Abstract
Attenuation correction may improve the diagnostic accuracy of myocardial perfusion imaging (MPI). However, few studies have dealt with the clinical consequences for reporting. We compared routine reports based on scatter-corrected MPI (MPI-routine) with consensus readings of scatter-corrected (MPI-scatter) and scatter plus attenuation-corrected studies (MPI-attenuation) to investigate the impact of attenuation correction on reporting. One hundred consecutive stable angina patients (including 55 men) were investigated in a 99mTc-sestamibi 2-day gated protocol with scatter and attenuation correction. With MPI-routine, 53 patients had normal perfusion and 47 abnormal perfusion, compared to 62 and 38 with MPI-attenuation, and 54 and 46, respectively, with MPI-scatter. Agreement between MPI-routine and MPI-attenuation with respect to overall diagnosis (normal/abnormal perfusion) was 89% (kappa=0.78) compared to 95% (kappa=0.90) between MPI-routine and MPI-scatter. With MPI-attenuation, the overall routine diagnosis changed in 11 patients, of which ten cases were judged normal after scatter plus attenuation correction. The majority of the “normalised” studies were among patients with apparently single-vessel RCA disease as judged from MPI. Agreement rates with regard to normal, reversible or irreversible defects between MPI-attenuation and MPI-routine for the LAD, LCX and RCA territories were 88%, 97% and 85%, respectively, without significant sex differences. In conclusion, attenuation correction caused a change in diagnosis in approximately 10% of the patients, corresponding to one-fifth of the abnormal studies. In all but one case, the shift was from abnormal to normal, mostly because of a different interpretation in the RCA territory.
Similar content being viewed by others
References
Beller GA, Zaret BL. Contributions of nuclear cardiology to diagnosis and prognosis of patients with coronary artery disease. Circulation 2000; 101:1465–1478.
Zaret BL, Beller GA. Nuclear cardiology. State of the art and future directions. In: Zaret BL, Beller GA, eds. St. Louis: Mosby, 1999.
Maddahi J. Myocardial perfusion imaging for detection and evaluation of coronary artery disease, In: Scorton DJ, Schelbert HR, Wolf GL, Brundage BH, eds. Cardiac imaging. A companion to Braunwald’s heart disease, 2nd edn. Philadelphia: Saunders; 1996:971–994.
Mahmarian JJ, Verani MS. Exercise thallium-201 perfusion scintigraphy in the assessment of coronary artery disease. Am J Cardiol 1991; 67:2D–11D.
Mahmarian JJ, Verani MS. Myocardial perfusion imaging during pharmacologic stress testing. Cardiol Clin 1994; 12:223–245.
Beller GA. Radionuclide perfusion imaging techniques for evaluation of patients with known or suspected coronary artery disease. Adv Intern Med 1997; 42:139–201.
Taillefer R, DePuey EG, Udelson JE, Beller GA, Latour Y, Reeves F. Comparative diagnostic accuracy of201Tl and 99mTc sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women. J Am Coll Cardiol 1997; 29:69–77.
Corbett JR, Ficaro EP. Clinical review of attenuation-corrected cardiac SPECT. J Nucl Cardiol 1999; 6:54–68.
Corbett JR, Ficaro EP. Attenuation corrected cardiac perfusion SPECT. Curr Opin Cardiol 2000; 15:330–336.
DePuey EG, Rozanski A. Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. J Nucl Med 1995; 36:952–955.
DePuey EG III. How to detect and avoid myocardial perfusion SPECT artifacts. J Nucl Med 1994; 35:699–702.
Smanio PE, Watson DD, Segalla DL, Vinson EL, Smith WH, Beller GA. Value of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging. J Am Coll Cardiol 1997; 30:1687–1692.
Golub RJ, Ahlberg AW, McClellan JR, et al. Interpretive reproducibility of stress99mTc sestamibi tomographic myocardial perfusion imaging. J Nucl Cardiol 1999; 6:257–269.
Johansen A, Gaster AL, Veje A, Thayssen P, Haghfelt T, Høilund-Carlsen PF. Interpretive intra- and interobserver reproducibility of rest/stress99Tcm-sestamibi myocardial perfusion SPECT in a consecutive group of male patients with stable angina pectoris before and after percutaneous transluminal angioplasty. Nucl Med Commun 2001; 22:531–537.
Ficaro EP, Fessler JA, Shreve PD, Kritzman JN, Rose PA, Corbett JR. Simultaneous transmission/emission myocardial perfusion tomography. Diagnostic accuracy of attenuation-corrected99mTc sestamibi single-photon emission computed tomography. Circulation 1996; 93:463–473.
Kluge R, Sattler B, Seese A, Knapp WH. Attenuation correction by simultaneous emission-transmission myocardial single-photon emission tomography using a technetium-99m-labelled radiotracer: impact on diagnostic accuracy. Eur J Nucl Med 1997; 24:1107–1114.
Gallowitsch HJ, Sykora J, Mikosch P, et al. Attenuation-corrected thallium-201 single-photon emission tomography using a gadolinium-153 moving line source: clinical value and the impact of attenuation correction on the extent and severity of perfusion abnormalities. Eur J Nucl Med 1998; 25:220–228.
Links JM, DePuey EG, Taillefer R, Becker LC. Attenuation correction and gating synergistically improve the diagnostic accuracy of myocardial perfusion SPECT. J Nucl Cardiol 2002; 9:183–187.
Links JM, Becker LC, Rigo P, et al. Combined corrections for attenuation, depth-dependent blur, and motion in cardiac SPECT: a multicenter trial. J Nucl Cardiol 2000; 7:414–425.
Kjaer A, Cortsen A, Rahbek B, Hasseldam H, Hesse B. Attenuation and scatter correction in myocardial SPET: improved diagnostic accuracy in patients with suspected coronary artery disease. Eur J Nucl Med Mol Imaging 2002; 29:1438–1442.
Lee DS, So Y, Cheon GJ, et al. Limited incremental diagnostic values of attenuation-noncorrected gating and ungated attenuation correction to rest/stress myocardial perfusion SPECT in patients with an intermediate likelihood of coronary artery disease. J Nucl Med 2000; 41:852–859.
Vidal R, Buvat I, Darcourt J, et al. Impact of attenuation correction by simultaneous emission/transmission tomography on visual assessment of201Tl myocardial perfusion images. J Nucl Med 1999; 40:1301–1309.
Hendel RC, Berman DS, Cullom SJ, et al. Multicenter clinical trial to evaluate the efficacy of correction for photon attenuation and scatter in SPECT myocardial perfusion imaging. Circulation 1999; 99:2742–2749.
Harel F, Genin R, Daou D, et al. Clinical impact of combination of scatter, attenuation correction, and depth-dependent resolution recovery for201Tl studies. J Nucl Med 2001; 42:1451–1456.
Almquist H, Arheden H, Arvidsson AH, Pahlm O, Palmer J. Clinical implication of down-scatter in attenuation-corrected myocardial SPECT. J Nucl Cardiol 1999; 6:406–411.
Banzo I, Pena FJ, Allende RH, Quirce R, Carril JM. Prospective clinical comparison of non-corrected and attenuation- and scatter-corrected myocardial perfusion SPECT in patients with suspicion of coronary artery disease. Nucl Med Commun 2003; 24:995–1002.
O’Connor MK, Kemp B, Anstett F, et al. A multicenter evaluation of commercial attenuation compensation techniques in cardiac SPECT using phantom models. J Nucl Cardiol 2002; 9:361–376.
Prvulovich EM, Lonn AH, Bomanji JB, Jarritt PH, Ell PJ. Transmission scanning for attenuation correction of myocardial201Tl images in obese patients. Nucl Med Commun 1997; 18:207–218.
Araujo LI, Jimenez-Hoyuela JM, McClellan JR, Lin E, Viggiano J, Alavi A. Improved uniformity in tomographic myocardial perfusion imaging with attenuation correction and enhanced acquisition and processing. J Nucl Med 2000; 41:1139–1144.
Ficaro EP, Fessler JA, Ackermann RJ, Rogers WL, Corbett JR, Schwaiger M. Simultaneous transmission-emission thallium-201 cardiac SPECT: effect of attenuation correction on myocardial tracer distribution. J Nucl Med 1995; 36:921–931.
Pretorius PH, Narayanan MV, Dahlberg ST, Leppo JA, King MA. The influence of attenuation and scatter compensation on the apparent distribution of99mTc sestamibi in cardiac slices. J Nucl Cardiol 2001; 8:356–364.
Kiat H, Van Train KF, Friedman JD, et al. Quantitative stress-redistribution thallium-201 SPECT using prone imaging: methodologic development and validation. J Nucl Med 1992; 33:1509–1515.
Hendel RC, Corbett JR, Cullom SJ, DePuey EG, Garcia EV, Bateman TM. The value and practice of attenuation correction for myocardial perfusion SPECT imaging: a joint position statement from the American Society of Nuclear Cardiology and the Society of Nuclear Medicine. J Nucl Cardiol 2002; 9:135–143.
Slart RHJA, Que TH, van Veldhuisen DJ, et al. Effect of attenuation correction on the interpretation of99mTc-sestamibi myocardial perfusion scintigraphy: the impact of 1 year’s experience. Eur J Nucl Med Mol Imaging 2003; 30:1505–1509. DOI 10.1007/s00259-003-1265-3.
Duvernoy CS, Ficaro EP, Karabajakian MZ, Rose PA, Corbett JR. Improved detection of left main coronary artery disease with attenuation-corrected SPECT. J Nucl Cardiol 2000; 7:639–648.
Liu YH, Lam PT, Sinusas AJ, Wackers FJ. Differential effect of 180 degrees and 360 degrees acquisition orbits on the accuracy of SPECT imaging: quantitative evaluation in phantoms. J Nucl Med 2002; 43:1115–1124.
Acknowledgements
The authors thank technologist Dorrit Østergaard for her assistance in processing the images.
Author information
Authors and Affiliations
Corresponding author
Additional information
This work was presented in part (as a poster) at the 6th International Conference of Nuclear Cardiology, Florence, Italy, April 29, 2003
Rights and permissions
About this article
Cite this article
Johansen, A., Grupe, P., Veje, A. et al. Scatter and attenuation correction changes interpretation of gated myocardial perfusion imaging. Eur J Nucl Med Mol Imaging 31, 1152–1159 (2004). https://doi.org/10.1007/s00259-004-1481-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00259-004-1481-5