Skip to main content

Advertisement

Log in

Variability in the range of inter-anterior superior iliac spine distance and its correlation with femoral head centre. A prospective computed tomography study of 200 adults

  • Scientific Article
  • Published:
Skeletal Radiology Aims and scope Submit manuscript

Abstract

Purpose

The anterior superior iliac spine (ASIS) is commonly used to estimate the centre of the femoral head and assess limb alignment during surgical procedures. This study aimed to determine the range of inter-anterior superior iliac spine distances (IADs) and inter-femoral head centre distances (IFDs) among individuals and ascertain whether there is correlation between the IFD and the IAD. We also sought to determine whether gender, height and body mass index (BMI) had any influence on IAD and IFD.

Materials and methods

We prospectively measured IAD and IFD in 200 adults, using transverse computed tomography (CT) scans done for medical causes. We also calculated the distance between the pelvic midline and the centre of the femoral head (XY distance) from the measured IFD. The influence of gender, height and body-mass index on IAD and IFD, and the correlation of IAD with IFD, were also studied.

Results

The overall mean IAD, IFD and XY distances were 22.7 ± 1.6 cm, 16.0 ± 0.8 cm and 8.0 ± 0.4 cm, respectively. There was wide variation within the IAD range with 50% (100/200) of the subjects having their IAD within ±10 mm of the mean compared to 75.5% (151/200) of the subjects with IFD within ±10 mm of the mean. The probability that the mean XY distance would fall within 10 mm of the true femoral head centre in all subjects was 100%. The gender difference in IAD and IFD was statistically significant (P = 0.03 and P < 0.001, respectively), height and BMI had no influence, and the correlation of IAD with IFD was weak (0.35).

Conclusion

Although the range of IADs showed wide variation among subjects, this study clearly demonstrated the narrow range of the XY distance and IFD in the study population and provides a useful and accurate basis for a new method to determine the femoral head centre clinically and intraoperatively.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. Hooper G, Leslie H, Burn J, Schouten R, Beci I. Oblique upper tibial opening wedge osteotomy for genu varum. Oper Orthop Traumatol. 2005;17:662–73.

    Article  PubMed  Google Scholar 

  2. Seidel GK, Marchinda DM, Dijkers M, Soutas-Little RW. Hip joint centre location from palpable bony landmarks: a cadaver study. J Biomech. 1995;28:995–8.

    Article  CAS  PubMed  Google Scholar 

  3. Purkait R, Chandra H. A study of sexual variation in Indian femur. Forensic Sci Int. 2004;146:25–33.

    Article  PubMed  Google Scholar 

  4. Sawant MR, Murty A, Ireland J. A clinical method for locating the femoral head centre during total knee arthroplasty. Knee. 2004;11:209–12.

    Article  CAS  PubMed  Google Scholar 

  5. Ritter MA, Campbell ED. A model for easy location of the centre of the femoral head during total knee arthroplasty. J Arthroplasty. 1988;3(Suppl):S59–61.

    Article  PubMed  Google Scholar 

  6. Horton GA, Reckling FW. Femoral pulse as a guide to the mechanical axis in total knee arthroplasty. J Arthroplasty. 1995;10:780–4.

    Article  CAS  PubMed  Google Scholar 

  7. Matsuda Y, Ishii Y, Ichimura K. Identifying the centre of the femoral head using ultrasonography to assess the higher accuracy of femoral extramedullary guides in TKA. J Orthop Sci. 2004;9:6–9.

    Article  PubMed  Google Scholar 

  8. Bargren JH, Blaha JD, Freeman MA. Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop. 1983;173:178–83.

    PubMed  Google Scholar 

  9. Denham RA, Bishop RE. Mechanics of the knee and problems in reconstructive surgery. J Bone Joint Surg Br. 1978;60:345–52.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Arun Mullaji.

Additional information

No benefits or funds were received in support of this study. The study was approved by the Ethics Committee of the Breach Candy Hospital.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Mullaji, A., Shetty, G.M., Kanna, R. et al. Variability in the range of inter-anterior superior iliac spine distance and its correlation with femoral head centre. A prospective computed tomography study of 200 adults. Skeletal Radiol 39, 363–368 (2010). https://doi.org/10.1007/s00256-009-0791-x

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00256-009-0791-x

Keywords

Navigation