Abstract.
The adoption of an adequate methodology of analysis of permanent magnet (PM) tubular actuators allows one to formulate effectively the problem of improving their performance. A proper dimensioning strategy is then envisaged to increase the force density yielded by a tubular linear PM actuator. The strategy must be calibrated on the geometrical and mechanical constraints. This paper takes into consideration the most frequently adopted configurations of tubular actuators, presents a novel model and suggests two one-step design procedures.
Similar content being viewed by others
Author information
Authors and Affiliations
Additional information
Electronic Publication
Rights and permissions
About this article
Cite this article
Marignetti, .F., Scarano, .M. Comparative analysis and design criteria of permanent magnet tubular actuators. Electr Eng 84, 255–264 (2002). https://doi.org/10.1007/s00202-002-0127-5