Abstract
Background
We previously optimized several reconstruction strategies in SPECT myocardial perfusion imaging (MPI) with low dose for perfusion-defect detection. Here we investigate whether reducing the administered activity can also maintain the diagnostic accuracy in evaluating cardiac function.
Methods
We quantified the myocardial motion in cardiac-gated stress 99m-Tc-sestamibi SPECT studies from 163 subjects acquired with full dose (29.8 ± 3.6 mCi), and evaluated the agreement of the obtained motion/thickening and ejection fraction (EF) measures at various reduced dose levels (uniform reduction or personalized dose) with that at full dose. We also quantified the detectability of abnormal motion via a receiver-operating characteristics (ROC) study. For reconstruction we considered both filtered backprojection (FBP) without correction for degradations, and iterative ordered-subsets expectation-maximization (OS-EM) with resolution, attenuation and scatter corrections.
Results
With dose level lowered to 25% of full dose, the obtained results on motion/thickening, EF and abnormal motion detection were statistically comparable to full dose in both reconstruction strategies, with Pearson’s r > 0.9 for global motion measures between low dose and full dose.
Conclusions
The administered activity could be reduced to 25% of full dose without degrading the function assessment performance. Low dose reconstruction optimized for perfusion-defect detection can be reasonable for function assessment in gated SPECT.
Similar content being viewed by others
Abbreviations
- SPECT:
-
Single-photon emission computed tomography
- MPI:
-
Myocardial perfusion imaging
- FBP:
-
Filtered backprojection
- OS-EM:
-
Ordered-subsets expectation-maximization
- AC:
-
Attenuation correction
- SC:
-
Scatter correction
- RC:
-
Resolution correction
- AUC:
-
Area under the ROC curve
- CAD:
-
Coronary-artery disease
References
Choi JY, Lee KH, Kim SJ, Kim SE, Kim B-T, Lee SH, et al. Gating provides improved accuracy for differentiating artifacts from true lesions in equivocal fixed defects on technetium 99m tetrofosmin perfusion SPECT. J Nucl Cardiol. 1998;5:395–401.
Stratmann HG, Williams GA, Wittry MD, Chaitman BR, Miller DD. Exercise technetium-99m sestamibi tomography for cardiac risk stratification of patients with stable chest pain. Circulation. 1994;89:615–22.
Hachamovitch R, Berman DS, Kiat H, Cohen I, Cabico JA, Friedman J, et al. Exercise myocardial perfusion SPECT in patients without known coronary artery disease: Incremental prognostic value and use in risk stratification. Circulation. 1996;93:905–14.
Piccini JP, Horton JR, Shaw LK, Al-Khatib SM, Lee KL, Iskandrian AE, et al. SPECT myocardial perfusion defects are associated with an increased risk of all-cause death, cardiovascular death and sudden cardiac death. Circulation. 2008;1:180–8.
Gimelli A, Rossi G, Landi P, Marzullo P, Iervasi G, L’Abbate A, et al. Stress/rest myocardial perfusion abnormalities by gated SPECT: Still the best predictor of cardiac events in stable ischemic heart disease. J Nucl Med. 2009;50:546.
Administration UFaD (2010) Initiative to reduce unnecessary radiation exposure from medical imaging. US Food and Drug Administration, p. 9.
Jerome SD, Tilkemeier PL, Farrell MB, Shaw LJ. Nationwide laboratory adherence to myocardial perfusion imaging radiation dose reduction practices: A report from the intersocietal accreditation commission data repository. JACC. 2015;8:1170–6.
Cerqueira MD, Allman KC, Ficaro EP, Hansen CL, Nichols KJ, Thompson RC, et al. Recommendations for reducing radiation exposure in myocardial perfusion imaging. J Nucl Cardiol. 2010;17:709–18.
Juan Ramon A, Yang Y, Pretorius PH, Slomka PJ, Johnson KL, King MA, et al. Investigation of dose reduction in cardiac perfusion SPECT via optimization and choice of the image reconstruction strategy. J Nucl Cardiol. 2017. https://doi.org/10.1007/s12350-017-0920-1.
Juan Ramon A, Yongyi Y, Pretorius PH, King MA, Wernick MN (2018) Personalized models for injected activity levels in SPECT myocardial perfusion imaging Trans Med Imaging
Germano G, Kavanagh PB, Slomka PJ, Van Kriekinge SD, Pollard G, Berman DS. Quantitation in gated perfusion SPECT imaging: the Cedars-Sinai approach. J Nucl Cardiol. 2007;14:433–54.
Bai C, Shao L, Da Silva AJ, Zhao Z. A generalized model for the conversion from CT numbers to linear attenuation coefficients. IEEE Trans Nucl Sci. 2003;50:1510–5.
Klein G, Reutter B, Huesman R, Budinger T (1998) Cardiac gating of transmission data is unnecessary for attenuation compensation of double-gated emission scans. Nuclear Science Symposium, 1998 Conference Record 1998, IEEE. pp. 2019–2022
Hoffman EA, Ritman EL. Invariant total heart volume in the intact thorax. Am J Physiol-Heart Circ Physiol. 1985;249:H883–90.
Jin M, Niu X, Qi W, Yang Y, Dey J, King MA, et al. 4D reconstruction for low-dose cardiac gated SPECT. Med Phys. 2013;40(2):022501.
Narayanan MV, King MA, Pretorius PH, Dahlberg ST, Spencer F, Simon E, et al. Human-observer receiver-operating-characteristic evaluation of attenuation, scatter, and resolution compensation strategies for 99mTc myocardial perfusion imaging. J Nucl Med. 2003;44:1725–34.
Ogawa K, Harata Y, Ichihara T, Kubo A, Hashimoto S. A practical method for position-dependent Compton-scatter correction in single photon emission CT. IEEE Trans Med Imaging. 1991;10:408–12.
King M, Pan T-S, Pretorius P, Case J. An investigation of the filtering of TEW scatter estimates used to compensate for scatter with ordered subset reconstructions. IEEE Trans Nucl Sci. 1997;44:1140–5.
Slomka PJ, Berman DS, Xu Y, Kavanagh P, Hayes SW, Dorbala S, et al. Fully automated wall motion and thickening scoring system for myocardial perfusion SPECT: Method development and validation in large population. J Nucl Cardiol. 2012;19:291–302.
Morrison DF. Multivariate analysis of variance. Hoboken: Wiley; 2005.
Keppel G, Wickens T. Simultaneous comparisons and the control of type I errors. Design and analysis: A researcher’s handbook. 4th ed. Pearson Prentice Hall: Wiley; 2004. p. 111–30.
Team R (2015) RStudio: integrated development for R. RStudio, Inc, Boston, MA. http://www.rstudio.com
Metz C, Lorenzo LP, Papaioannu J (2011) ROC-kit software. http://metz-roc.uchicago.edu/MetzROC/software
Lecchi M, Martinelli I, Zoccarato O, Maioli C, Lucignani G, Del Sole A. Comparative analysis of full-time, half-time, and quarter-time myocardial ECG-gated SPECT quantification in normal-weight and overweight patients. J Nucl Cardiol. 2017;24(3):876–87.
Kortelainen MJ, Koivumäki TM, Vauhkonen MJ, Hakulinen MA. Dependence of left ventricular functional parameters on image acquisition time in cardiac-gated myocardial perfusion SPECT. J Nucl Cardiol. 2015;22:643–51.
Acknowledgements
This work was supported by the National Institutes of Health (NIH) Grant R01-HL122484. P.S. was also supported by NIH Grant R01-HL089765. The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH.
Disclosure
The University of Massachusetts had a research agreement with Philips Healthcare at the time some of this work was performed.
Author information
Authors and Affiliations
Corresponding author
Additional information
The authors of this article have provided a PowerPoint file, available for download at SpringerLink, which summarises the contents of the paper and is free for re-use at meetings and presentations. Search for the article DOI on SpringerLink.com.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
Juan Ramon, A., Yang, Y., Wernick, M.N. et al. Evaluation of the effect of reducing administered activity on assessment of function in cardiac gated SPECT. J. Nucl. Cardiol. 27, 562–572 (2020). https://doi.org/10.1007/s12350-018-01505-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12350-018-01505-x