Abstract
The real-time quantitative PCR (qPCR) calibration curves are highly reproducible and allow the generation of specific, sensitive, and reproducible data that can be used for gene quantification. However, it is important to rigorously validate the external calibration curve model in qPCR since absolute quantification is dependent on the standards used. We present a method for standardising qPCR-based quantification of the β-parvalbumin (β-pvalb) gene of Lophius piscatorius, a major fish allergen, using a plasmid DNA (pDNA) calibrator. In parallel experiments, standard curves were generated and compared from the genomic DNA (gDNA) isolated from L. piscatorius and pDNA carrying the target, pvalb. The commutability of pDNA and gDNA calibrators for the quantification of β-pvalb was assessed by employing a TaqMan qPCR, targeting the second intron of the pvalb gene of L. piscatorius. Higher PCR efficiencies, good linearity, and lower standard deviation (S.D.) values were observed with pDNA instead of gDNA calibrants. pDNA calibrants exhibited a lower bias in terms of closeness to the expected value of unknown samples than their genomic counterparts. The assay was specific and sensitive, where the limit of detection (LOD) and limit of quantification (LOQ) were five copies and ten copies per reaction. The short-term stability study of the pDNA calibrants indicated its stability for 60 days at − 20 °C and 30 days at 4 °C. The efficient results indicated a plasmid calibrator as a potential tool for absolute quantification of the pvalb gene and an alternative to conventional gDNA standards.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Quantitative PCR is currently the gold standard for nucleic acid quantification. There are various PCR-based quantification methods like qPCR, competitive PCR, and digital PCR. qPCR is the most precise and widely used method for gene quantification [1]. It is used for identification, quantification, and recombinant DNA (plasmid DNA) analysis, covering many medicine and food safety applications. In qPCR, the basic principle is the computation of DNA amplification through the level of fluorescence emitted during the synthesis of amplified double-stranded DNA (dsDNA). Although simple, there are some specific issues in qPCR, like standard selection, to achieve reliable quantification [2]. In this study, we constructed a plasmid DNA (pDNA)-based calibrator for absolute quantification of the β-pvalb gene in anglerfish (Lophius piscatorius), an important commercial fish.
Parvalbumins (Pvalbs) are heat-stable proteins from the calmodulin family, primarily found in the muscular tissues of vertebrates. A small acidic protein with high Ca2+ binding affinity comprising 108–109 amino acid residues with a molecular mass of 12 kDa is a major fish allergy-eliciting protein in humans [3, 4]. Prevention of adulteration is the commonly accepted reason for the development of detection tools that bypass the lack of morphological traits after processing fish meat. Less perceived, but not less important, is the factor associated with the wholesomeness of food, as in some consumers, consuming fish meat can trigger an allergic reaction. The scale of this reaction can start from mild symptoms, but it can reach, in extreme cases, life-threatening, severe conditions. Despite the general reactivity of such predisposed consumers to fish per se [5,6,7,8], in some individuals, their reactivity is limited to certain fish species [7, 9,10,11]. Especially for this reason, proper qualitative and quantitative determination of processed fish meat plays a role in public health.
Absolute quantification qPCR using a standard curve method is the most widely used technique in environmental and food microbiology [12,13,14]. The standard curve can be constructed by amplifying serial dilutions of known concentrations of standard templates, followed by linear regression of the logarithm of the DNA concentrations of the standard templates versus the threshold cycle (Ct). This method assumes that the sample's efficiency and standard are the same [2, 14, 15]. In practice, efficiency may not be similar, affecting accuracy. To overcome the efficiency fluctuations, both the standard dilutions and the unknown samples are amplified via the same protocol using the same amplification properties [16]. Therefore, the reliability and validity of the standard curve are of importance [17]. It also depends on the design and manufacture of the standard control, measurement of the exact concentration and long shelf life [18, 19].
The standard control or calibrator can be constructed using purified PCR amplicons, plasmid, genomic, cDNA or synthetic oligonucleotides. Recombinant pDNA and genomic DNA (gDNA) cloned together produce reproducible standard curves due to their high stability [19,20,21]. As various studies support the use of plasmid standard curves for absolute qPCR quantification, we also compare pDNA and gDNA standards. The advantages of plasmid calibrants are that they are relatively easy to construct, stable for extended periods when frozen, and can be manufactured, scaled up, and purified in large quantities over a broader working range [21].
An issue with DNA-based calibration curves is that they only undergo the PCR step, unlike the unknown mRNA samples in transcriptions studies, which must first be reverse transcribed. This increases the potential for variability in qPCR results, and the amplification results may not accurately compare to the results from the unknown samples [17, 18]. Substitution of the gDNA extracts by plasmid one fully addresses such technical challenges [22,23,24]. A stretch of DNA, like an amplicon originating from endpoint PCR, can be cloned into bacterial vectors. By action of enzymes ligases, an initial linear molecule of plasmid vector is circularised by adoption and a covalent bond connection with this DNA stretch [25]. The resulting clones are mainly selected by antibiotic resistance and screened for only those carrying inserted fragments utilising, e.g. the blue-white selection approach [26].
To find an alternative to the standard curve made from gDNA in quantitative PCR, an experiment using both genomic and cloned plasmid DNA needs to be performed [27]. The aim of this study was to confirm that the recombinant calibrator can be used in future plasmid assessments of the concentration or fraction of certain fish species in complex samples, reducing dependence on gDNA from specific fish species and standardising quantification abilities worldwide.
This article describes the successful cloning of L. piscatorius region of the second intron of the protein-coding part of the pvalb gene into a bacterial plasmid vector, pGEM-T Easy pvalb, and it is employed as a standard for quantification of pvalb. The resulting constructed pDNA was compared with the gDNA of L. piscatorius as standards for absolute qPCR assay. We also investigated the short-term stability of the plasmid standards against the gDNA standards, providing a tool in qPCR where the plasmid calibrator can substitute gDNA, which is the traditionally used assay.
Materials and methods
Sample collections and preparation
Fish samples of L. piscatorius (Lophiiformes, Lophiidae) were obtained from local fisheries and food stores in Prague, Czech Republic. Taxonomical identification was made from the label and was confirmed by ichthyologists from the Faculty of Science, Charles University. Fish tissue was stored in 50 ml tubes at − 20 °C for further downstream applications.
Isolation and quantification of DNA
The fish tissue was thawed and homogenised using a mortar before the extraction. gDNA extraction was performed using the NucleoSpin® Tissue kit (MACHEREY–NAGEL GmbH & Co. KG, Düren, Germany). The extractions were carried out according to the user manual procedures provided by the kit supplier. The reference samples from the panel of fishes were also extracted with the same kit. gDNA was eluted in 100 µl of elution buffer E. pDNA was isolated by PureYield™ Plasmid Miniprep System kit according to the manufacturer's instructions (Promega, Wisconsin, USA). After the chemical lysis of protein structures of bacteria, pDNA was eluted using the principle of silica membrane minicolumn. Samples were quantified spectrophotometrically using a NanoDrop (München, Germany). The A260/280 absorption ratio assessed the purity of the isolated DNA, wherein a value of 1.8 was considered pure.
Oligonucleotide primers
The primer pair targeting the second intron of β-pvalb of L. piscatorius was used as defined by Mukherjee et al. [28]. The primer pair was used to amplify the target region. Positive amplicons were purified and sequenced (SeqMe, Dobříš, Czech Republic). Obtained sequences were visualised and processed in BioEdit Sequence Alignment Editor, version 7.0.9.0 (California, USA) and used to design the probe (software Primer3Plus, Boston, USA) (Fig. 1) [29]. Primers (DAS F and DAS R) and probe (DAS_Probe1) used in the Taqman qPCR assay were as reported in Table 1. Primers and probe (Table 1) were synthesised by Generi Biotech (Hradec Kralove, Czech Republic).
Construction of target plasmid vector
Primers (DAS F and DAS R) were designed to clone into bacterial plasmid vector pGEM-T Easy Vector System, 3.2 kb (Promega, Wisconsin, USA) carrying the targeted region of the second intron of pvalb gene (196 bp) specific to L. piscatorius.
The thermal cycling conditions for PCR amplification were 95 °C, 5 min followed by 40 cycles of 94 °C, 30 s; 60 °C, 40 s; 72 °C, 60 s and a final extension of 72 °C, 7 min in Veriti™ Thermal cycler (Applied Biosystems, California, USA). The PCR products were analysed by agarose gel electrophoresis and purified using a PCR product purification kit (Qiagen GmbH, Hilden, Germany). The PCR amplicon concentration was assessed by NanoDrop (München, Germany). The PCR amplicons were directionally cloned into bacterial plasmid vector pGEM-T Easy Vector System and resulting product was designated as pGEM-T Easy pvalb (3.2 kb) (Promega, Wisconsin, USA). T4 DNA Ligase was used to create covalent bonds. Insert: vector molar ratio was kept 1:1. The plasmid was incorporated into E. coli JM109 High-Efficiency Competent Cells by heat shock according to the manufacturer's instructions (Promega, Wisconsin, USA). Selection of transformants was done on L.B. agar plates (SERVA Electrophoresis GmbH, Heidelberg, Germany) containing antibiotics, ampicillin with a final concentration of 100 µg/ml, with the addition of 0.5 mM IPTG (Carl Roth GmbH + Co., Karlsruhe, Germany) and 80 µg/ml X-gal (Carl Roth GmbH + Co., Karlsruhe, Germany), cultivated at 37 °C. White colonies carrying insert were picked up by sterile toothpick and inoculated in 2 ml L.B. medium containing antibiotic ampicillin (SERVA Electrophoresis GmbH, Heidelberg, Germany) and was incubated at 37 °C to OD A600 of 2.0–4.0. [27, 31] (Fig. 2). Verification of inserted product was confirmed by Sanger’s dideoxy sequencing (Generi Biotech, Hradec Kralove, Czech Republic).
Preparation of genomic DNA and plasmid standards
Genomic DNA extracted from L. piscatorius tissue was used to prepare a five-step serial dilution as standard with a copy number of 105–101. No carrier DNA was used for the preparation of gDNA standards.
Linearised plasmid with cloned intron segment, pGEM-T Easy pvalb (196 bp, Fig. 2) was used to prepare a five-step serial dilution as standard with copy numbers ranging from 105 to 101.
The copy number was calculated based on the genome size of L. piscatorius gDNA of 747.36 Mb and pDNA of 3.2 kb, with the formula described below (1) as proposed by Lee et al.[13]
The standards were used to construct standard curves and compare gDNA and pDNA PCR efficiency, linearity and regression coefficient. The results were used to derive and validate a plasmid-based calibrator for absolute quantification of L. piscatorius by qPCR.
qPCR
A StepOne plus™ qPCR system (Applied Biosystems, California, USA) was used to quantify the DNA by TaqMan assay (Applied Biosystems, California, USA) using primers and probes reported in Table 1. StepOne software V2.3 (Applied Biosystems, California, USA) was used to design the experiment and analyse the experimental data.
The reaction mix contained 10 μl of 2 × TaqMan™ Universal Master Mix 2 with UNG (Uracil-N-glycosylase) (Life Technologies, California, USA), which contained ROX Reference Dye (glycine conjugate of 5-carboxy-X rhodamine, succinimidyl ester) as a passive reference dye, primers (Table 1) at a final concentration of 0.4 mmol/l. 0.1 mmol/l probes (Table 2), 2 µl of template DNA (gDNA and pDNA) and nuclease-free water, the total reaction volume being 20 μl. The following thermal cycle profile was used: initial holding step at 50 °C for 2 min, initial denaturation and polymerase activation at 95 °C for 10 min, 35 cycles with denaturation at 95 °C for 15 s and annealing with polymerisation at 60 °C for 1 min. All PCR reactions were carried out in triplicates in three parallels.
Determination of limit of detection (LOD) and limit of quantification (LOQ)
LOD and LOQ are the most important parameters of a qPCR assay, referring to the lowest quantity of the target that can be reliably detected and quantified with a probability of ≥ 95% [32, 33]. Both LOD and LOQ are essential parameters in analytical chemistry and are used to determine the sensitivity and precision of analytical methods and instruments. The absolute limit is the lowest number of initial template copies that can be detected and quantified. The absolute LOD and LOQ of the TaqMan qPCR assay were determined by serially diluted pDNA and gDNA. All PCR runs were evaluated as cycle parameters described above.
Short-term stability study
The experimental design for the stability study of L. piscatorius gDNA and pGEM-T Easy pvalb pDNA was based on previously reported stability studies for plasmid calibrators [26]. Three tubes of each serial dilution of linearised pGEM-T Easy pvalb pDNA and gDNA standards were stored at 4 °C and − 20 °C. Aliquots of the gDNA and pDNA standards in triplicate were withdrawn after 0, 15, 30 and 60 days and evaluated as described above. PCR efficiency, regression coefficient and three parallel tests were performed in triplicates.
Statistical analysis
The PCR efficiency for the target-specific qPCR method and the linearity of corresponding regression lines calculated based on serial dilutions of the pDNA and gDNA calibrant were compared and statistically analysed using single-factor ANOVA. Statistical tests were performed using Microsoft Excel software (Analysis ToolPack for Microsoft Excel 2020).
Results and discussion
In the present work, we demonstrate the successful use of a plasmid-based (pGEM-T Easy pvalb) calibrator for absolute quantification of the β-pvalb gene targeting the second intron of pvalb of L. piscatorius. We used it as a model organism. DNA from L. piscatorius tissue was extracted using the NucleoSpin® Tissue kit. Nanodrop quantification was reported to be 412 ± 6 µg/µl. The primer set (DAS F and DAS R) is designed for gDNA amplification amplified Lophius samples.
Construction of pGEM-T Easy pvalb plasmid
The process of constructing the plasmid pGEM-T Easy pvalb involved inserting a 196 bp fragment of the second intron of the β-pvalb gene from L. piscatorius into the pGEM-T Easy vector (Fig. 2). This resulted in the formation of the plasmid pGEM-T Easy pvalb, as shown in Fig. 2B. The DNA sequence of pGEM-T Easy pvalb was then confirmed to contain the 196 bp pvalb sequence.
qPCR
A TaqMan qPCR assay targeting the second intron of the pvalb gene in the plasmid DNA forms the foundation of the present study. The TaqMan assay was used to detect both gDNA and pDNA independently. The standard curve was generated with a fivefold dilution ranging from 105 to 101 copies of gDNA and pDNA per reaction. The CT value was plotted against the log of copy number for both calibrants (Fig. 3). Simple linear regression (least squares analysis) was applied to each data set comprising the calibration curve to give the best fitting straight line accommodating all the data points. A multi-parametric approach was adopted wherein the correlation coefficient (R2) and PCR efficiencies of the pDNA and gDNA system calibration curves were compared.
Comparison of PCR efficiency of the calibrants
PCR efficiency, a measure of how closely the majority of the PCR cycles in a given run approximate a perfect duplication of product, is one of the most important parameters in determining the reliability and performance of an assay [2]. An efficient qPCR has an efficiency close to 100%; however, if the efficiency is low, it can lead to inaccurate quantification, as the relationship between the starting template and amplified product becomes non-linear. The mean amplification efficiency of pDNA and gDNA was reported to be 100.64% and 104.18%, respectively. Three parallel tests were performed in triplicates, and a single-factor ANOVA indicated no significant statistical difference amongst individual calibrants (Table 2). Results were in the optimal efficiency acceptance range of 90–110%, according to MIQE guidelines. The correlation coefficient (R2), demonstrating how well experimental data fit the regression line, was also observed in the acceptable average value of R2 ≥ 0.98. No significant statistical difference was observed between R2 values between the standard curve obtained from gDNA (R2 = 0.992) and pDNA (R2 = 0.996). The results with reasonable efficiency, good linearity, sensitivity and accuracy were observed for both standard curves, making them suitable as calibrants for the pvalb quantification. However, as expected, pDNA PCR efficiency was significantly better than the gDNA calibrator efficiency (p = 0.01). Pvalb is a significant allergen identified in fish products making it an essential gene target for quantification. Owing to the exponential nature of PCR amplification, minor differences in PCR efficiencies can generate more significant differences in copy number estimation [34]. This can have serious implications for the quantitative determination of allergens present in the food. As the amount of amplified DNA is proportional to the amount of allergen present in the sample, lower efficiency can result in inaccurate quantification and, consequently, non-compliance with regulations regarding allergen labeling. Therefore, pDNA calibrant with an efficiency of 100.64% appears more suited for quantification than gDNA.
Repeatability and reproducibility of qPCR assay using pDNA and gDNA standards
The repeatability and reproducibility of the qPCR assay were tested using linearised pGEM-T Easy pvalb pDNA and L. piscatorius gDNA as calibrators. As shown in Table 3, the results indicate that the assay has good repeatability with SD and bias values below 25% and within the ENGL acceptable range [35]. The results indicated that the pDNA calibrant was better than the gDNA calibrant in calculating the experimental copy numbers of β-pvalb. Thus, the qPCR assay employing the pGEM-T Easy pvalb calibrator is reliable and suitable for quantifying pvalb, and its performance is comparable to a gDNA calibrant.
The accuracy of the quantitative results was evaluated as the bias between the observed copy number and achieved value. The precision of the assay was assessed in terms of RSD. The RSD and bias values (Fig. 4) using plasmid calibrants were within the acceptable range of < 25% [35]. Higher RSD and bias values were observed with gDNA calibrants. RSD and bias values obtained in this study are similar to those previously reported [36,37,38] and demonstrated that the choice of the calibrant impacts the reliability and accuracy of the analysis. Observations in this study indicate that the constructed pGEM-T Easy pvalb was reliable and credible for quantifying β-pvalb. Our results indicate that gDNA calibrators tend to underestimate the pvalb content. Underestimation of the samples using gDNA calibrants is probably due to the low PCR efficiency of the gDNA calibrants compared to pDNA calibrants (Table 2). pDNA calibrants displayed better performance characteristics in terms of closeness to the expected value than their genomic counterparts (Fig. 4). This agrees with the superior performance characteristics associated with single and multiple target plasmid calibrants reported for the quantification of food allergens [38].
Determination of limit of detection (LOD) and limit of quantification (LOQ)
LOD and LOQ of qPCR assay are defined as the lowest quantity of the target gene that can be detected and quantified with more than 95% probability. To test the LOD and LOQ of plasmid pGEM-T Easy pvalb in the qPCR, fivefold dilutions of concentrations (100, 50, 25, 10 and 5 copies/μL) were prepared. According to ENGL [35], the acceptance criterion of LOD and LOQ should be less than 25 copies and 50 copies, respectively. In the assays, the results determined that the LOD and LOQ were 5 copies and 10 copies per reaction for pGEM-T Easy pvalb, whilst the LOD and LOQ of L. piscatorius gDNA were 10 copies and 25 copies per reaction, respectively. Both pGEM-T Easy pvalb and gDNA could be detected seven times in nine repeated reactions. LOD and LOQ are critical for evaluating the performance of analytical methods and instruments and ensuring that data are reliable and accurate. In many fields, including environmental analysis, food safety, and pharmaceuticals, regulatory agencies set minimum LOD and LOQ requirements for analytical methods to ensure accurate and meaningful results [38]. The high sensitivity of the assay indicates its suitability to quantify allergenic proteins, even in small amounts, which is important for detecting trace amounts of allergens in processed foods and meeting current global labelling legislations.
Short-term stability study of pGEM-T Easy pvalb
The stability of pDNA and gDNA standards stored at 4 °C and − 20 °C was tested for 60 days, standard curve construction was performed on the 0th, 15th, 30th and 60th day and PCR efficiency was compared. Plasmid DNA, pGEM-T Easy pvalb, showed PCR efficiency better than that of gDNA calibrants over a period of 60 days (Fig. 5). PCR efficiency of pDNA was within the acceptable range for 60 days at − 20 °C whereas PCR efficiency was within the acceptable range for 30 days at 4 °C. Similarly, gDNA standards were also stable for 60 days at − 20 °C, however, with a lower efficiency than pDNA standards. Also, at 4 °C, the standards showed some partial degradation with more than 110% PCR efficiency.
pDNA can be conveniently stored at − 20 °C and transported around the world in cold packs or dry ice. Whilst DNA degradation is expected during storage and transportation, an ideal reference material should be resistant to loss and degradation. The correlation coefficient (R2) showed a linear regression with values of ≥ 0.99 observed at − 20 °C for 60 days with no significant statistical variation, indicating a stable target with no dilution error. The results also suggest that the PCR assay could still detect and quantify a significant amount of pvalb, even after being stored for a prolonged period. This is important because it indicates that the sample was preserved in a way that allowed for the PCR to produce reliable results even after a significant amount of time had passed. This can be particularly useful in situations where the samples need to be stored for long periods before analysis, as it shows that the sample can be reliably preserved and used for PCR analysis later. These results are also in agreement with previously reported studies [16]. The results confirm that plasmid reference material can be stored for 60 days, increasing present knowledge of plasmid calibrant stability. Further, whilst we used linearised pDNA, non-linearised plasmids can also be used for 14 days at − 20 °C due to their high stability [39].
The advent of real-time qPCR has greatly improved the use of molecular biomarkers to diagnose and monitor human diseases, quantitative determination of GMO ingredients, and analysis of microbial communities [14, 40, 41]. The use of qPCR protocols may offer an advantage in quantifying potential allergens, although further evaluation is necessary to draw definitive conclusions. Fish species often contain both α- and β-pvalb, with multiple β-pvalb isoforms expressed by most species, exhibiting significant variation in amino acid composition and sequence [37, 42,43,44]. Such heterogeneity adds complexity to the diagnosis of fish allergy and the detection of allergenic parvalbumin, as an individual may have a stronger reaction to one β-pvalb isoform than another [37]. Our assay, hence, targeted the β-pvalb gene due to allergenic nature.
qPCR has become the favoured method of widespread use due to its reliability, high sensitivity, good reproducibility, a large dynamic range of quantification with a small amount of starting material, relatively low costs, and short analysis time [16, 45].
Absolute and relative quantification are two quantification strategies, each with advantages and disadvantages. Whilst the absolute method quantifies the concentration of the target gene by relating the Ct value to a standard curve, the relative method uses a reference sample with reference genes for quantification [46]. One of the significant drawbacks of using reference samples is that they cannot be normalised worldwide, resulting in a differences between inter-laboratories results. Hence, there is an effort to establish a standardised biomolecule calibrator approach between laboratories. This is often the case in immunodiagnostics, where some protein molecule plays the role of the standard as the calibrator [47]. Even though DNA-based diagnostics and detections took place in the first attempts to bring some interlaboratory standards, the International WHO standard for establishing the Epstein–Barr virus was announced in 2016 [48] Despite using cloned fragments of the virus as one of the alternative calibrators within a particular laboratory, whole-genome DNA of the EBV was used as the international standard. Regarding the scale of variance between laboratories, the context from EBV viral load determination, more than two orders difference between laboratories seems to be common in these assays [48]. To circumvent the limitations, quantification using plasmid calibrators is used. Whilst plasmid construction can be time-consuming, it is straightforward to reproduce once constructed. As our data highlighted, plasmid DNA can generate highly reproducible standard curves with high stability up to 60 days of storage. Due to this, pDNA are easy to distribute worldwide, normalising reference material.
The presented assay standardises PCR-based detection of L. piscatorius pvalb by introducing a plasmid standard. It provides an inevitable aid in substituting a calibrator based on DNA isolate from a particular specimen with a plasmid one. The variation, SD and RSD of obtained value between individual experiments are within one order, which is satisfactory in the context of interexperimental variance in other DNA-based qualitative assays. In the present study, we demonstrated using a plasmid calibrator to quantify the pvalb gene of L. piscatorius by cloning the target into a plasmid (pGEM-T Easy pvalb). We also compared the standard curve of both genomic and plasmid and demonstrated the stability of plasmid standards over 60 days.
Conclusion
The current work aimed to check the reliability of a plasmid-based calibrator for detecting and quantifying the β-pvalb gene in Lophius piscatorius. The developed plasmid was successfully cloned with our target gene (second intron of pvalb; 196 bp) and showed high efficiency, repeatability and stability. The plasmid DNA calibrator performed better compared with the gDNA calibrator. The study contributes to the increasing knowledge of the profound use of plasmid calibrators for quantitative detection. The alternate option of using a plasmid instead of isolated gDNA can be a helpful tool and a step towards standardising fish identification amongst laboratories. We have used L. piscatorius as a model organism. However, the results can be implemented and transferred to other organisms, establishing an essential tool in fish identification, and creating a database for the pvalb content of different fish species.
Data availability
The datasets generated during and/or analysed during the current study are available from the corresponding author upon reasonable request.
References
Zentilin L, Giacca M (2007) Competitive PCR for precise nucleic acid quantification. Nat Protoc 2:2092–2104. https://doi.org/10.1038/nprot.2007.299
Ballari RV, Martin A, Gowda LR (2013) A calibrator plasmid for quantitative analysis of insect resistant maize (yieldgard MON 810). Food Chem 140:382–389. https://doi.org/10.1016/j.foodchem.2013.02.067
Friedberg F (2005) Parvalbumin isoforms in zebrafish. Mol Biol Rep 32:167–175. https://doi.org/10.1007/s11033-005-2334-4
Berchtold MW, Epstein P, Beaudet AL, Payne ME, Heizmann CW, Means AR (1987) Structural organization and chromosomal assignment of the parvalbumin gene. J Biol Chem 262:8696–8701. https://doi.org/10.1016/s0021-9258(18)47470-4
Hansen TK (1995) Clinical reactivity to fish studied by multiple double-blind placebo-controlled food challenges (DBPCFC). J Allergy Clin Immunol 95:328
Helbling A, Haydel R Jr, McCants ML, Musmand JJ, El-Dahr J, Lehrer SB (1999) Fish allergy: is cross-reactivity among fish species relevant? Double-blind placebo-controlled food challenge studies of fish allergic adults. Ann Allergy Asthma Immunol 83:517–523. https://doi.org/10.1016/s1081-1206(10)62862-1
Helbling A, McCants ML, Musmand JJ, Schwartz HJ, Lehrer SB (1996) Immunopathogenesis of fish allergy: identification of fish-allergic adults by skin test and radioallergosorbent test. Ann Allergy Asthma Immunol 77:48–54. https://doi.org/10.1016/s1081-1206(10)63479-5
Pascual C, Martín Esteban M, Crespo JF (1992) Fish allergy: evaluation of the importance of cross-reactivity. J Pediatr 121:29–34. https://doi.org/10.1016/s0022-3476(05)81403-9
Aas K (1996) Studies of hypersensitivity to fish. Int Arch Allergy Immunol 30:190–208. https://doi.org/10.1159/000229805
Bernhiselbroadbent J, Scanlon S, Sampson H (1992) Fish hypersensitivity *1, *2I. In vitro and oral challenge results in fish-allergic patients. J Allergy Clin Immunol 89:730–737. https://doi.org/10.1016/0091-6749(92)90381-b
de Martino M, Novembre E, Galli L, de Marco A, Botarelli P, Marano E et al (1990) Allergy to different fish species in cod-allergic children: In vivo and in vitro studies. J Allergy Clin Immunol 86:909–914. https://doi.org/10.1016/s0091-6749(05)80154-x
Benedetto A, Abete MC, Squadrone S (2011) Towards a quantitative application of real-time PCR technique for fish DNA detection in feedstuffs. Food Chem 126:1436–1442. https://doi.org/10.1016/j.foodchem.2010.11.131
Lee C, Kim J, Shin SG, Hwang S (2006) Absolute and relative QPCR quantification of plasmid copy number in Escherichia coli. J Biotechnol 123:273–280. https://doi.org/10.1016/j.jbiotec.2005.11.014
Brankatschk R, Bodenhausen N, Zeyer J, Bürgmann H (2012) Simple absolute quantification method correcting for quantitative PCR efficiency variations for microbial community samples. Appl Environ Microbiol 78:4481–4489. https://doi.org/10.1128/AEM.07878-11
Mackay IM (2004) Real-time PCR in the microbiology laboratory. Clin Microbiol Infect 10:190–212
Taylor SC, Nadeau K, Abbasi M, Lachance C, Nguyen M, Fenrich J (2019) The ultimate qPCR experiment: producing publication quality, reproducible data the first time. Trends Biotechnol 37:761–774. https://doi.org/10.1016/j.tibtech.2018.12.002
Formisano-Tréziny C, de San FM, Gabert J (2012) Development of plasmid calibrators for absolute quantification of miRNAs by using real-time qPCR. J Mol Diagn 14:314–321. https://doi.org/10.1016/j.jmoldx.2012.02.008
Pfaffl MW, Hageleit M (2001) Validities of mRNA quantification using recombinant RNA and recombinant DNA external calibration curves in real-time RT-PCR. Biotechnol Lett 23:275–282
Pfaffl MW (2004) Quantification strategies in real-time PCR. AZ Quant PCR 1:89–113
Pfaffl MW (2019) Quantification strategies in real-time polymerase chain reaction. In: Polymerase chain reaction: theory and technology. Caister Academic Press, Poole
Boulter N, Suarez FG, Schibeci S, Sunderland T, Tolhurst O, Hunter T et al (2016) A simple, accurate and universal method for quantification of PCR. BMC Biotechnol 16:27. https://doi.org/10.1186/s12896-016-0256-y
Glick BR (2003). In: Glick BJ, Pasternak JJ (eds) Molecular biotechnology: principles and applications of recombinant DNA, 3rd edn. American Society for Microbiology, Washington, D.C
Khan S, Ullah MW, Siddique R, Nabi G, Manan S, Yousaf M et al (2016) Role of recombinant DNA technology to improve life. Int J Genomics 2016:2405954. https://doi.org/10.1155/2016/2405954
Woolfe M, Primrose S (2004) Food forensics: using DNA technology to combat misdescription and fraud. Trends Biotechnol 22:222–226. https://doi.org/10.1016/j.tibtech.2004.03.010
Dean D (1981) A plasmid cloning vector for the direct selection of strains carrying recombinant plasmids. Gene 15:99–102. https://doi.org/10.1016/0378-1119(81)90108-6
Lerner CG, Inouye M (1990) Low copy number plasmids for regulated low-level expression of cloned genes in Escherichia coli with blue/white insert screening capability. Nucleic Acids Res 18:4631. https://doi.org/10.1093/nar/18.15.4631
Padmanabhan S, Banerjee S, Mandi N (2011) Screening of bacterial recombinants: strategies and preventing false positives. In: Molecular cloning—selected applications in medicine and biology. InTech, Rijeka
Mukherjee S, Hanak P, Jilkova D, Musilova Z, Horka P, Lerch Z et al (2023) Simultaneous detection and quantification of two European anglerfishes by novel genomic primer. J Food Compost Anal. 115:104992. https://doi.org/10.1016/j.jfca.2022.104992
Untergasser A, Nijveen H, Rao X, Bisseling T, Geurts R, Leunissen JAM (2007) Primer3Plus, an enhanced web interface to primer3. Nucleic Acids Res 35:71–74. https://doi.org/10.1093/nar/gkm306
Biomatters, Geneious version 2022.1 (2023) Biomatters, Geneious version 2021.2. https://www.geneious.com. Accessed 6 Jan 2023
Li C, Wen A, Shen B, Lu J, Huang Y, Chang Y (2011) Fast cloning: a highly simplified, purification-free, sequence- and ligation-independent PCR cloning method. BMC Biotechnol. https://doi.org/10.1186/1472-6750-11-92
Klymus KE, Merkes CM, Allison MJ, Goldberg CS, Helbing CC, Hunter ME et al (2020) Reporting the limits of detection and quantification for environmental DNA assays. Environ DNA 2:271–282. https://doi.org/10.1002/edn3.29
Forootan A, Sjöback R, Björkman J, Sjögreen B, Linz L, Kubista M (2017) Methods to determine limit of detection and limit of quantification in quantitative real-time PCR (qPCR). Biomol Detect Quantif 12:1–6. https://doi.org/10.1016/j.bdq.2017.04.001
Svec D, Tichopad A, Novosadova V, Pfaffl MW, Kubista M (2015) How good is a PCR efficiency estimate: recommendations for precise and robust qPCR efficiency assessments. Biomol Detect Quantif 3:9–16. https://doi.org/10.1016/j.bdq.2015.01.005
European Network of GMO Laboratories (ENGL) (2015) Definition of minimum performance requirements for analytical methods for GMO testing. http://gmo-crl.jrc.ec.europa.eu/doc/MPR%20Report%20Application%2020_10_2015.pdf. Accessed 25 Sept 2022
Miyazaki A, Watanabe S, Ogata K, Nagatomi Y, Kokutani R, Minegishi Y et al (2019) Real-time PCR detection methods for food allergens (wheat, buckwheat, and peanuts) using reference plasmids. J Agric Food Chem 67(19):5680–5686. https://doi.org/10.1021/acs.jafc.9b01234
Houhoula D, Dimitriou P, Mengjezi G, Kyrana V, Lougovois V (2015) Quantification of parvalbumin in commercially important Mediterranean seafood species using real time PCR. Czech J Food Sci. 33(2):143–147. https://doi.org/10.17221/390/2014-cjfs
Luber F, Demmel A, Herbert D, Hosken A, Hupfer C, Huber I et al (2014) Comparative assessment of DNA-based approaches for the quantification of food allergens. Food Chem 160:104–111. https://doi.org/10.1016/j.foodchem.2014.03.077
Dhanasekaran S, Doherty TM, Kenneth J, TB Trials Study Group (2010) Comparison of different standards for real-time PCR-based absolute quantification. J Immunol Methods 354:34–39. https://doi.org/10.1016/j.jim.2010.01.004
Gandellini P, Profumo V, Folini M, Zaffaroni N (2011) MicroRNAs as new therapeutic targets and tools in cancer. Expert Opin Ther Targets 15:265–279. https://doi.org/10.1517/14728222.2011.550878
Caprioara-Buda M, Meyer W, Jeynov B, Corbisier P, Trapmann S, Emons H (2012) Evaluation of plasmid and genomic DNA calibrants used for the quantification of genetically modified organisms. Anal Bioanal Chem 404:29–42. https://doi.org/10.1007/s00216-012-6104-6
Mukherjee S, Bartoš O, Zdeňková K, Hanák P, Horká P, Musilova Z (2021) Evolution of the parvalbumin genes in teleost fishes after the whole-genome duplication. Fishes 6:70. https://doi.org/10.3390/fishes6040070
Mukherjee S, Horka P, Zdenkova K, Cermakova E (2023) Parvalbumin: a major fish allergen and a forensically relevant marker. Genes 14:223. https://doi.org/10.3390/genes14010223
Sun M, Liang C, Gao H, Lin C, Deng M (2009) Detection of parvalbumin, a common fish allergen gene in food, by real-time polymerase chain reaction. J AOAC Int 92:234–240. https://doi.org/10.1093/jaoac/92.1.234
Cermakova E, Lencova S, Mukherjee S, Horka P, Vobruba S, Demnerova K et al (2023) Identification of fish species and targeted genetic modifications based on DNA analysis: state of the art. Foods 12:228. https://doi.org/10.3390/foods12010228
Yu Y, Lee C, Kim J, Hwang S (2005) Group-specific primer and probe sets to detect methanogenic communities using quantitative real-time polymerase chain reaction. Biotechnol Bioeng 89:670–679. https://doi.org/10.1002/bit.20347
Klueber J, Costa J, Randow S, Codreanu-Morel F, Verhoeckx K, Bindslev-Jensen C et al (2020) Homologous tropomyosins from vertebrate and invertebrate: recombinant calibrator proteins in functional biological assays for tropomyosin allergenicity assessment of novel animal foods. Clin Exp Allergy 50:105–116. https://doi.org/10.1111/cea.13503
Fryer JF, Heath AB, Minor PD, Collaborative Study Group (2016) A collaborative study to establish the 1st WHO International Standard for human cytomegalovirus for nucleic acid amplification technology. Biologicals 44:242–251. https://doi.org/10.1016/j.biologicals.2016.04.005
Acknowledgements
The authors are obliged to Miroslav Švátora (Charles University, Prague, Czech Republic) for his help and advice concerning the morphological determination of fish samples.
Funding
Open access publishing supported by the National Technical Library in Prague. This research was financed by the Ministry of Agriculture of the Czech Republic, grant No. QK1910231 and Food research institutional support, MZE-RO0323. Morphological determinations were supported from project SVV-260434/2017—Integrative biology of animals (Charles University, Prague, Czech Republic).
Author information
Authors and Affiliations
Contributions
Conceptualization: SM, EC; methodology: SM, EC, PH and KZ; analyses: SM, EC, PHa and PHo; writing—original draft preparation: SM, EC, KZ and ZM; writing—review and editing: SM, KZ, DJ, PHa, PHo and ZM; supervision: PHa, PHo and KZ; project administration, PHa, KZ, PHo. All authors have read and agreed to the published version of the manuscript.
Corresponding author
Ethics declarations
Conflict of interest
The authors have no conflict of interest.
Compliance with ethics requirements
This article does not contain any studies with human participants or animals performed by any of the authors.
Informed consent
Informed consent was obtained from all individual participants included in the study.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Mukherjee, S., Hanak, P., Zdenkova, K. et al. Development of plasmid calibrators for absolute quantification of the β-parvalbumin gene in Lophius piscatorius. Eur Food Res Technol 249, 3165–3174 (2023). https://doi.org/10.1007/s00217-023-04357-z
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00217-023-04357-z