Introduction

Anterior cruciate ligament (ACL) tear is a common injury in orthopaedic sports medicine [6]. Current techniques in ACL surgery have been associated with satisfactory long-term results in the majority of patients; however, there remains a subset, up to 30% of patients with unsatisfactory outcomes. Specifically, patients report difficulties relating to rotational instability and return to previous level of activity [2, 5, 11].

Techniques in ACL reconstruction have progressed over time. The double bundle technique, which aims at restoring the original anatomy of the ACL by reconstructing the anteromedial (AM) and posterolateral (PL) bundle of the ACL, is gaining popularity [8, 13, 17]. The double bundle structure is a commonly accepted model in describing and understanding ACL anatomy [7, 10]. Evaluating the double bundle structure and reconstruction of the ACL, one should consider anatomic aspects to provide guidelines for an anatomical reconstruction. One important point in ACL reconstruction is the placement of the femoral tunnels. The surgeon has to be aware of the location of both femoral insertion sites when arthroscopy is performed.

The aim of this study is to visualize the radiographic localization of the femoral insertion sites of each bundle with different angles of knee flexion on a lateral roentgenogram to get a better understanding of the double bundle structure in knee kinematics, because the visualization of the femoral attachment sites of both bundles changes with different degrees of knee flexion and does not seem to get enough consideration. We hypothesize that the centers of the AM and PL bundle are horizontally aligned when the knee is flexed beyond 90°.

Materials and methods

Four fresh-frozen cadaver knees (4 female) aged from 46 to 57 years with an average age of 51.5 years were used in this study. The specimens obtained had approximately 200 mm of femur and tibia. There were two left and two right knees. Skin, muscles, patella, patella tendon and the joint capsule were removed; however, the passive stabilizing structures of the joint, including the ACL, medial and lateral meniscus, and the collateral ligaments were left intact. A preparation of the ACL was completed to identify and separate the AM and PL bundles. The femoral insertion sites and the motion pattern of the AM and PL bundles were evaluated macroscopically. The bundles were painted with a radiopaque tantalum powder (325 mesh, Puratronic®, 99.97%, metals basis, Nb 50 ppm, Alfa Aesar® Company, Ward Hill, MA, USA). The femur and the tibia were each secured within custom-made cylinders using epoxy compound (Bondo, Bondo Corporation, Atlanta, GA, USA) and fixed to the testing system. A Robotic/Universal Force–Moment Sensor (UFS) Testing System consisting of a six-degree of freedom manipulator (PUMA Model 726; Unimate Inc., Danbury, CT), a UFS (Model 4015; JR3 Inc., Woodland, CA), and a computer that records joint kinematics was used throughout the study. The robotic manipulator was used to accurately determine the position of the femur with respect to the tibia. Lateral radiographs were obtained with a standard fluoroscope (Mini-View 6800, GE OEC Medical Systems Inc., Salt Lake City, Utah, USA) of each knee over the range of 0°–90° flexion in 30° increments to visualize the femoral insertion sites of both bundles.

The center of the radiographically marked femoral insertion was defined for each bundle on the lateral roentgenogram. The angle formed between a horizontal line and a line connecting the centre of the femoral insertion of each bundle at 0°, 30°, 60° and 90° of knee flexion was assessed (Fig. 1). For statistical analysis, we reported the ranges and the medians of our measurements.

Fig. 1
figure 1

Schema of angle measurement

Results

In all four knees, we were able to identify an ACL with an AM and PL bundle, which we divided surgically for better distinction. The femoral insertion site of the whole ACL was semilunar at the posterior part of the inner surface of the lateral condyle. The AM bundle originated from the anterior-proximal aspect and the PL bundle from the posterior-distal aspect of the femoral attachment with the leg in extension. The motion pattern demonstrated that the AM and PL bundles twist around each other as the knee is flexed toward 90°. The centre of the PL bundle visualized more anterior and distal than the centre of the AM bundle with the knee held in 90° flexion (Figs. 2, 3, 4, 5). The centers of the AM and PL bundle were horizontally aligned when the knee was flexed beyond 90°. The measurements of the angle between the line connecting the centres of the AM and PL insertion and a horizontal line demonstrate a decrease of the mean angle with increasing knee flexion toward 90° (Table 1).

Fig. 2
figure 2

Lateral radiograph at 0° of knee flexion

Fig. 3
figure 3

Lateral radiograph at 30° of knee flexion

Fig. 4
figure 4

Lateral radiograph at 60° of knee flexion

Fig. 5
figure 5

Lateral radiograph at 90° of knee flexion

Table 1 Angle measured between a horizontal line and the line connecting the centre of the femoral insertion of AM and PL bundle in the sagittal plane

Discussion

The most important finding of the present study was that the visualization of the femoral attachment sites of both bundles changes with different degrees of knee flexion and that the centers of the AM and PL bundle are horizontally aligned when the knee is flexed beyond 90°. As described in the literature, we found the orientation of the AM and PL bundle to be parallel in the sagittal plane with the knee at full extension, and twisted as the knee was flexed toward 90° [7, 12, 16]. This observation is a critical point for surgical considerations, because of the flexed knee position used during standard arthroscopy. Consistent with the existing literature, we found the femoral insertion site of the whole ACL to be semilunar at the posterior part of the inner surface of the lateral condyle [4, 10, 16]. The AM and PL bundle originated from the anterior-proximal and posterior-distal aspects of the femoral attachment. The AM bundle inserted anteromedially and the PL bundle posterolaterally, as previously reported [1, 3, 9]. This study reveals the importance of the correlation of knee flexion and femoral insertion site position. It is important to note that the anatomical description is given with the knee in full extension, while surgery is completed with the knee in flexion. With the knee in normal position for arthroscopy, flexion degrees between 70° and 90° are reached. In this position, the PL bundle is visualized anterior–distal to the AM bundle [14, 15]. Bending the knee beyond 90°, a more horizontal position of the bundles’ insertion sites is reached. The hypothesis was supported by our results. Although some authors used radiopaque wires or injected radiopaque contrast for imaging the ACL, the use of the radiopaque paint enabled us to visualize the whole ligament. This method was independent of variation in knee size or film-focus distance and reproducible.

Conclusion

The clinical relevance of this study is that the centers of the AM and PL bundle become horizontally aligned when the knee is flexed beyond 90°. The degree of knee flexion should be taken into account for femoral tunnel placement and for describing tunnel positioning.