Energy transfer on three-phase high-voltage lines: the strange behavior of the Poynting vector

  • Original Paper
  • Published:
Electrical Engineering Aims and scope Submit manuscript

Abstract

The energy transfer along three-phase high-voltage power lines will be analyzed using the Poynting vector. The result is somewhat strange: From a single-phase line it is well known that the time averaged Poynting vector vanishes at each point of the space in case of a pure reactive load since in that case no active power is transmitted. But in contrast, for three-phase lines, it comes out that there are regions in space where the time averaged Poynting vector does not vanish, not even in case of pure reactive loads, except the loads are balanced and the geometry of the line system is complete symmetrical. In detail it is shown that for an asymmetric but besides pure reactive load there are areas in space around the lines where active power is permanently transmitted in the direction to the loads whereas in other areas active power is permanently transmitted from the loads, i.e. in the direction to the generator. The paper discusses this surprising behavior and tries to give an explanation in terms of physics.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Feynman RP (2000) Feynman Vorlesungen über Physik, Band II: Elektromagnetismus und Struktur der Materie. Oldenbourg, Munchen, p 447

    Google Scholar 

  2. Jackson JD (2002) Klassische Elektrodynamik.. de Gruyter, Berlin, p 300

    Google Scholar 

  3. Koch H, Benato R (2008) Application of long high capacity gas-insulated lines in structures. CIGRE Technical Brochure No. 351, Paris

  4. 26. Verordnung zur Durchführung des Bundes-Immissionsschutzgesetzes (26. BImSchVO) vom 16.12.1996. Bundesgesetzblatt 1996 Teil I, Nr. 66 vom 20.12.1996

  5. Flosdorff R, Hilgarth G (2005) Elektrische Energieverteilung. Vieweg + Teubner, Stuttgart

    Google Scholar 

  6. Sommerfeld A (1961) Elektrodynamik. Akademische Verlagsgesellschaft, Leipzig

    MATH  Google Scholar 

  7. Feynman RP (2000) Feynman Vorlesungen über Physik. Band II: Elektromagnetismus und Struktur der Materie. Oldenbourg, Munchen, p 316, 531

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hartmut Grabinski.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Grabinski, H., Wiznerowicz, F. Energy transfer on three-phase high-voltage lines: the strange behavior of the Poynting vector. Electr Eng 92, 203–214 (2010). https://doi.org/10.1007/s00202-010-0176-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00202-010-0176-0

Keywords

Navigation