Abstract
Recently, Asynchronous Motors are extensively used as workhorse in a multitude of industrial and high-performance applications. Induction Motors (IM) have wide applications in today’s industry because of their robustness and low maintenance. A smart and fast speed control system, however, is in most cases a prerequisite for most applications. This work presents a smart control system for IM using an Adaptive Fuzzy Logic Controller (AFLC) based on the Levenberg–Marquardt algorithm. A synchronously rotating reference frame is used to model IM. To achieve maximum efficiency and torque of the IM, speed control was found to be one of the most challenging issues. Indirect Field-Oriented Control (IFOC) or Indirect Vector Control techniques with robust AFLC offer remarkable speed control with high dynamic response. Computer simulation results using \(\hbox {MATLAB/Simulink}^{{\textregistered }}\) Toolbox are described and examined in this study for conventional PI and AFLC. AFLC presents robustness as regards overshoot, undershoot, rise time, fall time, and transient oscillation for speed variation of IFOC IM drive in comparison with classical PI. Moreover, load disturbance rejection capability for the designed control scheme is also verified with the AFL controller.
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00202-016-0447-5/MediaObjects/202_2016_447_Fig1_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00202-016-0447-5/MediaObjects/202_2016_447_Fig2_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00202-016-0447-5/MediaObjects/202_2016_447_Fig3_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00202-016-0447-5/MediaObjects/202_2016_447_Fig4_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00202-016-0447-5/MediaObjects/202_2016_447_Fig5_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00202-016-0447-5/MediaObjects/202_2016_447_Fig6_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00202-016-0447-5/MediaObjects/202_2016_447_Fig7_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00202-016-0447-5/MediaObjects/202_2016_447_Fig8_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00202-016-0447-5/MediaObjects/202_2016_447_Fig9_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00202-016-0447-5/MediaObjects/202_2016_447_Fig10_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00202-016-0447-5/MediaObjects/202_2016_447_Fig11_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00202-016-0447-5/MediaObjects/202_2016_447_Fig12_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00202-016-0447-5/MediaObjects/202_2016_447_Fig13_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00202-016-0447-5/MediaObjects/202_2016_447_Fig14_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00202-016-0447-5/MediaObjects/202_2016_447_Fig15_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00202-016-0447-5/MediaObjects/202_2016_447_Fig16_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00202-016-0447-5/MediaObjects/202_2016_447_Fig17_HTML.gif)
Similar content being viewed by others
References
Leonhard W (1996) Controlled AC drives, a successful transfer from ideas to industrial practice. Control Eng Pract 4(7):897–908
Fitzgerald AE, Kingsley CU, Stephen D (1990) Electric machinery, 5th edn. McGraw-Hill, New York
Marino R, Peresada S, Valigi P (1993) Adaptive input-output linearizing control of induction motors. IEEE Trans Autom Cont 38(2):208–221
Leonhard W (1985) Control of electrical drives. Springer-, Berlin
Heinemann G (1989) Comparison of several control schemes for ac induction motors. In: Proceedings of European Power Electronics Conference (EPE’89), pp 843–844
Bose BK (1984) Scalar decoupled control of induction motor. IEEE Trans Ind Appl IA–20(1):216–225
Jung J, Nam K (1998) A vector control schemes for EV induction motors with a series iron loss model. IEEE Trans Ind Electron 45:617–624
Blaschke F (1972) The principle of field orientation as applied to the new transvector closed-loop control system for rotating-field machines. Siemens Rev 34(5):217–219
Hasse K (1968) Zum Dynamischen Verhalten der Asynchronmachine bei Betrieb Mit Variabler Standerfrequenz und Standerspannung. ETZ-A 89:387–391
Boldea BL, Nasar SA (1992) Vector control of AC drives. CRC Press, Boca Raton
Zhang Y, Jiang Z, Yu X (July 2008) Indirect field-oriented control of induction machines based on synergetic control theory. In: Proceedings of the IEEE International Conferene on Power and Energy Society General, pp 20–24
Bose BK (1997) Power electronics and variable frequency drives. IEEE press standard publishers, New York
Krishnan R (2002) Electric motors drives modeling analysis and control. Publication Prentice Hall of India, Upper Saddle River
Lee C (1990) Fuzzy logic in control systems: fuzzy logic controller part 1. IEEE, New Delhi
Lee C (1990) Fuzzy logic in control systems: fuzzy logic controller part 2. IEEE, New Delhi
Kouzi K, Mokrani L, Nait-Said MS (2003) A new design of fuzzy logic controller with fuzzy adapted gains based on, indirect vector control for induction motor drive. In: IEEE proceedings of the 35th southeastern symposium on system theory, pp 362–366
Beierke S, Altrock C (1996) Fuzzy logic enhanced control of an induction motor with DSP. In: 5th IEEE international conference on fuzzy systems, New Orleans, LA
Spiegel RJ, Turner MW, McCormick VE (2003) Fuzzy sets and systems. Elsevier, New Jersey, pp 387–401
Krause P, Wasynczuk O, Sudhoff S (2002) Analysis of electric machinery and drive systems, 2nd edn. Wiley, New Jersey
Chee-Mun Ong (1998) Dynamic simulation of electric machinery using MATLAB/Simulink, 1st edn. Prentice Hall PTR, New Jersey
Wu B, Lang Y, Zargari N, Kouro S (2011) Power conversion and control of wind energy systems. Wiley, New Jersey
Eltamaly AM, Alolah AI, Basem MB (2010) Fuzzy Controller for Three Phases Induction Motor Drives. In: International conference on Autonomous and Intelligent Systems (AIS), pp 1-8
Pedrycez W (1989) Fuzzy control and fuzzy system. Wiley, New York
Wilamowski BM, Yu H (2010) Improved computation for Levenberg Marquardt training. IEEE Trans Neural Netw 21:930–937
Yu H, Wilamowski BM (2011) Levenberg-Marquardt Training. The Industrial Electronics Handbook- eng.auburn.edu, pp (12-1)–(12-16)
Wilamowski BM, Yu H (2010) Improved computation for Levenberg-Marquardt training. IEEE Trans Neural Netw 21(6):930–937
Huang YL, Lou HH, Gong JP, Edgar TF (2000) Fuzzy model predictive control. IEEE Trans Fuzzy Syst 8(6):665–678
Wang HO, Tanaka K, Griffin MF (2002) An approach to fuzzy control of nonlinear systems: stability and design issues. IEEE Trans Fuzzy Syst 4(1):14–23
Jeffrey T, Spooner, Kevin M (1996) Stable adaptive control Using fuzzy systems and neural networks. IEEE Trans Fuzzy Syst 4(3):339–359
Levenberg K (1994) A method for the solution of certain problems in least square. Q Appl Math 2:164–168
Marquardt D (1963) An algorithm for least-squares estimation of nonlinear parameters. Society Ind Appl Math J Appl Math 11:431–441
Harbour JP (2001) Evaluation and comparison of electric propulsion motors for submarines. Master dissertation, Massachusetts Institute of Technology. http://calhoun.nps.edu/handle/10945/10910
Bose BK (2002) Modern power electronics and AC drives. Prentice-Hall, Upper Saddle River
Betin F, Depermet D, Floczek P, Faqir A, Lanfranchi V, Pinchon D, Goeldel C, Capolino A (2001) Fuzzy logic scalar control for induction machine drive: comparison with classical drive. In: International AEGEAN conference on electrical machines and power electronics, pp 27–29
Gopakamur K, Sathiakumar S, Biswas SK, Vithayathil J (1984) Modified current source inverter fed induction motor drive with reduced torque pulsations. Proc Inst Elect Eng B 131(4):159–164
Krishnan R, Doran FC (1987) Study of parameter sensitivity in high performance and inverter-fed induction motor drive systems. IEEE Ind Appl IA–23(4):623–635
Mohan N (2001) Advance electric drives analysis, control and modeling using Simulink. MNPERE, Ney Jersey
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Zeb, K., Ali, Z., Saleem, K. et al. Indirect field-oriented control of induction motor drive based on adaptive fuzzy logic controller. Electr Eng 99, 803–815 (2017). https://doi.org/10.1007/s00202-016-0447-5
Received:
Accepted:
Published:
Issue Date: