Skip to main content
Log in

Contrast-enhanced MR angiography in patients with carotid artery stenosis: comparison of two different techniques with an unenhanced 2D time-of-flight sequence

  • DIAGNOSTIC NEURORADIOLOGY
  • Published:
Neuroradiology Aims and scope Submit manuscript

Abstract

Conventional time-of-flight (TOF) MR angiography (MRA) in carotid artery stenosis relies on flow-related enhancement to produce signal from vascular structures. Intravoxel phase dispersion, due to vortices, causes loss of signal and is the reason for the tendency to overestimate the degree of stenosis. In contrast-enhanced MRA, intravascular signal is mainly dependent on T1 shortening of the blood. We compared first-pass contrast-enhanced MRA (contrast-enhanced 3D gradient echo, ce3D GRE) and contrast-enhanced 2D TOF (ce2D TOF) sequences with an unenhanced 2D TOF in 13 patients with carotid artery stenosis, assessing delineation of the carotid bifurcation, enhancement of veins and grade of stenosis. The contrast-enhanced techniques produced more morphological detail, the ce3D GRE being superior to the ce2D TOF. Four carotid arteries were reclassified into lesser stenosis categories using the ce3D GRE technique. However, seven carotid arteries (27 %) were rated as nondiagnostic on the ce3D GRE, mainly due to masking of the carotid bifurcation by veins. The latter can be avoided by decreasing the acquisition time; on our 1.5-T system we could achieve a minimum time of 23 s per 3D GRE. Further reduction of acquisition time would be necessary to incorporate this method into clinical routine, requiring higher-performance gradients, which are not available in many UK hospitals.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 25 February 1999 Accepted: 29 July 1999

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jäger, H., Moore, E., Bynevelt, M. et al. Contrast-enhanced MR angiography in patients with carotid artery stenosis: comparison of two different techniques with an unenhanced 2D time-of-flight sequence. Neuroradiology 42, 240–248 (2000). https://doi.org/10.1007/s002340050879

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002340050879

Keywords

Navigation