused images (e, m). Additional reconstructions of the Vision Quadra data were obtained, mimicking 3-min (d, h, l, p) and 10-min (c, g, k, o) acquisitions, illustrating more pragmatic scan durations.

As can be appreciated from these first human immunoPET images on a LAFOV system, the image quality improvement (f) is most spectacular when compared with the mCT (a). For example, in patient A, an additional small bone lesion was visualized with VQ in the pelvic area (f), which was not visible with the SAFOV system (a). Even when compared to the Vision (i), the VQ image (n) shows improved quality without applying any filter after reconstruction. Moreover, this image quality was improved even in the 10 min image compared with the 30–45 min acquisition needed for SAFOV systems.

Thus, this image shows that the large axial FOV system provides substantial improvement in image quality when applying currently preferred overall scan durations on SAFOV systems (45 min for mCT, 32 min for Vision). Additionally, with the new LAFOV system, there is room for further reduction of the overall scan duration with still very acceptable image quality, even for 89Zr-labelled mAb PET/CT studies.