Skip to main content
Log in

Determination of trace elements in quartz glass by use of LINA-Spark–ICP–MS as a new method for bulk analysis of solid samples

  • Original paper
  • Published:
Analytical and Bioanalytical Chemistry Aims and scope Submit manuscript

Abstract

The determination of trace elements in pure quartz glass samples has been performed by coupling an ICP quadrupole mass spectrometer with the LINA-Spark-Atomizer, an IR laser ablation system dedicated to direct bulk and surface analysis of solid samples. Linear calibration curves were obtained for nine elements (Na, Al, Ca, Ti, Cr, Mn, Zr, Ba, and Pb) in the ng g–1 range with detection limits of less than 10 ng g–1 for Ca, Cr, Mn, Zr, Ba, and Pb and in the range of 120–220 ng g–1 for Na, Al, and Ti. The distance between the laser focal point and the sample surface has a significant influence on signal intensity and precision, both of which can be improved by a factor of approximately two by focusing the laser 15 mm behind the sample surface. Aerosol moistening reduced the standard deviation of the signal intensity by a factor of 2–4. Signal instability, which resulted from different ablation rates or variations in the transmission of the mass spectrometer, were compensated by use of the simultaneously measured SiAr+ ion as an internal standard. Under these conditions precision was usually better than 5% RSD. The results were compared with those obtained by use of a commercial LA–ICP–MS system. With this instrumentation linear calibration curves were achieved for three elements only (Al, Ti, and Pb), showing that LA–ICP–MS is less appropriate for bulk analysis in the ng g–1 range.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 14 December 2000 / Revised: 19 February 2001 / Accepted: 22 February 2001

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tibi, M., Heumann, K. Determination of trace elements in quartz glass by use of LINA-Spark–ICP–MS as a new method for bulk analysis of solid samples. Fresenius J Anal Chem 370, 521–526 (2001). https://doi.org/10.1007/s002160100789

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002160100789

Keywords

Navigation