Skip to main content
Log in

The reverse auto-compression system: a new type of column for preparative liquid chromatography

  • Original Paper
  • Published:
Analytical and Bioanalytical Chemistry Aims and scope Submit manuscript

Abstract

Axial compression of the stationary phase is an easy technique for packing preparative liquid chromatography columns. However, the compression piston often needs an important external device to move the external jack. A new type of column is described which uses an auto-compression system to move the piston and compress the packing material. The system is fitted with a new annular injector which is known to reduce the peak tailing. The results of the tests demonstrate the ease of use of this column, its efficiency and stability.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig 1.
Fig 2.
Fig 3.
Fig 4.
Fig 5A,B.
Fig 6.
Fig 7.
Fig 8.
Fig. 9A,B.
Fig. 10A–C.
Fig. 11A,B.
Fig. 12.
Fig. 13A,B.

Similar content being viewed by others

References

  1. Godbille E, Devaux P (1974) J Chromatogr Sci 12:564–569

    CAS  Google Scholar 

  2. Colin H, Hilaireau P, De Tournemire J (1990) LC-GC 8:302–304

    Google Scholar 

  3. Philippe–Venec L (1991) Thesis, Paris

  4. Knox JH, Laird GR, Raven PA (1976) J Chromatogr 122:129–145

    CAS  Google Scholar 

  5. Eon CH (1978) J Chromatogr 149:29–49

    CAS  Google Scholar 

  6. Farkas T, Sepaniak MJ, Guiochon G (1997) Am Inst Chem Eng J 43:1964–1974

    CAS  Google Scholar 

  7. Farkas T, Guiochon G (1997) Anal Chem 69:4592–4600

    CAS  Google Scholar 

  8. Broyles BS, Shalliker RA, Cherrak DE, Guiochon G (1998) J Chromatogr A 822:173–187

    CAS  Google Scholar 

  9. Shalliker RA, Broyles BS, Guiochon G (1999) J Chromatogr A 885:73–82

    Article  Google Scholar 

  10. Shalliker RA, Broyles BS, Guiochon G (1999) J Chromatogr A 865:83–95

    Article  CAS  PubMed  Google Scholar 

  11. Broyles BS, Shalliker RA, Guiochon G (2001) J Chromatogr A 917:1–22

    CAS  PubMed  Google Scholar 

  12. Brandt A, Mann G, Arlt W (1997) J Chromatogr A 769:109–117

    CAS  Google Scholar 

  13. Brandt A, Mann G, Arlt W (1998) J Chromatogr A 796:129–145

    Article  PubMed  Google Scholar 

  14. Dardoize F, Clodic G, Chevalet J (2001) LC/GC 14(10):634–635

  15. Dardoize F, Clodic G, Chevalet J (2002) Anal Bioanal Chem 372:817–821

    Article  CAS  PubMed  Google Scholar 

  16. Bristow PA (1978) J Chromatogr 149:13–28

    Article  CAS  Google Scholar 

  17. Neue UD (1997) HPLC columns. Wiley, New York

  18. Majors RE (1980) J Chromatogr Sci 18(9):393–486

    CAS  PubMed  Google Scholar 

  19. Guiochon G, Sarker M (1995) J Chromatogr A 704:247–268

    Article  CAS  Google Scholar 

  20. Sarker M, Guiochon G (1995) J Chromatogr A 709:227–239

    Article  CAS  Google Scholar 

  21. Stanley BJ, Sarker M, Guiochon G (1996) J Chromatogr A 741:175–184

    Article  CAS  Google Scholar 

  22. Guiochon G, Farkas T, Guan-Sajong H, Koh JH, Sarker M, Stanley B, Yun T (1997) J Chromatogr A 762:83–88

    CAS  PubMed  Google Scholar 

Download references

Acknowledgements

The authors acknowledge Precision Instruments (Marseille, France) for the financial support and the commercial development of the reverse auto-compression system.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to François Dardoize.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Dardoize, F., Clodic, G. & Chevalet, J. The reverse auto-compression system: a new type of column for preparative liquid chromatography. Anal Bioanal Chem 375, 112–119 (2003). https://doi.org/10.1007/s00216-002-1656-5

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00216-002-1656-5

Keywords

Navigation